Installation
Installation and operating instructions Wilo-Star-Z NOVA
9
Engl
ish
Turn the motor head or
remove it
3.
Release the union nut - unscrew it completely
if necessary.
4.
Turn the motor head so that the Wilo-Con-
nector points downwards.
5.
Tighten the union nut again.
Open the stop valve
6.
Turn slot (1) with a screwdriver so that it is
parallel to the direction of flow (only in the
case of the Star-Z NOVA A, and Star-Z
NOVA C versions).
7.
Fit the thermal insulation shell.
Connecting
8.
Connect the pipework.
Caution:
Do not damage the housing seal.
Replace damaged seals.
Caution:
If the position is wrong, water
can penetrate and destroy the pump.
1
Note:
To close, turn the slot so that it is
across the direction of flow.
Caution:
The plastic parts of the motor
may not be heat-insulated in order to protect
the pump from overheating.
Caution:
For the versions with stop and
non-return valves, these are already pre-
installed and sealed with a tightening torque of
15 Nm (hand-tight). Screwing with excessive
tightening torque destroys the valve screw con-
nection and the O ring.
When installing the valve, use a fixed spanner to
prevent twisting.
Содержание Star-Z NOVA A
Страница 2: ......
Страница 52: ... 50 WILO SE 10 2012 J X 1 57 53 55 57 61 53 58 51 55 56 ...
Страница 60: ... 58 WILO SE 10 2012 J X 5 2 X X X _ X X X Y X X X X _ 1 _ 2 _ 3 _ 4 PE N L ...
Страница 112: ...JX 110 WILO SE 10 2012 1 _ µ 117 µ 113 µ 115 µ 117 µ 121 µ 113 µ 118 µ 111 µ 115 µ 116 ...
Страница 120: ... 118 WILO SE 10 2012 5 2 _ _ _ _ _ X _ À Á À º Á Ã À Ë º º º 1 2 3 4 PE N L ...
Страница 121: ... Wilo Star Z NOVA 119 5 3 1 Ä 2 Ì Á Ê Á À Ê º Æ À Á Ã È º Ê Á Ê Á º À º À Ê Ê 5 J WILO Connector _ X ...