PERMANENTLY INSTALLED GENERATORS

This WINCO portable generator ships with a bonded 

neutral and overcurrent protection. NFPA 70 refers to this 

as a “separately derived system.” When connecting it to a 

building a transfer switch specifically designed for GFCI and 

bonded neutral generators is required. 

WIRING

Plug your tools such as drills, saws, blowers, sump pump, 

and other items to be powered directly into the generator 

receptacles. Before plugging in all the tools and cord 

sets, recheck the rating of the generator set. Be sure it 

can handle the intended load and is compatible with the 

voltage, phase, and current ratings. ‘Hard wiring’ this unit 

directly into a temporary construction site electrical system is 

NOT A SIMPLE DO-IT-YOURSELF JOB. 

For your safety, all 

wiring must be done by a qualified electrician and conform 

to the National Electric Code and comply with all state and 

local codes and regulations. Check with local authorities 

before proceeding.

WARNING: PERSONAL DANGER

A fully isolated, double pole double throw manual 

transfer switch must be installed any time a generator 

is being connected to an existing distribution system.

 

1. These engine-generator sets are designed for 

 

  portable residential and light commercial use.  

 

  Receptacles are provided on the control panel to 

 

  permit 120 and 240 Volt portable appliances and 

 

  tools to be plugged directly into them. Please note 

 

  that the 3-wire 240 Volt receptacle(s) on these units 

 

  are designed to power only 240 Volt tools. There 

 

  are two hot leads and a ground wire, but no neutral 

 

  connection, in the 3-wire 240 Volt receptacle. 

 

  A 4-wire receptacle (two hot, one ground, and 

 

  one neutral) has been provided on the control panel 

 

  for use in temporary power applications requiring 

 

  120/240 Volt power. Consult a licensed electrician for 

 

  wiring the  TemPower plug and connecting it as 

 

  temporary service.

 

  To connect these units directly to an un-powered, 

 

  isolated construction site TemPower panel, have your 

 

  electrician connect to the control panel  using a 

 

  120/240 Volt, 4-wire twist-lock plug (L14-30).

 

2. If the generator set is connected to an existing 

 

  distribution system, a fully isolated manual transfer 

 

  switch must be installed. The transfer switch prevents 

 

  damage to the generator and the other circuit 

 

  components if main line power is restored while the 

 

  generator is connected. Installing a transfer switch 

 

  also permits the use of normal fusing.

 

3.Many homes and construction sites are wired for at 

 

  least 60 to 100 Amp entrance service, much greater 

 

  than the capacity of this portable generator. When 

 

  installing the generator at these sites, a secondary 

 

  emergency distribution panel may have to be 

 

  installed. The emergency distribution panel must be 

 

  installed by a licensed electrician according to all 

CONNECTING THE LOADS

APPLYING THE LOADS

Allow the engine to warm up for two or three minutes 

before applying any load. This will allow the engine to 

reach normal operating temperature and oil to circulate 

throughout the engine. A shot warm-up time will permit 

the engine to work more efficiently when the load is 

applied and will reduce the wear in the engine, extending 

its life.

Receptacles have been provided to allow loads to be 

connected to the generator. The loads should be added 

one at a time. If a large motor is being started: or multiple 

motors are being started, they should be started individually 

and the largest should be started first.

CAUTION: EQUIPMENT OVERLOAD

Keep the generator load within in the generator and 

receptacle nameplate rating. Overloading may cause 

damage to the generator and/or the loads.

Most electric tools and appliances will have the voltage and 

amperage requirements on their individual nameplates. 

When in doubt, consult the manufacturer or a local 

electrician. The nameplate amperage rating for electric 

motors can be misleading. See “Starting Electric Motors” in 

the Unit Capabilities. 

These engine-generator sets are inherently self regulating 

based on engine speed. The engine governor will 

automatically adjust itself to the load. No harm to 

the generator will result if it is operated with no load 

connected. Proper utilization of the receptacles located on 

the control panel is necessary to prevent damage to either 

the receptacles or the generator. The generator is a limited 

source of electrical power, therefore, pay special attention 

to the receptacle and generator ratings. The nameplate 

rating can be obtained through a single receptacle as long 

as the receptacles amperage rating is not exceeded.

GROUNDING

Proper grounding of your generator is application 

dependent. Carefully evaluate your planned use of your 

generator to understand which grounding you require. 

If you are not sure what to do, contact a competent 

professional to assist you. The NFPA 70 250:34-35 are good 

technical references.  

STANDARD PORTABLE GENERATOR

Your WINCO portable generator ships with a bonded 

neutral. You can safely use this generator without external 

grounding as long as all loads are powered through the 

receptacle panel. 

VEHICLE-MOUNTED GENERATOR

Your WINCO portable generator ships with a bonded 

neutral. When mounted to a vehicle to safely distribute 

power it is necessary that the generator frame is bonded 

to the vehicle frame. The generator should only supply 

equipment that is cord and plug connected through 

receptacles mounted on the generator or the vehicle. 

Содержание HPS6000HE/I

Страница 1: ...ber as yours If you should ever need to contact us concerning this unit it will help us to respond to your needs faster MODEL _________________________________________________ SERIAL NUMBER _________________________________________ PURCHASE DATE _________________________________________ DEALER NAME ___________________________________________ DEALER PHONE ________________________________________ ...

Страница 2: ...SPARK PLUG CARBON CANISTER GENERATOR CARE 18 EXERCISING THE GENERATOR GENERATOR MAINTENANCE CLEANING TROUBLESHOOTING 18 RECEPTACLE WIRING DIAGRAM 19 CA EVAP EMISSION CONTROL 20 LIMITED WARRANTY 20 SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the generator Read and understand all instructions in the manual before ...

Страница 3: ...turer Mecc Alte Spa Generator Model Number S16W 130 A Part Number 16346 006 Rotor Resistance 3 95 Ohms Stator Resistance 0 36 Ohms Cap Winding Resistance 2 45 Ohms Capacitors 25 mF Capacitor Part Number 16346 612 ENGINE Engine Manufacturer Honda Engine Model Number GX340 Type RT2VWE2 Code GCBET Spark Plug Gap 0 030 in Intake Valve Clearance 0 006 0 010 in Exhaust Valve Clearance 0 010 0 012 in Oil...

Страница 4: ...the earth 2 FIRE HAZARD Gasoline and other fuels present a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke or use open flame near the generator set or fuel tank D Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate E Store fuel only in a...

Страница 5: ...ds The diagram below represents this 5 500 watt rated output generator A B represent the 120 volt output legs of this generator Up to 2 250 watts at 120 volts 22 9 Amps can be drawn from the receptacles attached to either A or B output legs This generator is capable of producing 22 9 Amps of 240 volt current at C Check the appliance or tool nameplates for the current and voltage to insure compatib...

Страница 6: ...el This engine is certified to operate on unleaded gasoline with a minimum octane rating of 87 or higher Gasoline containing no more than 10 ethanol is accepted CAUTION EQUIPMENT DAMAGE Do not use unapproved gasolines such as E15 or E85 Do NOT mix oil in the gasoline Use of unapproved fuels will damage the engine components and void the engine warranty Use of fuels with content of ethanol greater ...

Страница 7: ... with your local fuel supplier to ensure complete compliance with ALL codes 1 Remove the plastic cover plug from the demand regulator 2 Connect the flex fuel line to the demand regulator or the optional solenoid A positive fuel shut off device must be installed in the fuel line close to the engine generator set This manual shut off valve is required by code even if the 12 Volt fuel solenoid kit is...

Страница 8: ...onnect the ridged mounted pipe directly 6 Turn on the vapor fuel 7 Start the engine 8 Apply the load to the generator NG TO GASOLINE 1 With the engine running turn off the NG fuel supply 2 Run the engine until it runs out of fuel 3 Remove the flexible fuel line from the demand regulator 4 Reinstall the plastic insert in the regulator 5 Check to be sure the gasoline fuel valve is off 6 Fill the gas...

Страница 9: ...nect the positive battery cable to the bat terminal first Then connect the negative battery cable to the bat terminal Make sure all connections are clean and tight Reverse the sequence when disconnecting disconnect the negative cable first The engines produce enough direct current to keep the battery charged under normal operating conditions but were not intended to be used as a battery charger WA...

Страница 10: ...low a certain point the low oil module on the engine will shut it down This oil warning system will automatically stop the engine before the oil level reaches a critical danger point This feature is designed to prevent costly repairs and downtime CAUTION EQUIPMENT DAMAGE Allowing the engine to shutdown repeatedly on low oil level may cause excessive wear which can be cumulative ...

Страница 11: ...rip lightly until resistance is felt then pull briskly 6 When the engine starts open the choke gradually 7 The engine should promptly come up to operating speed NOTICE Do not allow the starter grip to snap against the en gine Return it gently to prevent damage to the starter CAUTION EQUIPMENT DAMAGE Never permit the choke to remain on after the engine has run for a short time It is not necessary t...

Страница 12: ... Because the engine vacuum needs to activate the fuel system it is almost impossible to manual start the unit using NG 1 Check oil level refill as needed 2 Turn on the NG fuel supply 3 NEVER use the choke when operating on NG 4 Turn the engine switch to the on position 5 Operating the starter Rotate the key switch briefly to START position The starter life is improved by using shorter starting cyc...

Страница 13: ...do so could result in damage to equipment plugged into the unit and possi ble injury to the individual All engines have a tendency to slow down when a load is applied When the electrical load is connected to the generator the engine is more heavily loaded and as a result the speed drops slightly This slight decrease in speed together with the voltage drop within the generator itself results in a s...

Страница 14: ...erator at these sites a secondary emergency distribution panel may have to be installed The emergency distribution panel must be installed by a licensed electrician according to all CONNECTING THE LOADS APPLYING THE LOADS Allow the engine to warm up for two or three minutes before applying any load This will allow the engine to reach normal operating temperature and oil to circulate throughout the...

Страница 15: ...load on the generator during the initial start up See the nameplate on your generator for the amperage capabilities of your unit CAUTION EQUIPMENT DAMAGE Failure to properly limit and balance the load applied to the generator will cause the generator to produce low voltage and may damage the engine generator set It may also cause severe damage to the loads con nected to the generator at that time ...

Страница 16: ...ecommendation section in this manual NOTE This engine requires 38 4 ounces 1 2 qt of oil if completely drained Use caution when refilling the engine as some residual oil may have remained in the engine Always use the dipstick when filling the engine with oil to prevent overfilling E Replace filler plug F Start engine up and warm it up G After warming up the engine recheck the oil level and refill ...

Страница 17: ... every 300 hours of operation Always replace with the same spark plug that came in the engine and check gap before installing Spark plug gap is 0 030 Poor spark will also occur if spark plug wire does not fit firmly on spark plug If this happens reform the terminal to fit firmly on spark plug tip CARBON CANISTER Designed to collect store and dispose of fuel vapors created in the fuel tank fuel sys...

Страница 18: ...roperly should it be needed in an emergency GENERATOR MAINTENANCE Any major generator service including the installation or replacement of parts should be performed only by a qualified electrical service technician USE ONLY FACTORY APPROVED REPAIR PARTS A Bearing The bearing used in these generators is a heavy duty double sealed ball bearing They require no maintenance or lubrication B Receptacles...

Страница 19: ...19 60706 238 H GND GND G ND GND GND GND G3 G3 N N N N N N N G3 G1 G1 G1 G1 G1 G1 G1 G1 G1 G3 RECEPTACLE WIRING DIAGRAM ...

Страница 20: ...sole remedy for a failure under this warranty shall be limited to the repair of the product At WINCO s option material found to be defective in material or workmanship under normal use and service will be repaired or replaced For warranty service return the product within the warranty period to your nearest WINCO Authorized Service Center or to WINCO in Le Center Minnesota Duration Consumer Commer...

Отзывы: