WIN Enterprises PL-80930 Скачать руководство пользователя страница 1

       

Networking Appliance 

             

User’s Manual

Version

1.0

1U Rack-Mount Intel® Haswell-EP Xeon E5-2600V3 Series Processor and Intel®

C612 PCH Network System, support DDR4 up to 256GB, 4 PCIe x8 slot for

expansion NIC module, 2 x 2.5” or 1 x 2.5” & 1 x 3.5” SATA HDD, 2 USB, 2 GbE, 1

Console, CF, SATA DOM, 1 PCIe x8 slot, Redundant PSU

       

PL-80930

Custom x86 Embedded Solutions

WIN Enterprises, Inc. • 300 Willow Street, North Andover MA • Email: [email protected] • PH: 978-688-2000  

Содержание PL-80930

Страница 1: ...612 PCH Network System support DDR4 up to 256GB 4 PCIe x8 slot for expansion NIC module 2 x 2 5 or 1 x 2 5 1 x 3 5 SATA HDD 2 USB 2 GbE 1 Console CF SATA DOM 1 PCIe x8 slot Redundant PSU PL 80930 Cust...

Страница 2: ...Revision History Date Version Modification Editor 2015 12 24 1 0 First Release Jason Fan...

Страница 3: ...of International Business Machine Corporation Award is a trademark of Award Software International Inc Intel is a trademark of Intel RTL is a trademark of Realtek VIA is a trademark of VIA Technologie...

Страница 4: ...ion module with four GbE copper supports two pairs Gen 3 bypass 3 3 IP 384A Expansion module with eight GbE fiber 3 4 IP 385A Expansion module with eight GbE copper supports two pairs Gen 3 bypass 3 5...

Страница 5: ...Chapter 5 Utility Driver Installation 5 1 Operating System Support 5 2 System Driver Installation 5 3 LAN Driver Installation Appendix Appendix A Linux DOS Sample code Appendix B Cable Development Kit...

Страница 6: ...t up to 8 NIC modules and support multiple Ethernet module bays for flexible port configuration such as 10 Gigabit SFP Gigabit copper with BYPASS function or not and Gigabit fiber ports Maximum capabl...

Страница 7: ...ion module with 8 RJ45 GbE ports with two pairs Gen 3 bypass Intel I350 AM4 IP 386A Expansion module with 4 SFP 10 GbE ports Intel XL710 BM1 w o re driver IP 387A Expansion module with 2 QSFP 40 GbE p...

Страница 8: ...ttons LED 4x GPO LEDs via R 380A GP57 Yellow GP54 Yellow GP55 R ed GP56 Green Dimensions W x D x H 440mm W x 570mm D x 44mm H 17 2 W x 22 44 D x 1 73 H Operating Temperature Operating 0 40 C 32 104 F...

Страница 9: ...s Intel X540 BT2 IP 408B Expansion module with 2 RJ45 10G ports Intel X540 BT2 DK002 Cable development kit CB CO5204 00 Cross over 2M CB DB9200 01 Null modem cable 2M CB EC5200 00 Ethernet cat 5 cable...

Страница 10: ...near future After you unpack the goods inspect and make sure the packaging is intact Do not plug the power adapter to the appliance if you find it appears damaged Note Keep the PL 80930 in the origina...

Страница 11: ...eappliance Do not remove the anti static packing until you are ready to install the PL 80930 appliance Ground yourself before removing any system component from its protective anti static packaging To...

Страница 12: ...1 6 System Layout Front panel features Rear panel features...

Страница 13: ...1 7 Dimensions...

Страница 14: ...1 Connector Pin Define and Jumper Setting Connector List Connector Define CN1 VR12_I2C PIN HEADER CN2 USB PIN HEADER CN3 VGA BOX HEADER CN4 ATX_SWITCH CN5 CPLD JTAG CN6 DEBUG GPIO CN7 ATX I2C Connecto...

Страница 15: ...A3 2 CN22 SATA3 1 CN23 SATA3 3 CN24 USB3 0 PIN HEADER CN25 SATA3 4 CN26 PCIE X8 SLOT CN27 PCIE X8 SLOT CN28 PCIE X8 SLOT CN29 PCIE X8 SLOT CN30 PCIE X8 SLOT CN31 I O Connector CN33 SATA DOM PWR CN34 V...

