24 Wall tap control
WimTec OCEAN W6
EN
PROOF W6
Assembly
7
8
7.
Remove the sealing plug and mount the outlet pipe.
8
. Feed the power connection cable (2 x 0.5 mm
2
) and, if applicable, the control line for thermal
disinfection (2 x 0.5 mm
2
) into the flush-mount set and connect it/them to the power supply
(art. no. 117 899 , 113 792).
Attention: The power supply must not be installed in the flush-mount set!
9.
Connect the magnetic valve to the electronics module.
For models with thermal disinfection:
Connect the lower magnetic valve (red dot) to the
electronics module (cable with red marking).
10.
Connect the power cables to the electronics module (mind c/- polarity) and connect
the grounding wire (yellow) to the water path. Then turn on the power supply (safety lock
mechanism of the magnetic valve will be activate).
11.
Attach the mounting frame using the 4 screws supplied. Make sure that the cable connections
remain intact and the cables are not crimped. When tightening the screws, ensure that the
mounting frame does not get warped.
11
10
9