Wilo Wilo-HMHI Series Скачать руководство пользователя страница 9

English

22

WILO SE  11/2010

2.5

Safety instructions for inspection and 
installation work

The operator must ensure that all inspection and 
installation work is carried out by authorised and 
qualified personnel, who are sufficiently informed 
from their own detailed study of the operating 
instructions.
Work on the product/unit must only be carried out 
when at a standstill. It is mandatory that the pro-
cedure described in the installation and operating 
instructions for shutting down the product/unit 
be complied with.

2.6

Unauthorised modification and manufacture of 
spare parts

Modifications to the product are only permissible 
after consultation with the manufacturer. Original 
spare parts and accessories authorised by the 
manufacturer ensure safety. The use of other 
parts can nullify the liability from the results of 
their usage.

2.7

Improper use

The operating safety of the supplied product is 
only guaranteed for conventional use in accord-
ance with Section 4 of the operating instructions. 
The limit values must on no account fall under or 
exceed those specified in the catalogue/data 
sheet.

3 Transport and interim storage

When you receive the domestic water system, 
immediately check it for transport damage. If you 
discover transport damage, discuss with the cou-
rier company what measures to take, complying 
with the relevant notification deadlines!

CAUTION! Risk of damaging the domestic water 
system!
Danger of damage due to incorrect handling 
during transportation and storage.

The domestic water system must be protected 
against moisture, frost and mechanical damage 
when in transit. The domestic water system must 
never be exposed to temperatures beyond the 
range -10 °C to +50 °C during transport or stor-
age.

4 Application (intended use)

With its series of different domestic water sys-
tems, Wilo is offering water-supply units for 
domestic, DIY and garden applications. Depending 
on the pump used, the domestic water systems 
are suitable for:

• pumping water out of containers, ponds, streams 

and wells, for water supply, irrigation, sprinkling 
and spraying in the domestic context.
Non-self-priming or self-priming pumps are used, 
depending on the application. 

Non-self-priming pumps which can operate in 
inlet mode (e.g. from an open container) but are 
not self-priming, are allowed to be connected to 
the public water supply system directly (Fig. 2).

Self-priming pumps are equipped with air separa-
tion technology in the pump hydraulics, which 
enables them to evacuate air from a suction pipe 
(e.g. from a well) (Fig. 3). These are not allowed to 
be connected to the public water supply system, 
in order to avoid any negative effect on the mains 
pressure.

Permitted fluids:

• Water without any solid or sedimentary particles 

(process water, refrigerating water, cooling water 
and rainwater)
Use with other fluids or additives requires 
approval from Wilo

5 Product information

5.1 Type key

Example: HMC 304 EM

H

= Domestic water system with pump

MC

MP
WJ
MHI

Pump type
= Wilo-MultiCargo

= Wilo-MultiPress
= Wilo-Jet
= Wilo-Economy MHI

2

3

4
6

= Rated volume flow Q in m³/h 

02
03

04

05
06

= Number of hydraulic stages

EM
DM

= Alternating current 1 ~ 230 V
= Three-phase current 3 ~ 400 V

Содержание Wilo-HMHI Series

Страница 1: ...ing instructions F Notice de montage et de mise en service NL Inbouw en bedieningsvoorschriften Wilo Hauswasserwerke Hxx Wilo domestic water systems Hxx Stations de pompage domestiques Wilo Hxx Wilo h...

Страница 2: ...Fig 1 2 3 9 5 4 1 6 8 7 Fig 2 12 14 11 10 13 14 11...

Страница 3: ...Fig 3 14 10 12 14...

Страница 4: ...Fig 4a Fig 4b Fig 5a Fig 5b Fig 6a Fig 6b 1 2 3 4 5 1 4 2 3 5 1 4 2 3 5 1 2 3 4 5 pa bar pe bar pa bar pe bar...

Страница 5: ...Fig 7a Fig 7b Fig 7c Fig 8...

Страница 6: ...nd manufacture of spare parts 22 2 7 Improper use 22 3 Transport and interim storage 22 4 Application intended use 22 5 Product information 22 5 1 Type key 22 5 2 Technical data 23 5 3 Scope of delive...

Страница 7: ...usting screw for pressure difference switch off pressure switch on pressure 3 Supply line connections motor 4 Supply line connections system 5 Connections earthing PE Fig 5a and 5b Pressure switch DM...

Страница 8: ...om electrical voltage NOTE Signal words DANGER Acutely dangerous situation Non observance results in death or the most serious of injuries WARNING The user can suffer serious injuries Warning implies...

Страница 9: ...ortation and storage The domestic water system must be protected against moisture frost and mechanical damage when in transit The domestic water system must never be exposed to temperatures beyond the...

Страница 10: ...f the product The domestic water system is equipped with an electrically driven centrifugal pump a pressure switch and a diaphragm pressure vessel The diaphragm pressure vessel is divided into a water...

Страница 11: ...eter of the inlet pipe is not allowed to be less than the diameter of the pump s suction connection To avoid stresses being communicated by the weight of the piping the piping must be secured tothestr...

Страница 12: ...he domestic water system to operate correctly it is necessary to have a gas supply pres sure in the diaphragm pressure vessel that is appropriate for the switch on pressure In the fac tory setting the...

Страница 13: ...head HA 7 m Open check valve on the pressure side Fig 3 no 12 Remove filler screw Fig 1 no 2 Using a funnel slowly and completely fill the pump at the filler opening until water emerges from the open...

Страница 14: ...with the system parameters Switch off pressure agrees with the system parameters Check gas supply pressure of the diaphragm vessel see Table1 approx pE 0 2 0 5 bar or pE 10 Gas supply pressure of the...

Страница 15: ...can be heard Shut off electrical power supply and secure it to prevent it from being switched back on without authorisation Slowly open check valve on the pressure side and observe pressure gauge Tur...

Страница 16: ...ere is a risk of frost the system must be completely drained including the diaphragm pressure vessel The drainage screw Fig 1 no 3 is located on the underside of the pump Prior to a long standstill e...

Страница 17: ...aring damaged Clean pump Clean pump Have the pump repaired by Wilo cus tomer service Ambient temperature too high Improve the cooling and perform a restart after cooling down Geodesic head 1000 m Pump...

Страница 18: ...ctive 2006 95 EC are realized according annex I No 1 5 1 of the EC Machinery directive 2006 42 EC Les objectifs protection de la directive basse tension 2006 95 CE sont respect es conform ment appendi...

Страница 19: ...niejszym deklarujemy z pe n odpowiedzialno ci e dostarczony wyr b jest zgodny z nast puj cymi dokumentami Sm rnice ES pro strojn za zen 2006 42 ES dyrektyw maszynow WE 2006 42 WE EC 2006 42 EG C le t...

Страница 20: ...Mather and Platt Pumps Ltd Pune 411019 T 91 20 27442100 service pun matherplatt co in Indonesia WILO Pumps Indonesia Jakarta Selatan 12140 T 62 21 7247676 citrawilo cbn net id Ireland WILO Engineering...

Страница 21: ...henstra e 100 44263 Dortmund T 0231 4102 7900 T 01805 W I L O K D 9 4 5 6 5 3 F 0231 4102 7126 kundendienst wilo com T glich 7 18 Uhr erreichbar 24 Stunden Technische Notfallunterst tzung Kundendienst...