8. Faults, Causes and Remedies
A blockage of the pump can in most cases be
remedied by removing the suction connection and
scouring the pump backwards under pressure.
Switch-on pump several times for 2 secs during
scouring.
If the fault cannot be located or rectified, please
contact your nearest WILO representative.
Défauts
Causes
Remèdes
Pump does not run
Interruption of the current, short circuit,
Insulation fault in the motor coil
Check power supply, Call on expert to
check cable and motor
Pump is blocked due to foreign matters (1) – Switch off the pump voltage and secu-
re against reoperation.
– Close the shut-off fittings at the back
and front of the pump.
– Remove foreign bodies from the pump
Protective motor switch activated
(1 ~ -Motor)
Let the pump/motor cooling
Motor overheats
Too low voltage
Check voltage on terminals of the
motor.It should be within ± 6 % (50 Hz),
resp. ± 6 % (60 Hz) of the rated voltage
Pump is blocked due to foreign matters
(see 1)
Ambient temperature above +40 °C
The motor is aimed at operating at
a maximum ambient temperature
of +40 °C
Altitude > 1000 m
Motor is planned to operate at an altitu-
de ≤ 1000 m
Thermal relay
Value of the thermal relay (3 ~ -Motor) is
too low
Check the current with an ammeter or put
the value switches off of the cuttent rating
mentioned on the motor data plate
Voltage is too low
Check the adequate cross-section of the
electrical cable conductors
A phase is cut
Check it and change the electrical cable if
necessary
Thermal relay of the curcuit-breaker is
defective
replace it
Motor is defective
replace it
Pump runs, but no delivery or it
tranports too little
Pump is blocked due to foreign matters
(see 1)
Pump is empty
Fill the pump
Air in suction pipes
Check tightness of the whole pipe up to
the pump and make it tight
Suction pie obstructed
Clean all the pipes
Wrong rotating direction(3 ~ -Motor)
Cross two phase wires
Pump vibrates
Loose on ist foundation
Check and completely tighten the nuts
of the stud bolts
Pump is blocked due to foreign matters
(see 1)
Bad electrical connection
Check the connections to the pump
motor
Содержание Wilo-Jet-WJ
Страница 34: ...34 WILO AG 09 2009 20 30 4 3 5 2 30 VDE 0100 702 10 3 6 7 1 4 6...
Страница 35: ...35 WILO AG 09 2009 8 2 WILO 1 6 50 60 Hz 1 40 C 40 C 1000 1000 1 1...
Страница 38: ...38 WILO SE 09 2009 5 2 VDE 30 mA VDE 0100 702 10 A H07 RNF DIN 57282 DIN 57245 DM 3 6 DM 2 7 1 4 bar...
Страница 39: ...39 WILO SE 09 2009 8 2 WILO 1 1 6 50 Hz 6 60 Hz 1 40 C 40 C 1000 m 1000 m 3 1 3 2 1...
Страница 44: ...WILO SE 01 2009...
Страница 45: ......
Страница 46: ......