Wall tap control
WimTec OCEAN W6
31
EN
PROOF W6
Program description
Stagnation rinse:
DIP switch 5
Serves to rinse water supply lines in order to remove stagnant water
that accumulates during longer periods of disuse.
DIP switch 5 ON = Stagnation rinse function enabled.
DIP switch 5 OFF = Stagnation rinse function disabled (default setting).
Time interval
Can be set from 3–48 h at
the interval control (see
p. 22).
Automatic stagnation rinse
If the fitting has not been
used for the set period, the
stagnation rinse operation is
automatically executed for
10 s.
Safety
If the cleaning stop function
is enabled, the stagnation
rinse function will only start
2 min after the cleaning stop
function has ended.
3–48 h
10 s
Werkseinstellung:
ON
OFF