Wall tap control
WimTec OCEAN W6
19
EN
PROOF W6
Operating voltage:
via power supply 230 V 50 Hz / 12 V=
Art.No. 117 899 - power supply for one control unit
Art.No. 113 792 - power supply for up to 5 control units
Power consumption:
max. 3.5 W
Magnetic valve:
6 V cartrigde
Active range:
from 15 cm - 30 cm (30 cm factory setting)
Close-Active range:
4 - 5 cm
Flushing:
as long as user is in active range
Flushing stop:
from 10 s - 10 min (in manual program from 10 s - 60 s)
Stagnation rinse:
activatable, after 3 h - 48 h of none-use for 10 s
Continuous fl ow:
activatable, for 10 s - 10 min
Cleaning stopp:
activatable, for 3 min
Flow rate:
0,05 - 0,6 MPa (0,5 - 6 bar)
Static pressure:
max. 0,8 MPa (8 bar)
Water temperature:
max. 70 °C (max. 80 °C for max. 10 min)
Flow rate:
6 l/min (independent of pressure)
Water inlet:
R 1/2“ IT
Front plate:
Stainless-steel / Chromed brass
Thermost handle:
Chromed brass
Outlet:
Chromed brass
Specifi cations
Assembly
DN 15
Active range
15 - 30 cm
min 12 cm
Dimensions in mm
!
5°
20°
12 V=
Power supply:
2 x 0,5 mm
2
max. 100 m total cable length
Power supply one-fold Art.No. 117 899
Power supply fi ve-fold Art.No. 113 792
Power supply 230 V / 12 V not mountable in basic
kit or in any protective areas.
Control line for variant with TD:
2 x 0,5 mm
2
max. 100 m total cable length