Страница 16: ...SYSTEM FAN 2 1U FAN9_4 SYSTEM FAN 2 1U FAN10_5 SYSTEM FAN 2 1U CN1 VR12_I2C PIN Description 1 GND 2 DATA 3 CLK CN2 CN48 USB2 0 PIN HEADER PIN Description PIN Description 1 5V 2 5V 3 USB_CON_PN2 4 USB_...

Страница 17: ...on PIN Description 1 CPLD_TCK 2 GND 3 CPLD_TDO 4 3 3V_AUX 5 CPLD_TMS 6 NC 7 NC 8 NC 9 CPLD_TDI 10 GND CN6 DEBUG GPIO PIN Description 1 GPIO57 2 GND CN10 ATX I2C Connector PIN Description 1 CLK 2 DAT 3...

Страница 18: ...DER PIN Description PIN Description 1 3 3V 2 LPC_AD0 3 LPC_AD1 4 LPC_AD2 5 LPC_AD3 6 FRAME_N 7 RST_LPC 8 5V 9 CLK_33MHZ 10 PME_N 11 GND 12 NC 13 SERIRQ 14 LDRQ1 CN17 KEY PAD PIN HEADER PIN Description...

Страница 19: ...DAT 4 L_MDAT 5 NC 6 NC 7 GND 8 GND 9 5V 10 5V CN23 PCIE 12V_ATX4PIN RESERVED PIN Description PIN Description 1 GND 3 12V 2 GND 4 12V CN24 GPO PIN HEADER PIN Description PIN Description 1 SIO_GP70 2 3...

Страница 20: ...PD0 9 PD3 10 PD2 11 PD5 12 PD4 13 PD7 14 PD6 15 BK_CTRLN 16 BK_CTRLP CN28 ATX 24PIN PIN Description PIN Description 1 3 3V 13 3 3V 2 3 3V 14 12V 3 GND 15 GND 4 5V 16 PS_ON 5 GND 17 GND 6 5V 18 GND 7...

Страница 21: ...3_TX1_P 5 USB3_TX0_N 15 USB3_TX1_N 6 USB3_TX0_P 16 GND 7 GND 17 USB3_RX1_P 8 USB2_PN0 18 USB3_RX1_N 9 USB2_PP0 19 5V 10 NC 20 NC CN35 CN36 CN37 CN38 CN40 PCIE X8 SLOT CN45 I O Connector PIN Descriptio...

Страница 22: ...LAN2_CON_1N 27 SIO_GP55 28 LAN2_CON_2P 29 SIO_GP56 30 LAN2_CON_2N 31 SIO_GP57 32 LAN2_CON_3P 33 HDD_LED_N 34 LAN2_CON_3N 35 RIA_N2 36 3 3V_AUX 37 DTR_N2 38 P80_CTRL 39 GND 40 RESET_BTN _NMI CN47 SATA...

Страница 23: ...JP2 ATX AT SELECT 1 2 ATX DEFAULT 2 3 AT JP3 H W OR S W RESET 1 2 H W RESET DEFAULT 2 2 S W RESET JP4 CLEAR CMOS 1 2 Normal DEFAULT 2 3 Clear CMOS JP6 BYPASS LED OR GPIO LED 1 2 GPIO54 DEFAULT 2 3 ALL...

Страница 24: ...ter 3 Optional LAN Module Add on Card Settings 3 1 IP 384A Expansion module with 8 SFP GbE ports Intel 82580EB 3 2 IP 385A Expansion module with 8 RJ45 GbE ports with two pairs Gen 3 bypass Intel 8258...

Страница 25: ...3 3 IP 386A Expansion module with 4 SFP 10 GbE ports Intel XL710 B M1 w o re driver 3 4 IP 387A Expansion module with 2 Q SFP 40 GbE ports Intel XL710 B M2 w o re driver...

Страница 26: ...3 5 IP 405A Expansion module with 4 SFP GbE ports Intel i350 AM4 3 6 IP 406A Expansion module with 4 RJ45 GbE ports with two pairs Gen 3 bypass Intel i350 A M4...

Страница 27: ...th 4 RJ45 10G ports Intel X540 BT 2 3 8 IP 408B Expansion module with 2 RJ45 10G ports Intel X540 BT2 3 9 IP 380A Front I O module IP 380A is a front I O module with GPO LEDs two USB 2 0 port one RJ45...

Страница 28: ...or Date and time Memory capacity of the appliance Type of display adapter installed Number and type of disk drives The CMOS memory is maintained by battery installed on the PL 80930 board By using the...

Страница 29: ...t for a long time Find the original setup missing Replace the battery Change to a different type of CPU Run the AMI Flash program to update the system BIOS Run the BIOS setup program after you turn on...

Страница 30: ...anges and reboot the system Press F3 Optimized Defaults to load the Optimal default configuration values of the menu Pressing ESC anywhere in the program returns you to the main menu 4 3 Menu Options...

Страница 31: ...ollows 1 Choose Advanced from the main menu The following screen appears 2 Use the arrow keys to move between fields Modify the selected field using the PgUP PgDN keys Some fields let you enter numeri...

Страница 32: ...4 4 1 Platform Function SOL Switch Switch Console for COM2 or SOL Watch dog Mode Watch dog Mode Sec Min Watch dog Timer Watch dog Mode Sec Min...

Страница 33: ...4 4 2 LAN Bypass Function...

Страница 34: ...4 4 3 NCT6791D Super IO Configuration...

Страница 35: ...Serial Port 1 Configuration Set Parameters of Serial Port 1 Serial Port 2 Configuration Set Parameters of Serial Port 2 Serial Port Enables or Disables Serial Port Change Setting Device Settings...

Страница 36: ...4 4 4 System Hardware Monitor...

Страница 37: ...rial Port Console Redirection Legacy Serial Redirection Port Select a COM port to display redirection of Legacy OS and Legacy OPROM Messages COM0 COM1 Console Redirection Console Redirection Enable or...

Страница 38: ...Data Bits Data Bits Parity A parity bit can be sent with the data bits to detect some transmission errors Even parity bit is 0 if the num of 1 s in the data bits is even Odd parity bit is 0 if num of...

Страница 39: ...r ANSI VT100 terminals Recorder Mode With this mode enabled only text will be sent This is to capture Terminal data Resolution 100x31 Enables or disables extended terminal resolution Legacy OS Redirec...

Страница 40: ...bles or Disables 64bit capable Devices to be Decoded in Above 4G Address Space Only if System Supports 64 bit PCI Decoding SR IOV Support If system has SR IOV capable PCIe Devices this option Enables...

Страница 41: ...um Payload of PCI Express Device or allow System BIOS to select the value Extended Synch If ENABLED allows generation of Extended Synchronization patterns Lin k Training Retry Defines number of Retry...

Страница 42: ...mpletion Timeout In device Functions that support Completion Timeout programmability allows system software to modify the Completion Timeout value Default 50us to 50ms If Shorter is selected software...

Страница 43: ...refix Blocking If supported by hardware and set to Enabled this function will block forwarding of TLPs containing End End TLP Prefixes Clock Power Management If supported by hardware and set to Enable...

Страница 44: ...tive UPON REQUEST GA20 can be disabled using BIOS services ALWAYS do not allow disabling GA20 this option is useful when any RT code is executed above 1MB Option ROM Messages Set display mode for Opti...

Страница 45: ...4 4 8 USB Configuration...

Страница 46: ...for OSes without EHCI hand off support The EHCI ownership change should be claimed by EHCI driver USB Mass Storage Driver Support Enable Disable USB Mass Storage Driver Support USB transfer time out...

Страница 47: ...nd provides option to change the Common RefCode Settings QPI Configuration Displays and provides option to change the QPI Settings Memory Configuration Displays and provides option to change the Memor...

Страница 48: ...4 5 1 Processor Configuration Hyper threading Enabled for Windows XP and Linux OS optimized for Hyper Threading Technology...

Страница 49: ...3 VMX Enables the Vanderpool Technology takes effect after reboot Hardware Prefetcher Enable the Mid Level Cache L2 streamer prefetcher Adjacent Cache Prefetc h MLC Spatial Prefetcher DCU Streamer Pr...

Страница 50: ...4 5 1 1 CPU Core Configuration...

Страница 51: ...d Cores available In STR_CORE_ENABLE_HELP d will be replaced with number of cores IOT Cfg Cbo Bitmap Each bit enables IOT OCLA for a CBo 4 5 2 Advanced Power Management Configuration Power Technology...

Страница 52: ...PU frequency according load When disabled CPU frequency is set at max non turbo Turbo Mode Turbo mode allows a CPU logical processor to execute a higher frequency when enough power is available not ex...

Страница 53: ...ot P a ckage C State limit Package C State limit CPU C3 report Enable Disable CPU C3 ACPI C2 report to OS Recommended to be disabled CPU C6 report Enable Disable CPU C6 ACPI C2 report to OS Recommende...

Страница 54: ...4 5 2 3 CPU Advanced PM Tuning 4 5 2 3 1 Energy Perf BIAS Energy Performance BI Set Energy Performance BIAS which overrides OS setting...

Страница 55: ...of the average for C0 and P0 time P0 TotalTimeThreshold Low The HW switching mechanism DISABLES the performance setting 0 when the total P0 time is less than this threshhold P0 TotalTimeThreshold High...

Страница 56: ...ble or Enable Meseg Mode Numa Enable or Disable Non uniform Memory Access NUMA 4 5 4 QPI Configuration QPI General Configuration Displays and provides option to change the QPI General Settings CPU QPI...

Страница 57: ...ology if system options are in conflict Link Frequency Select Allows for selecting the QPI Link Frequency Link L0p Enable Link L0p Enable Disable Enable Auto default Link L1 Enable Link L1 Enable Disa...

Страница 58: ...Enable disable Home Dir Snoop with IVT Style OSB QPI Debug Print Level QPI Debug Print Level Enable Disable 4 5 4 1 1 QPI Status...

Страница 59: ...4 5 4 2 CPU QPI Configuration CPU QPI QPI Per Socket Configuration...

Страница 60: ...cation Bus resources allocation ratio range 0 to 8 IO Resources Allocation IO resources allocation ratio range 0 to 8 MMIOL Resources Allocation MMIOL resources allocation ratio range 0 to 8 IIO Disab...

Страница 61: ...4 5 5 Memory Configuration...

Страница 62: ...ximum Memory Frequency Selections in Mhz Do not select Reserved MRC Promote Warnings Determines if MRC warnings are promoted to system level Promote Warnings If enabled RC warnings are promoted to err...

Страница 63: ...test loops during normal boot set to 0 to run memtest infinitely Dram Maintenance Test Dram Maintenance Test during normal boot Dram Maintenance Test Direction Dram Maintenance Test Direction UP or D...

Страница 64: ...d Memtest on Fast Boot Enable disable memory test during fast boot RMT on Cold Fast Boot Enable Disable Rank Margin Tool on Cold Fast Boot BDAT Enable Disables BDAT Data Scrambling Enables data scramb...

Страница 65: ...Enable Disable issuing read commands opportunistically during WMM Normal Operation Duration Set normal operation duration interval 0 65535 Number of Sparing Transactions Set number of sparing transac...

Страница 66: ...4 5 6 IIO Configuration...

Страница 67: ...on reads and writes for Vc0 traffic Gen3 Phase3 Loop Count Gen3 Phase3 Loop Count 1 4 16 256 Skip Halt On DMI Degradation Enable this option to avoid the system to be halted on DMI width link degradat...

Страница 68: ...4 5 6 1 IIO Configuration 4 5 6 1 1 Socket 0 PcieD00F0 Port 0 DMI...

Страница 69: ...option enables disables the ASPM L1 for the downstream devices PCI E Port L0s Exit Latency The length of time this port requires to complete transition from L0s to L0 PCI E Port L1 Exit Latency The le...

Страница 70: ...4 5 6 1 2 Socket 0 PcieD01F0 Port 1A...

Страница 71: ...on enables disables the ASPM L1 for the downstream devices PCI E Port L0s Exit Latency The length of time this port requires to complete transition from L0s to L0 PCI E Port L1 Exit Latency The length...

Страница 72: ...tream Tx Preset Gen3 DN Rx Preset Hint PCIe Gen3 Downstream Rx Preset Hint Gen3 UP Tx Preset PCIe Gen3 Upstream Tx Preset Hide Port User can force to hide this root port from OS 4 5 6 1 3 Socket 0 Pci...

Страница 73: ...ational speed by restricting the values advertised by the Upstream component in its training sequences When Auto is selected HW initialized data will be used Override Max Link Wid Override the max lin...

Страница 74: ...error propogation to the IIO core error logic for this port L0s Support When disabled IIO never puts its transmitter in L0s state PM ACPI Mode When Disabled MSI is generated on PM event When Enabled _...

Страница 75: ...4 5 6 1 4 Socket 0 PcieD02F2 Port 2C...

Страница 76: ...ion enables disables the ASPM L1 for the downstream devices PCI E Port L0s Exit Latency The length of time this port requires to complete transition from L0s to L0 PCI E Port L1 Exit Latency The lengt...

Страница 77: ...et PCIe Gen3 Downstream Tx Preset Gen3 DN Rx Preset Hint PCIe Gen3 Downstream Rx Preset Hint Gen3 UP Tx Preset PCIe Gen3 Upstream Tx Preset Hide Port User can force to hide this root port from OS 4 5...

Страница 78: ...tional speed by restricting the values advertised by the Upstream component in its training sequences When Auto is selected HW initialized data will be used Override Max Link Wid Override the max link...

Страница 79: ...lization Mode Gen3 Spec Mode PCIe Gen3 Spec Mode Gen3 Phase2 Mode Gen3 Phase2 Mode Gen3 DN Tx Preset PCIe Gen3 Downstream Tx Preset Gen3 DN Rx Preset Hint PCIe Gen3 Downstream Rx Preset Hint Gen3 UP T...

Страница 80: ...2 or 39 disables BAR Secondary BAR 4 Size Used to set the prefetchable BAR 4 size on Secondary side of NTB Value than 12 or 29 39 for BIOS supporting 4G PCI disables BAR Secondary BAR 5 Size Used to s...

Страница 81: ...ational speed by restricting the values advertised by the Upstream component in its training sequences When Auto is selected HW initialized data will be used Override Max Link Wid Override the max lin...

Страница 82: ...to the IIO core error logic for this port L0s Support When disabled IIO never puts its transmitter in L0s state PM ACPI Mode When Disabled MSI is generated on PM event When Enabled _HPGPE message is...

Страница 83: ...4 5 6 2 IIO General Configuration IIO IOAPIC Enable Disable the IIO IOAPIC...

Страница 84: ...gnment to VMM through DMAR ACPI Tables ACS Control Enable Programs ACS only to Chipset Pcie Root Ports Bridges Disable Programs ACS to all Pcie bridges Interrupt Remapping Enable Disable VT_D Interrup...

Страница 85: ...4 5 7 PCH Configuration 4 5 7 1 PCH Devices...

Страница 86: ...r a G3 4 5 7 2 PCI Express Configuration PCI E ASPM Support This option enables disables the ASPM support for all downstream devices PCIE Clock Gating PCIE Clock Gating Enable Disable for all PCH PCIE...

Страница 87: ...1 Substates settings PME SCI PCI Express PME SCI Enable Disable Hot Plug Designates this port as Hot Pluggable PCIe Speed Configure PCIe Speed PME Interrupt PCI Express PME Interrupt Enable Disable Ex...

Страница 88: ...trol the PCI Express Root Port PCH PCIE ASPM PCI Express Root port ASPM Setting L1 Substates PCI Express L1 Substates settings PME SCI PCI Express PME SCI Enable Disable Hot Plug Designates this port...

Страница 89: ...ry Reserved Memory and Prefetchable Memory 1 20MB Range for this Root Bridge Reserved I O Reserved I O 4K 8K 12K 16K 20K Range for this Root Bridge 4 5 7 2 3 PCI Express Root Port 3 PCI Express Root P...

Страница 90: ...ed 0 7 for bridges behind this Root Bridge Reserved Memory Reserved Memory and Prefetchable Memory 1 20MB Range for this Root Bridge Prefetchable Memory Reserved Memory and Prefetchable Memory 1 20MB...

Страница 91: ...PME Interrupt PCI Express PME Interrupt Enable Disable MSI PCIE MSI Enable Disable Extra Bus Reserved Extra Bus Reserved 0 7 for bridges behind this Root Bridge Reserved Memory Reserved Memory and Pr...

Страница 92: ...ting L1 Substates PCI Express L1 Substates settings PME SCI PCI Express PME SCI Enable Disable Hot Plug Designates this port as Hot Pluggable PCIe Speed Configure PCIe Speed PME Interrupt PCI Express...

Страница 93: ...Root Bridge Reserved I O Reserved I O 4K 8K 12K 16K 20K Range for this Root Bridge 4 5 7 2 6 PCI Express Root Port 6 PCI Express Root Port Control the PCI Express Root Port PCH PCIE ASPM PCI Express...

Страница 94: ...ory Reserved Memory and Prefetchable Memory 1 20MB Range for this Root Bridge Prefetchable Memory Reserved Memory and Prefetchable Memory 1 20MB Range for this Root Bridge Reserved I O Reserved I O 4K...

Страница 95: ...Interrupt Enable Disable MSI PCIE MSI Enable Disable Extra Bus Reserved Extra Bus Reserved 0 7 for bridges behind this Root Bridge Reserved Memory Reserved Memory and Prefetchable Memory 1 20MB Range...

Страница 96: ...Substates PCI Express L1 Substates settings PME SCI PCI Express PME SCI Enable Disable Hot Plug Designates this port as Hot Pluggable PCIe Speed Configure PCIe Speed PME Interrupt PCI Express PME Inte...

Страница 97: ...mory 1 20MB Range for this Root Bridge Prefetchable Memory Reserved Memory and Prefetchable Memory 1 20MB Range for this Root Bridge Reserved I O Reserved I O 4K 8K 12K 16K 20K Range for this Root Bri...

Страница 98: ...es Link Power Management Port 0 1 2 Enable or Disable SATA Port Spin Up Device If enabled for any of ports Staggered Spin Up will be performed and only the drives which have this option enabled will s...

Страница 99: ...4 5 7 3 1 SATA Mode Options SATA Led locate If enabled LED SGPIO hardware is attached...

Страница 100: ...4 5 7 4 PCH SATA Configuration...

Страница 101: ...Link Power Management SATA Port 0 1 2 3 4 5 SATA Port 0 1 2 3 4 5 Software Preserve Software Preserve Port 0 1 2 3 4 5 Enable or Disable SATA Port Configure as eSATA Configures port as External SATA e...

Страница 102: ...entify the SATA port is connected to Solid State Drive or Hard Disk Drive 4 5 7 4 1 SATA Mode Options SATA HDD Unlock Enable HDD password unlock is enabled in the OS SATA Led locate If enabled LED SGP...

Страница 103: ...TCG USB Ports Per Port Control each of the USB ports 0 13 disabling XHCI Idle L1 Enabled XHCI Idle L1 Disabled to workaround USB3 hot plug will fail after 1 hot plug removal Please put the system to G...

Страница 104: ...Enable Disable the PCH GPIO Lockdown feature RTC Lock Enable will lock bytes 38h 3Fh in the lower upper 128 byte bank of RTC RAM BIOS Lock Enable Disable the PCH BIOS Lock Enable feature Host Flash L...

Страница 105: ...y Bus Number Specify the PCI minimum secondary bus number in system PCIe Extended Tag Enable Enable or Disable Extended Tag Enable Field Support PCIe AtomicOp Request Enable or disable AtomicOp Reques...

Страница 106: ...4 6 Server Mgmt...

Страница 107: ...BMC Wait For BMC response for specified time out In PILOTII BMC starts at the same time when BIOS starts during AC power ON It takes around 30 seconds to initialize Host to BMC interfaces BMC Warm Re...

Страница 108: ...press the F1 key for information on the various options 3 After you have finished with the Security setup press the or key to switch to other setup menu or press F4 key to save setting Administrator...

Страница 109: ...is set to Disabled the BIOS displays normal POST messages If Enabled an OEM Logo is shown instead of POST messages CDROM DVD Drive BBS Priorities Specifies the Boot Device Priority sequence from avai...

Страница 110: ...n menu the following screen appears 2 Move between items and select values by using the arrow keys Modify the selected fields using the PgUP PgDN keys For information on the various options please pre...

Страница 111: ...ease install the GbE modules properly before you install the OS driver or other software 5 1 Operation System Supporting PL 80930 can support Windows and Linux operating systems as follows Before inst...

Страница 112: ...ase click the Autorun file and install the driver following the procedures 1 Insert the setup CD of PL 80930into your CD ROM drive 2 Choose the Drivers file to click the Autorun icon 3 Follow the proc...

Страница 113: ...able 2M RoHS CB EC5200 00 1 Cross Over 2M Color RoHS CB CO5202 4 00 1 RJ45 to DB9 2M Cable RoHS CB RJDB91 00 1 2m null modem cable RoHS CB DB9200 01 1 VGA CABLE 2mm 15CM RoHS CB IVGA01 00 1 KB MS CABL...

Страница 114: ...parts and recycling This symbol of the crossed out wheeled bin indicates that the product electrical and electronic equipment should not be placed in municipal waste Check local regulations for the d...

Страница 115: ...ear adjustable brackets Loosen the nuts on the both brackets and decide the proper setback distance to the opening then tighten the nuts on the front brackets Step 3 Extend the rear brackets to where...

Страница 116: ...orward to secure the bracket It is important to check if the safety lock is in unlocked position before mounting the brackets Step 5 Attach the inner slide member to your chassis Attach the inner slid...

Страница 117: ...the chassis into the cabinet Pick up your chassis Insert your chassis with inner slide member into the intermediate member The chassis will be locked when it reaches the fully open position then pull...

Отзывы: