Installation and electrical connection

14

WILO SE 2019-10

CAUTION
Total damage due to moisture ingress

The ingress of moisture into the connection cable damages the cable and the pump!
Never immerse the ends of the connection cable in fluid. Seal them tightly during
storage.

Newly delivered pumps can be stored for one year. Contact customer service before
storing the device for more than one year.

When storing the pump, please note the following points:

ƒ

Place the pump upright (vertical) on a firm bearing surface. 

Secure the pump against

falling over and slipping!

ƒ

The max. storage temperature is -15 °C to +60 °C (5 °F to 140 °F). The max. relative
humidity is 90 %, non-condensing. We recommend frost-proof storage. Ambient
temperature: 5 to 25 °C (41 to 77 °F), relative humidity: 40 to 50 %.

ƒ

Do not store the pump in rooms in which welding work is carried out. The resulting
gases or radiation can corrode the elastomer parts and coatings.

ƒ

Seal the suction and pressure connection tightly.

ƒ

Protect the connection cable against kinking and damage. Maintain a constant bend
radius!

ƒ

Impellers must be turned by 180° at regular intervals (3 – 6 months). This prevents
the bearings from jamming and renews the lubrication film on the mechanical seal.

WARNING! There is a risk of injury due to sharp edges on the impeller and suction
port!

ƒ

Elastomer parts and the coating are subject to natural brittleness. Contact customer
service if the mixer has to be stored for more than 6 months.

After storage, remove any dust and oil from the pump and check the coating for dam-
age. Repair damaged coatings before further use.

6

Installation and electrical con-
nection

6.1

Personnel qualifications

ƒ

Electrical work: A qualified electrician must carry out the electrical work.

ƒ

Installation/dismantling: The technician must be trained in the use of the necessary
tools and fixation materials for the relevant construction site.

6.2

Installation types

ƒ

Vertical portable wet well installation

The following installation types are 

not

 permitted:

ƒ

Vertical stationary wet well installation with suspension unit

ƒ

Vertical stationary dry well installation

ƒ

Horizontal installation

6.3

Operator responsibilities

ƒ

Observe the locally applicable professional and trade association accident preven-
tion and safety regulations.

ƒ

Observe all regulations for working with heavy loads and under suspended loads.

ƒ

Provide protective equipment and ensure that the protective equipment is worn by
personnel.

ƒ

Observe local regulations on the latest technology for the disposal of wastewater
and sewage (without faeces).

ƒ

Avoid pressure surges!

ƒ

Check that the available consulting documents (installation plans, design of the op-
erating space, inflow conditions) are complete and correct.

6.4

Installation

DANGER
Risk of fatal injury due to dangerous lone working practices!

Work in chambers and narrow rooms as well as work involving risk of falling are dan-
gerous work. Such work may not be carried out autonomously! A second person
must be present for safety reasons.

Содержание Padus PRO

Страница 1: ...Pioneering for You Wilo Padus PRO 6084247 Ed 02 2019 10 en Installation and operating instructions...

Страница 2: ......

Страница 3: ...3 Operating modes 11 4 4 Operation with frequency converter 11 4 5 Operation in an explosive atmosphere 11 4 6 Technical data 11 4 7 Type key 12 4 8 Scope of delivery 12 5 Transportation and storage...

Страница 4: ...g fluid 23 9 4 Maintenance intervals 23 9 5 Maintenance measures 24 10 Repairs 26 10 1 Adjusting the impeller clearance 26 11 Faults causes and remedies 27 12 Spare parts 30 13 Disposal 30 13 1 Oils a...

Страница 5: ...law The defects are reported in writing to the manufacturer within the warranty period Application according to intended use All monitoring devices are connected and tested before commissioning Exclus...

Страница 6: ...ARNING Failure to follow the instructions can lead to serious injuries CAUTION Failure to follow the instructions can lead to property damage and a possible total loss NOTICE Useful information on han...

Страница 7: ...rical work must be carried out by a qualified electrician Before commencing work disconnect the product from the mains and secure it against being switched on again Observe applicable local regulation...

Страница 8: ...g if the operator s field of vision is blocked Persons must not stand underneath suspended loads Do not move suspended loads over workplaces where people are present 2 7 Installing dismantling Wear th...

Страница 9: ...ure of several bar can build up in the motor This pressure escapes when the screw plugs are opened If screw plugs are opened without due cau tion they can be ejected at high speed To avoid injuries ob...

Страница 10: ...received and read the work regulations The submersible pumps must not be used for pumping Drinking water Sewage with or without faeces Acids or alkaline solutions Fluids containing hard components suc...

Страница 11: ...ch The plug is designed for use in commercially available shock proof or CEE sockets and is not overflow proof 4 2 Monitoring devices The thermal motor monitoring protects the motor winding from overh...

Страница 12: ...multi channel impeller 08 Size L Hydraulics n a standard version L low pressure version T Mains connection version M 1 T 3 039 10 rated power P2 in kW 5 Mains connection frequency 5 50 Hz 6 60 Hz 40...

Страница 13: ...if unprotected and may be damaged Lift wet packaging carefully and replace it immediately Only remove the outer packaging at the place of utilisation to ensure that the pump is not damaged during tran...

Страница 14: ...rvice if the mixer has to be stored for more than 6 months After storage remove any dust and oil from the pump and check the coating for dam age Repair damaged coatings before further use 6 Installati...

Страница 15: ...n must have a firm surface Attach the lifting gear to the handle using a shackle Only use lifting gear which has been technically approved The laid connection cables must enable safe operation Check w...

Страница 16: ...ign the pump at the installation location 3 Place the pump on a solid load bearing surface CAUTION Prevent the pump sink ing in 4 Lay the pressure hose and fasten it to a certain point e g drainage DA...

Страница 17: ...he local regulations In case of sensitive mains make provision for the installation on site of other protective equipment e g overvoltage undervoltage or phase failure re lay etc Residual current devi...

Страница 18: ...verflow proof Observe the information on the protection class IP of the plug DANGER If the pump is to be connected directly to the switchgear arrange for the electrical connection to be carried out by...

Страница 19: ...direction of rotation If the direction of rotation is incorrect exchange the two phases at the mains connec tion Pumps with CEE plug and phase inverter AUTO RESET 180 ON OFF 1 2 Fig 6 Phase inverter 1...

Страница 20: ...e pump to cool down at ambient temperature after switching it off When operating the pump observe the locally applicable regulations on the following topics Workplace safety Accident prevention Handli...

Страница 21: ...dry run is not permitted Non compliance can result in irreparable damage 8 4 Removal DANGER Danger due to fluids hazardous to health If the pump is used in fluids hazardous to health decontaminate th...

Страница 22: ...quirement observe the spe cifications of the work regulations The operator must make sure that the personnel have received and read the work regulations Pump is dismantled Contaminated cleaning water...

Страница 23: ...icable guidelines Provide the tools required If flammable solvents and cleaning agents are used open flames naked lights and smoking are prohibited 9 3 Operating fluid 9 3 1 Oil types Medicinal white...

Страница 24: ...s Cracks Scratches Abrasion Pinch points If damage is identified on the connection cable decommission the pump immediately Have the connection cable replaced by Wilo customer service Only operate the...

Страница 25: ...mantled and cleaned decontaminated if required 1 Position the pump in a horizontal position on a firm surface The screw plug should face upwards WARNING Risk of hands being crushed Make sure that the...

Страница 26: ...be met prior to starting repair work Pump cooled down to the ambient temperature Pump is switched voltage free and secured against being activated inadvertently Pump cleaned thoroughly and disinfecte...

Страница 27: ...ction strainer with baseplate in place 14 Screw in the four hexagon nuts with washers and tighten Max tightening torque 20 Nm Impeller clearance corrected 11 Faults causes and remedies DANGER Danger d...

Страница 28: ...ing to the technical specifications by a qualified electrician and reset monitor ing equipment Check the impeller to make sure that it runs smoothly clean the hydraulics if necessary Fault Pump starts...

Страница 29: ...er clearance too great Adjust the impeller clearance 8 Pipe system on the pressure side or pressure hose clogged Remove clogging and replace the damaged components if necessary 9 Strongly gassing flui...

Страница 30: ...rotective clothing Used protective clothing must be disposed off in accordance with the locally applicable guidelines 13 3 Information on the collection of used electrical and electronic products Prop...

Страница 31: ...ilo it Kazakhstan WILO Central Asia 050002 Almaty T 7 727 312 40 10 info wilo kz Korea WILO Pumps Ltd 20 Gangseo Busan T 82 51 950 8000 wilo wilo co kr Latvia WILO Baltic SIA 1019 Riga T 371 6714 5229...

Страница 32: ...Pioneering for You WILO SE Nortkirchenstr 100 44263 Dortmund Germany T 49 0 231 4102 0 T 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: