OMP-132/D

SPECIFICATIONS

GENERATOR

Model 

     W10000VE/B

       W10000VE-03/A

Surge 

Watts 

    10,000

Continuous 

Watts 

  9,600

Volts      120/240

Amps 

     80/40

Generator Manufacturer  

Mecc Alte   

Generator Model Number  ES20F-160

Part 

Number    16346-025 

Rotor 

Resistance 

   6.5 

Ohms

Stator Resistance 

 

 

0.124 Ohms

Regulation 

    AVR

ENGINE

Engine Manufacturer 

 

Briggs & Stratton

Engine Model Number   

543477

Type 

Code    0614-G1

Spark Plug Gap   

 

 

0.030 in

Intake Valve Clearance   

0.007 - 0.0 in

Exhaust Valve Clearance  

0.004 - 0.006 in

Oil Capacity  

 

 

 

2.4-2.5 qts (78-80 oz)

TESTING POLICY

Before any generator is shipped from the factory, it is fully 

checked for performance. The generator is loaded to its 

full capacity, and the voltage, current, and frequency are 

carefully checked.

Rated output of generator is based on engineering tests 

of typical units, and is subject to, and limited by, the 

temperature, altitude, fuel, and other conditions specified 

by the manufacturer of applicable engines.

Содержание W10000VE-03/A

Страница 1: ...to contact us concerning this unit it will help us to respond to your needs faster MODEL _________________________________________________ SERIAL NUMBER _________________________________________ PURC...

Страница 2: ...NG THE GENERATOR GENERATOR MAINTENANCE CLEANING TROUBLESHOOTING 14 RECEPTACLE WIRING DIAGRAM 15 36 MONTH LIMITED WARRANTY 16 CA EMISSION CONTROL WARRANTY 16 SAVE THESE INSTRUCTIONS This manual contain...

Страница 3: ...ype Code 0614 G1 Spark Plug Gap 0 030 in Intake Valve Clearance 0 007 0 0 in Exhaust Valve Clearance 0 004 0 006 in Oil Capacity 2 4 2 5 qts 78 80 oz TESTING POLICY Before any generator is shipped fro...

Страница 4: ...HAZARD Gasoline and other fuels present a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke or...

Страница 5: ...s can be drawn from the receptacles attached to either A or B output legs This generator is capable of producing 40 Amps of 240 volt current at C Check the appliance or tool nameplates for the current...

Страница 6: ...h can be cumulative GASOLINE When using gasoline always use fresh clean unleaded fuel The engine is certified to operate on unleaded gasoline with a minimum octane rating of 87 or higher Gasoline cont...

Страница 7: ...he negative battery cable to the bat terminal Make sure all connections are clean an tight Reverse the sequence when disconnecting disconnect the negative cable first These engines produce enough dire...

Страница 8: ...urs 100 hours 100 hours CHOKE RUN COMMERCIAL POWER BRIGGS STRATTON TM R NOTE The starter life is improved by using shorter cycles with time to cool off between cranking cycles Do NOT operate the start...

Страница 9: ...at to do contact a competent professional to assist you The NFPA 70 250 34 35 are good technical references STANDARD PORTABLE GENERATOR Your WINCO portable generator ships with a bonded neutral You ca...

Страница 10: ...operation of motors lights and most appliances However electronic equipment and clocks will be affected if correct RPM is not maintained See Load vs Output chart Although individual units and models v...

Страница 11: ...Meter when applying load This will ensure the generator is balanced Balanced Unbalanced 120 Volt and 240 Volt receptacles are provided for connection to various loads The diagram below represents thi...

Страница 12: ...ngines Gasoline for the closest engine repair center or ask the dealer from whom you purchased the power plant 1 Change the oil after the rst 5 hours of operation and yearly or 100 hours thereafter un...

Страница 13: ...r y under Engines Gasoline epair center or ask the dealer sed the power plant r the rst 5 hours of operation s thereafter under normal op ange engine oil every 50 hours ne is operated under heavy t te...

Страница 14: ...it be needed in an emergency GENERATOR MAINTENANCE Any major generator service including the installation or replacement of parts should be performed only by a qualified electrical service technician...

Страница 15: ...15 OMP 132 D RECEPTACLE WIRING DIAGRAM G2 G2 G1 GND GND GND GND GND N N N N N G1 G1 G1 G1 G1 G1 G2 G2 G2 G2 G2...

Страница 16: ...nd Purchaser s sole remedy for a failure under this warranty shall be limited to the repair of the product At WINCO s option material found to be defective in material or workmanship under normal use...

Отзывы: