INTRODUCTION

INTENDED USES

This engine generator set has been designed primarily for portable 

heavy duty commercial use. Both 120 volt and 240 volt receptacles 

are provided in the control panel to plug in your loads (lights, portable 

tools, and small appliances). These units are dual wound generators, 

therefore the 120 volt loads must be equally split with 1/2 of the rated 

capacity available on each of the two 120 volt circuits.

This portable unit requires large quantities of fresh air for cooling the 

engine and generator. For safety, long life and adequate performance, 

these units should never be run in small compartments without positive 

fresh air flow.

RESTRICTED USES

DO NOT 

remove from the cradle assembly. Removal of the generator 

from the cradle assembly may cause excessive vibration and damage 

to the engine-generator set.

DO NOT

 install and operate this generator in a small compartment, 

i.e. generator compartments of vehicles, motor homes or travel 

trailers. These compartments will not allow enough free flow of fresh 

air to reach the engine generator set for cooling and will cause the 

unit to overheat, damaging both the engine and generator. Small 

compartments will also develop hot spots where there is very little air 

flow and may cause a fire.

PLEASE NOTE:

 There are 3rd party companies making enclosures for 

generators that have been properly engineered. The use of these 3rd 

party enclosures is acceptable as long as they have been certified and 

meet current code.

DO NOT 

attempt to operate at 50 cycles. These units are designed and 

governed to operate at 60 cycles only.

UNIT CAPABILITIES

GENERATOR CONNECTIONS

W10000VE/A: 120 Volt and 240 Volt receptacles are provided for 

connection to various loads. The diagram below represents this 9,600 

watt (rated output) generator. A & B represent the 120 volt output legs 

of this generator. Up to 4,800 watts at 120 volts (40 Amps) can be 

drawn from the receptacles attached to either A or B output legs. This 

generator is capable of producing 40 Amps of 240 volt current at C. 

Check the appliance or tool nameplates for the current and voltage to 

insure compatibility. Remember that power taken from C reduces the 

power available at equally both A and B and vice versa.

STARTING ELECTRIC MOTORS

Electric motors require much more current (amps) to start them than to 

run them. Some motors, particularly low cost split-phase motors, are 

very hard  to start and require 5 to 7 times as much starting current as 

running current. Capacitor motors are easier to start and usually require 

2 to 4 times as much starting current as running current. Repulsion 

Induction motors are the easiest to start and require only 1 1/2 to 2 1/2 

times as much starting as running current.

Most fractional horsepower motors take about the same amount 

of current to run them whether they are Repulsion Induction (RI), 

Capacitor (Cap), or Split-Phase (SP) type.

If the electric motor is connected to a hard starting load such as an air 

compressor, it will require more starting current. If it is connected to a 

light load, or no load such as a power saw, it will require less starting 

current. The exact requirement will also vary with the brand or design 

of the motor.

Self-exciting generators respond to severe overloading differently than 

utility power. When overloaded, the engine is not able to supply enough 

power to bring the electric motor up to operating speed. The generator 

responds with high initial starting current, but the engine speed drops 

sharply. The overload may stall the engine. If allowed to operate at very 

low speeds, the electric motor starting winding will burn out in a short 

time. The generator winding might also be damaged.

CAUTION: EQUIPMENT DAMAGE

Running the generator set under these conditions may result in 

damage to the generator stator as well as the motor winding.

The heavy surge of current required for starting motors is required for 

only an instant. The generator will not be damaged if it can bring the 

motor up to speed in a few seconds of time. If difficulty is experienced 

in starting motors, turn all other electrical loads off and if possible 

reduce the load on the electric motor.

6. SERVICING EQUIPMENT -

All service, including the installation or replacement of service parts, 

should be performed only by a qualified technician.

 

A. Use only factory approved repair parts.

 

B. Do not work on this equipment when fatigued.

 

C. Never remove the protective guards, covers, or receptacle 

 

  panels while the engine is running.

 

D. Use extreme caution when working on electrical components. 

 

  High output voltage from this equipment can cause serious 

 

  injury or death.

 

E. Always avoid hot mufflers, exhaust manifolds, and engine parts. 

 

  They can cause severe burns instantly.

 

F. The use of the engine-generator set must comply with all  

 

  national, state, and local codes.

Содержание W10000VE/A

Страница 1: ...WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com INSTALLATION AND OPERATORS W10000VE A GENERATOR MANUAL...

Страница 2: ...quality precision engineered generator designed and tested to give you years of satisfactory service To get the best performance from your new generator it is important that you carefully read and fo...

Страница 3: ...nsible person A Do not allow anyone to operate the generator without proper instruction B Guard against electric shock C Avoid contact with live terminals or receptacles D Use extreme care if operatin...

Страница 4: ...ent amps to start them than to run them Some motors particularly low cost split phase motors are very hard to start and require 5 to 7 times as much starting current as running current Capacitor motor...

Страница 5: ...l level may cause excessive wear which can be cumulative GASOLINE When using gasoline always use fresh clean unleaded fuel The engine is certified to operate on unleaded gasoline with a minimum octane...

Страница 6: ...For your safety always connect the positive battery cable to the bat terminal first Then connect the negative battery cable to the bat terminal Make sure all connections are clean an tight Reverse the...

Страница 7: ...Rotate the key switch C briefly to the START position Repeat if necessary NOTE The starter life is improved by using shorter cycles with time to cool off between cranking cycles Do NOT operate the sta...

Страница 8: ...ING THE LOADS Allow the engine to warm up for two or three minutes before applying any load This will allow the engine to reach normal operating temperature and oil to circulate throughout the engine...

Страница 9: ...N EQUIPMENT DAMAGE Failure to properly limit and balance the load applied to the generator will cause the generator to produce low voltage and may damage the engine generator set It may also cause sev...

Страница 10: ...t with fresh clean oil e Install the oil lter by hand until the gasket contacts the oil lter adapter then tighten the oil lter 1 2 to 3 4 turns f Replace oil drain plug g Remove oil ller plug and re l...

Страница 11: ...rwise damaged replace it Using damaged or cracked receptacles can be both dangerous to the operator and destructive to the equipment CLEANING Remove dirt and debris with a cloth or brush DO NOT use hi...

Страница 12: ...e consumables or labor This warranty does not cover travel time mileage or labor for removal or re installation of WINCO product from its application Normal wear and tear Costs of rental equipment WIN...

Отзывы: