WINCO INC. 225 S. CORDOVA AVE. LE CENTER, MN 56057 507-357-6821
SERVICE DEPT. 507-357-6831
www.wincogen.com
INSTALLATION AND
OPERATORS
W10000VE/A
GENERATOR
MANUAL
Страница 1: ...WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com INSTALLATION AND OPERATORS W10000VE A GENERATOR MANUAL...
Страница 2: ...quality precision engineered generator designed and tested to give you years of satisfactory service To get the best performance from your new generator it is important that you carefully read and fo...
Страница 3: ...nsible person A Do not allow anyone to operate the generator without proper instruction B Guard against electric shock C Avoid contact with live terminals or receptacles D Use extreme care if operatin...
Страница 4: ...ent amps to start them than to run them Some motors particularly low cost split phase motors are very hard to start and require 5 to 7 times as much starting current as running current Capacitor motor...
Страница 5: ...l level may cause excessive wear which can be cumulative GASOLINE When using gasoline always use fresh clean unleaded fuel The engine is certified to operate on unleaded gasoline with a minimum octane...
Страница 6: ...For your safety always connect the positive battery cable to the bat terminal first Then connect the negative battery cable to the bat terminal Make sure all connections are clean an tight Reverse the...
Страница 7: ...Rotate the key switch C briefly to the START position Repeat if necessary NOTE The starter life is improved by using shorter cycles with time to cool off between cranking cycles Do NOT operate the sta...
Страница 8: ...ING THE LOADS Allow the engine to warm up for two or three minutes before applying any load This will allow the engine to reach normal operating temperature and oil to circulate throughout the engine...
Страница 9: ...N EQUIPMENT DAMAGE Failure to properly limit and balance the load applied to the generator will cause the generator to produce low voltage and may damage the engine generator set It may also cause sev...
Страница 10: ...t with fresh clean oil e Install the oil lter by hand until the gasket contacts the oil lter adapter then tighten the oil lter 1 2 to 3 4 turns f Replace oil drain plug g Remove oil ller plug and re l...
Страница 11: ...rwise damaged replace it Using damaged or cracked receptacles can be both dangerous to the operator and destructive to the equipment CLEANING Remove dirt and debris with a cloth or brush DO NOT use hi...
Страница 12: ...e consumables or labor This warranty does not cover travel time mileage or labor for removal or re installation of WINCO product from its application Normal wear and tear Costs of rental equipment WIN...