3 Transport and interim storage
Immediately check the product for any transit damage on
arrival. If damage is found, the necessary procedures involving
the forwarding agent must be taken within the specified period.
CAUTION! Risk of damage to property!
Incorrect transport and interim storage can cause damage to
the product.
• The switchgear must be protected against moisture and
mechanical damage caused by blows/impact.
• It must not be exposed to temperatures outside the range
–10°C to +40°C.
4 Intended use
Wall-mounted unit for the electrical connection of single-
phase and three-phase pumps with integrated thermal winding
contacts (WSK) for monitoring the winding temperature (full
motor protection). Automatic reactivation of pump after power
failure and automatic fault acknowledgement after cooling off
of the motor.
DANGER! Risk of fatal accident!
The switchgear is not protected against explosions and may
not be operated in the explosive area.
Always install the switchgear outside the explosive area.
Intended use of the pump/installation also includes following
these instructions.
Any other use is not regarded as intended use.