SERVICE DIAGNOSIS

Increase size of line wiring.  Might also be the result of loose

connection indicated by excessive heating at the loose

connection terminal.

Check for overload on the tractor or undersized.

Check tractor governor.  Tight or defective throttle levers

and joints.

Worn or defective tractor engine 

(see engine manufacturers

check list.)

REMEDY

Back flash the 120 volt circuit with 12 volts DC

Replace grounded rotor assembly.

Repair or replace stator assembly.

Replace defective diode(s).

Clean and tighten generator and receptacle connections.

Clean screens, make sure interior of generator is unobstructed.

Readjust or Replace as required

Test and replace if defective.

Resync drive line halves.

Realign within 10 degrees.

Replace stator.  (Include generator model and serial number

on the order.)

Same as above.

Same as above.

Repair or replace as required

Test and replace if defective.

Low Speed

High line loss.  Indicated by lower voltage at load than at

generator terminals.

1.

Undersized/overloaded.

2.

Defective governor.

3.

Low power - worn engine.

LOW OUTPUT VOLTAGE

POSSIBLE CAUSE

Loss of residual magnetism.  Usually occurs only after

disassembly of field frame or severe mechanical stress/abuse.

Grounded or shorted rotor winding.

Open excitor circuit in stator

Defective diode(s) on rotor.

Broken or corroded connection.

NO OUTPUT VOLTAGE

Clogged ventilating inlet and/or outlet.

EXCESSIVE HEATING

Generator is spinning too fast, slow tractor down.

HIGH OUTPUT VOLTAGE

Shorted or grounded rotor coil.

VOLTAGE UNSTEADY/ LIGHTS FLICKERING

Drive line knuckles out of sync. (See Figure 5.)

PTO drive line alignment.

Shorted stator winding.  This can be identified by the use of an

internal  “growler” at a competent rewinding shop.

Grounded stator.  Check winding by test lamp or high potential

tester from stator leads to lamination.

Open stator circuit.  Measure circuit between leads with an

ohmmeter.  Should have a circuit between any pair of leads.

Defective stator

Defective Capacitors

Содержание W10PTOS/A

Страница 1: ...COMPACT SERIES TRACTOR DRIVE GENERATOR W10PTOS A...

Страница 2: ...ser vice when commercial power is interrupted inaccessible or impractical This PTO unit has a cast iron gear case with a 1 3 8 6 spline 540 rpm rated input shaft unit operating speed is 515 RPM and b...

Страница 3: ...r nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate 3 DEADLY EXHAUST GAS Exhaust fumes from any engine contain carbon monoxide an invisible odorless and deadly gas th...

Страница 4: ...and adjustment UNPACKING CAUTION Equipment Damage DO NOT invert generator during unpacking The Gearcase con tains oil which will leak out if inverted during unpacking Unpack the generator as follows...

Страница 5: ...ling bar C For safety the generator must be bolted to the three point hitch deck using all four mounting bolts B The foundation must be solid enough to absorb generator starting and reflected load tor...

Страница 6: ...INES FROM THE LOAD AND THE GENERATOR WHEN THE GEN ERATOR IS SUPPLYING POWER SEE FIGURE 6 Page 4 60706 180 0310 00 ELECTRICAL CONNECTIONS CAUTION Only qualified electricians should install electrical w...

Страница 7: ...OR TOO MUCH OIL CAN HARM THE EQUIPMENT See Lubrication portion of Main tenance for oil specifications Page 5 60706 180 0310 00 A properly rated and installed double throw manual power isolation transf...

Страница 8: ...e sure the drive shaft tumbling bar is assembled with its universal joint knuckles synchronized as illustrated in Figure 7 If knuckles are not synchronized the bar will chat ter when rotating which wi...

Страница 9: ...ING Equipment Damage DO NOT CLEAN THE GENERATOR WHILE IT IS RUNNING STORAGE MAINTENANCE If the generator is mounted on an off highway trailer such as the Winco trailer it should be stored in a garage...

Страница 10: ...t and replace if defective Low Speed High line loss Indicated by lower voltage at load than at generator terminals 1 Undersized overloaded 2 Defective governor 3 Low power worn engine LOW OUTPUT VOLTA...

Страница 11: ...11 3225 00 60706 241 ILLUSTRATED PARTS LIST COMPLETE ASSEMBLY...

Страница 12: ...w 7 300080 3 1 Top Cover 8 Z2568 1 Decal Danger PTO 9 300086 2 1 Drive Shaft Guard 10 98479 000 1 Decal Winco 1 11 53113 002 2 Decal Winco 12 63966 009 1 Nameplete 13 99841 003 1 Gear Case Support 14...

Страница 13: ...QTY DESCRIPTION 99839 002 1 Complete Generator End with Gear Case 19 54665 000 1 6205 2RS Bearing 26 300323 208 2 Varistor 27 300323 207 2 Diode 65 99839 112 1 45 mf Capacitor GENERATOR SPECIFICATIONS...

Страница 14: ...REF PART NUMBER QTY DESCRIPTION 1 300080 3 1 Top Cover 2 91286 001 1 20 Amp 1 Pole Circuit Breaker 3 63708 000 1 Ground Lug 4 57030 007 1 45 Amp 240 VAC Circuit Breaker 5 91370 000 1 Voltmeter 6 3000...

Страница 15: ...O WHEEL TRANSPORT DESCRIPTION PART NO 1 SUPPORT TONGUE QTY 2 300081 2 HITCH TONGUE QTY 2 300082 3 TONGUE 300083 4 AXLE QTY 2 300085 5 SUPPORT AXLE 300164 6 SUPPORT PTO SHAFT 300161 1 7 SUPPORT PTO SHA...

Страница 16: ...of incidental or consequential damages so that above limitation or exclusion may not apply to you This warranty gives you specific legal rights you may have other rights which vary from state to state...

Отзывы: