Winco W10000VE/A Скачать руководство пользователя страница 5

5

REV A

OMP-113

PREPARING THE UNIT 

UNPACKING

CAUTION: EQUIPMENT DAMAGE

THIS UNIT HAS BEEN SHIPPED WITH OIL. Failure to maintain the 

engine oil at the proper level will result in serious engine damage.

When you unpack your engine-generator set be sure to remove  all the 

information sheets and manuals from the carton.

1. As you receive your unit, it is critical to check it for any damage. If 

any damage is noted, it is always easiest to refuse the shipment and 

let WINCO take care of the freight claim. If you sign for the unit, the 

transfer of the ownership requires that you file the freight claim

2. Before proceeding with the preparations of your new generator 

for operation, take a couple of minutes to ensure the unit you have 

received is the correct model and review the specification pages in this 

manual to ensure that this unit meets your job requirements.

LUBRICATION

Before starting the engine, check that the crankcase has the proper 

level of a good quality oil. The recommended grade oil and quantity 

of oil required is listed in the engine operator’s manual and in the Oil 

Recommendations section of this manual. The engine normally holds 

2.4 to 2.5 quarts of oil. Use the dipstick (‘A’ in following image) to 

ensure that you have the correct amount of oil. The full oil level mark 

on the dipstick is depicted in the following image as ‘B’.

If needed, oil is added to the engine by removing the oil cap and adding 

oil at this point. After filling the crankcase to the proper level, be sure 

you properly tighten the oil fill cap (‘C’). 

NOTE: This engine generator must be on a level surface before you 

check or add oil to the system.

The necessity of using the correct oil and keeping the crankcase full 

cannot be overemphasized. Engine failures resulting from inadequate 

or improper lubricant are considered abuse and not covered by the 

generator or engine manufacturer’s warranty.

B

C

A

OIL RECOMMENDATIONS

Outdoor temperatures determine the proper oil viscosity for the 

engines. Use the chart to select the best viscosity for the outdoor 

temperature range expected.

OIL ALERT SYSTEM

This generator is equipped with a low oil shutdown system. This Briggs 

& Stratton engine uses an oil pressure switch system. If the system 

senses low oil pressure, it will automatically shut down the engine. This 

feature is designed to prevent costly repairs and downtime.

CAUTION: EQUIPMENT DAMAGE

Allowing the engine to shutdown repeatedly on low oil level may cause 

excessive wear which can be cumulative. 

GASOLINE

When using gasoline, always use fresh, clean, unleaded fuel. The 

engine is certified to operate on unleaded gasoline with a minimum 

octane rating of 87 or higher. Gasoline containing no more the 10% 

ethanol is acceptable.

CAUTION: EQUIPMENT DAMAGE

Do not use unapproved gasolines, such as E15 or E85. Do not mix 

oil in the gasoline. Use of unapproved fuels will damage the engine 

components and void the engine warranty.

Use of fuels with content of ethanol greater than shown above may 

cause starting and/or performance problems. Always ensure that the 

fuel is clean and free of all impurities.

WARNING: FIRE DANGER

Gasoline and its fumes are VERY explosive when proper precautions 

are not taken.

Never use gasoline that has been stored for an extended period of 

time as the fuel will lose its volatile properties and you will be left with 

varnish residue. The varnish like substance will clog the carburetor and 

will not burn properly.

The use of fuel additives, such as Sta-Bil, or an equivalent will minimize 

the formation of fuel gum deposits. If a unit has been out of operation 

for an extended period of time, it is best to drain old fuel from the 

engine and replace with fresh fuel before attempting to start.

See the engine manual for special instruction for operating this unit at 

over 5000 feet.

5

3110-00

60706-239

Self-exciting generators respond to severe overload-

ing differently than utility power.  When overloaded, 

the engine is not able to supply enough power to 

bring the electric motor up to operating speed.  The 

generator responds with high initial starting current, 

but the engine speed drops sharply.  The overload 

may stall the engine.  If allowed to operate at very low 

speeds, the electric motor starting winding will burn 

out in a short time.  The generator winding might also 

be damaged.

CAUTION:  EQUIPMENT DAMAGE

  RUNNING THE GENERATOR SET UNDER 

THESE CONDITIONS MAY RESULT IN DAMAGE 

TO THE GENERATOR STATOR AS WELL AS THE 

MOTOR WINDING.

The heavy surge of current required for starting mo-

tors is required for only an instant.  The generator will 

not be damaged if it can bring the motor up to speed 

in a few seconds of time.  If dif

culty is experienced in 

starting motors, turn all other electrical loads off and if 

possible reduce the load on the electric motor.

PREPARING THE UNIT

UNPACKING

CAUTION:  EQUIPMENT DAMAGE

    THIS UNIT HAS BEEN SHIPPED 

WITHOUT OIL.

Failure to maintain the engine oil at the proper level 

will result in serious engine damage.

When you unpack your new engine-generator set be

sure to remove all the information sheets and manu-

als from the carton.

1.  This generator-set was in good order when 

shipped.  Inspect the generator-set promptly after 

receiving it.  If any damage is noted, notify the trans-

portation company immediately; request proper pro-

cedures for 

ling a “concealed damage” claim.  Title 

to the equipment and responsibility for 

ling a claim 

rests with you when a generator-set is sent F.O.B. 

shipping point.  Only you can legally 

le a claim.

2.  Before proceeding with the preparations of your 

new generator-set for operation, take a couple of 

minutes to insure the unit you have received is the 

correct model and review the speci

cation pages in 

this manual to insure that this unit meets your job 

requirements.

LUBRICATION

Before starting the engine, 

ll the crankcase to the 

proper level with a good quality oil.  The recommend-

ed grade of oil and quantity of oil required is listed in 

the engine operator’s manual and under the service 

tab in this manual.  This unit was shipped with most 

of the oil removed.  The engine normally holds 2.4 to 

2.5 quarts of oil.  Since there is some trapped oil in 

the engine, when 

lling the crankcase the 

rst time 

use the dipstick (ref “A”) to ensure that you do not 

over

ll the crankcase. Reference “B” shows the full 

oil level mark on the dipstick.

Oil is added to the engine by removing the oil 

ll cap 

(ref “C”) and adding oil at this point.  After 

lling the 

crankcase to the proper level, be sure you properly 

tighten the oil 

ll cap.  NOTE:  This engine generator 

must be on a level surface before you check or add 

oil to the system. 

The necessity of using the correct oil, and keep-

ing the crankcase full cannot be overemphasized.

Engine failures resulting from inadequate or improper 

lubricant are considered abuse and not covered by 

the generator or engine manufacturer’s warranty. 

Oil Recommendations 

Outdoor temperatures determine the proper oil vis-

cosity for the engines. Use the chart to select the best 

viscosity for the outdoor temperature range expected. 

A

C

A

B

SAE

30

10W-

30

Synthetic

5W-

30

5W-

30

°

F

°

C

Содержание W10000VE/A

Страница 1: ...WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com INSTALLATION AND OPERATORS W10000VE A GENERATOR MANUAL...

Страница 2: ...quality precision engineered generator designed and tested to give you years of satisfactory service To get the best performance from your new generator it is important that you carefully read and fo...

Страница 3: ...nsible person A Do not allow anyone to operate the generator without proper instruction B Guard against electric shock C Avoid contact with live terminals or receptacles D Use extreme care if operatin...

Страница 4: ...ent amps to start them than to run them Some motors particularly low cost split phase motors are very hard to start and require 5 to 7 times as much starting current as running current Capacitor motor...

Страница 5: ...l level may cause excessive wear which can be cumulative GASOLINE When using gasoline always use fresh clean unleaded fuel The engine is certified to operate on unleaded gasoline with a minimum octane...

Страница 6: ...For your safety always connect the positive battery cable to the bat terminal first Then connect the negative battery cable to the bat terminal Make sure all connections are clean an tight Reverse the...

Страница 7: ...Rotate the key switch C briefly to the START position Repeat if necessary NOTE The starter life is improved by using shorter cycles with time to cool off between cranking cycles Do NOT operate the sta...

Страница 8: ...ING THE LOADS Allow the engine to warm up for two or three minutes before applying any load This will allow the engine to reach normal operating temperature and oil to circulate throughout the engine...

Страница 9: ...N EQUIPMENT DAMAGE Failure to properly limit and balance the load applied to the generator will cause the generator to produce low voltage and may damage the engine generator set It may also cause sev...

Страница 10: ...t with fresh clean oil e Install the oil lter by hand until the gasket contacts the oil lter adapter then tighten the oil lter 1 2 to 3 4 turns f Replace oil drain plug g Remove oil ller plug and re l...

Страница 11: ...rwise damaged replace it Using damaged or cracked receptacles can be both dangerous to the operator and destructive to the equipment CLEANING Remove dirt and debris with a cloth or brush DO NOT use hi...

Страница 12: ...e consumables or labor This warranty does not cover travel time mileage or labor for removal or re installation of WINCO product from its application Normal wear and tear Costs of rental equipment WIN...

Отзывы: