background image

5. To save the new settings, press and hold the hot air iron function key until the display shows

“SAVE.” Press the up button (arrow up) of the hot air function to confirm saving.

In order to be able to work with the set values, please follow the next steps:

1. Make sure that the hot air function is switched off.
2. Hold down the hot air iron function button 

(17)

 until the display shows “run.”

3. Press the up button (arrow up) of the hot air function to start the automatic rework.

Once started, the station slowly begins to increase the temperature of the hot air unit. After the tem -
perature of segment A has been reached, it is counted down. When “0” is reached after the preset
time, the next segment is started until the entire program has run through. After the end of the pro -
gram, the cooling starts automatically.

Note:

The temperature of the hot air unit can be set from 100 

 to 480

 

.

The air flow rate is adjustable from 15 to 100 

min

.

The hot air unit is equipped with a temperature limiter which only allows a temperature in -
crease of 3 

s

. This corresponds to the industry standard and prevents sensitive components

from being damaged if the temperature rises too quickly.

Soldering iron

1. Insert the soldering iron into the 6-pin socket 

(9)

 provided on the front of the device.

2. Follow the instructions given under “Commissioning.”
3. If you want to use the fume extraction function, insert the hose of the fume extraction into the

socket provided for it 

(7).

4. Activate the on/off switch of the soldering iron 

(14).

 The soldering iron now heats up by itself to

350 

 (basic setting).

5. Set the required temperature using the temperature controller 

(4).

6. If you use the fume extraction system, press the on/off switch 

(15).

7. You can start working when the desired temperature is reached.
8. When you have completed the work, switch off the fume extraction system.
9. Switch off the soldering iron function.
10. Let the soldering iron cool down before packing it up.

© by WilTec Wildanger Technik GmbH 

Item 

Page 10

http://www.WilTec.de
http://www.aoyue.eu  

  

03 2021

-1

http://www.teichtip.de

Содержание 902703A+

Страница 1: ...he operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ in...

Страница 2: ...guages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our p...

Страница 3: ...damage do not use the device and immediately contact your dealer Switch off the device and pull the power plug if you want to move the device Avoid subjecting parts of the device to increased mechanic...

Страница 4: ...ea to avoid harmful concentrations Do not make any structural changes to the device Product description The Aoyue repairing hot air soldering station INT2703A combines the functions of a hot air gun a...

Страница 5: ...r iron soldering iron and desoldering gun Advanced air distribution technology air spreader Antistatic design ESD safe User friendly touchpad for easy and effective configuration Hot air and soldering...

Страница 6: ...ction Heat proof pad 30150J Desoldering iron with and holder Spring Desoldering tips Soldering iron holder and tin solder holder Cleaning tip Filter pads Electric cable End cap Vacuum suction pen 939...

Страница 7: ...operating elements Place the soldering iron on its holder as shown in the illustration Soldering fume extraction 1 Connect the soldering fume extractor hose to the socket provided for it 7 2 Make sure...

Страница 8: ...ir iron temperature automatic display 9 Desoldering gun connection 19 Hot air iron on off switch 10 Main switch Commissioning details Important Make sure that the device is on a level surface and that...

Страница 9: ...to 90 the display shows OFF 9 Switch off the system 10 Pull out the power plug When selecting the nozzle adapt it to the corresponding IC component Loosen the fastening screw of the hot air nozzle At...

Страница 10: ...hot air unit is equipped with a temperature limiter which only allows a temperature in crease of 3 s This corresponds to the industry standard and prevents sensitive components from being damaged if t...

Страница 11: ...ble Connecting to the station 1 Plug the connection cable of the desoldering gun into the socket 8 provided on the front of the device 2 Follow the instructions under Commissioning 3 Connect the vacuu...

Страница 12: ...next steps to switch off this safety function 1 Switch off the station and make sure that all function switches are set to off 2 Hold down the following two buttons hot air iron function switch 17 and...

Страница 13: ...ion The standby function of the desoldering iron is switched off at the factory To switch the function on please follow the next steps 1 Switch off the soldering function on the station 14 Make sure t...

Страница 14: ...on the station 14 make sure that the desoldering function is deactivated 12 6 Press and hold the up button of the desoldering function 4 7 Release the button when the temperature display of the solde...

Страница 15: ...conductivity is obtained when the tip is coated with fresh solder Replacing the soldering tip 1 Always switch off the soldering station before replacing the soldering tip 2 When the soldering tip is...

Страница 16: ...is recommended to rewet the pads regularly 2 Clean the filter spring and change the filters if they are contaminated 3 The solder line in the gun can be cleaned with the cleaning needle if necessary...

Страница 17: ...hich contains the filter pads the filter spring and the filter tube cover to be easily removed After removing the filter tube the filter pads and the filter spring can now be removed and cleaned or re...

Страница 18: ...nozzle 2 The inside of the nozzle and the surface are coated with a special alloy If this alloy is damaged by high temperat ures the nozzle can no longer heat up properly and evenly Replacing the hea...

Страница 19: ...ip cleaner 91806 makes this work easier for you 3 After use Always clean the soldering tip and re tin it before switching off This protects the soldering tip from oxidation and increases the service l...

Страница 20: ...use to ensure consistent performance 7 When finished work switch off the desoldering unit 8 Before putting the device away let the desoldering gun cool down Pressure display The pressure indicator he...

Страница 21: ...ance between the holder sides of the component holder to the width of the component to be desoldered 3 Melt the solder Hold the handle so that the nozzle is exactly above the component to be desoldere...

Страница 22: ...ump during transport and must be removed before using the station 6th problem The soldering iron temperature display shows PLUG Solutions a Check that the soldering iron has been inserted correctly b...

Страница 23: ...ts out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the corr...

Отзывы: