Commissioning
en
Installation and operating instructions Wilo-Padus PRO
47
Checking the direction of rotation
A qualified electrician checks the rotating field at the mains connection with a rotating-
field testing device. To allow the correct direction of rotation, a clockwise rotating field
must be available at the mains connection. The pump is
not
approved for operation
with a counter-clockwise rotating field!
CAUTION! If the direction of rotation is
checked with a test run, comply with the environmental and operating conditions!
Incorrect direction of rotation
If the direction of rotation is incorrect, exchange the two phases at the mains connec-
tion.
Pumps with CEE plug and phase inverter
AUTO
RESET
180°
ON
OFF
1
2
Fig. 6:
Phase inverter
1. Insert CEE plug into the socket.
2. Check the control lamp.
⇒ Control lamp off: Direction of rotation correct.
⇒ Control lamp on: Incorrect direction of rotation.
3. Correct the direction of rotation.
⇒ Use a suitable screwdriver to push the phase inverter into the plug and turn by
180°.
▶ Direction of rotation set correctly.
7.4
Operation in an explosive atmo-
sphere
Operation in an explosive atmosphere is not permitted.
7.5
Before switching on
Check the following prior to activation:
▪ Check whether the device has been installed properly and in accordance with the locally
applicable regulations:
– Has the pump been earthed?
– Has the power supply cable routing been tested?
– Has the electrical connection been carried out in accordance with regulations?
– Are all mechanical components attached correctly?
▪ Check level control:
– Can the float switches move freely?
– Have the switching levels been tested (pump on, pump off, minimum water level)?
– Is additional dry-running protection installed?
▪ Check the operating conditions:
– Have the min./max. temperatures of the fluid been tested?
– Has the max. immersion depth been checked?
– Is the max. switching frequency complied with?
– Has a hard base been installed in the case of soft flooring?
– Are all gate valves open?
7.6
Switching on and off
During the start process, the rated current is temporarily exceeded. During operation,
the rated current may no longer be exceeded.
CAUTION! If the pump does not start,
switch off the pump immediately. Remove the fault before reactivating the pump!
Pumps with bare cable end
The pump must be switched on and off using a separate operating point (on/off switch,
switchgear) provided by the customer.
Pump with attached plug
▪ After inserting the plug into the socket, the pump is ready for operation. The pump is
switched on and off with the ON/OFF switch.
Содержание Padus PRO M08L/T039-540/A
Страница 2: ......
Страница 3: ...3 Deutsch 4 English 31 Fran ais 58 Svensk 86 Polski 112 Rom n 141 P 169...
Страница 170: ...ru 170 WILO SE 2019 03 9 190 9 1 191 9 2 191 9 3 191 9 4 191 9 5 192 10 194 11 197 12 197 12 1 197 12 2 197 12 3 197...
Страница 171: ...ru Wilo Padus PRO 171 1 1 1 1 2 1 3 1 4 www wilo com legal 2...
Страница 172: ...ru 172 WILO SE 2019 03 2 1 1...
Страница 173: ...ru Wilo Padus PRO 173 2 2 2 3...
Страница 174: ...ru 174 WILO SE 2019 03 2 4 RCD RCD RCD 2 5 2 6 2 7...
Страница 175: ...ru Wilo Padus PRO 175 2 8 40 C 104 F 85 A 85 A 2 9...
Страница 176: ...ru 176 WILO SE 2019 03 2 10 2 11 16 18 3 3 1 10 pH 4 8 3 2...
Страница 180: ...ru 180 WILO SE 2019 03 Fig 2 5 3...
Страница 181: ...ru Wilo Padus PRO 181 15 C 60 C 5 F 140 F 90 5 C 25 C 41 F 77 F 40 50 3 6 180 6 6 6 1 6 2 6 3...
Страница 182: ...ru 182 WILO SE 2019 03 6 4 IP 6 4 1 6 6 4 1 1...
Страница 183: ...ru Wilo Padus PRO 183 1 2 6 4 2 1 2 3 4 5 6 7 Fig 3 1 2 Storz 3 Storz 4 5 6 7 Storz 1 2 3 4 5...
Страница 184: ...ru 184 WILO SE 2019 03 6 4 3 6 5 6 5 1 RCD RCD RCD...
Страница 186: ...ru 186 WILO SE 2019 03 6 5 4 1 5 6 5 4 2 5 30 6 5 5 7 7 1 7 2 7 3...
Страница 188: ...ru 188 WILO SE 2019 03 10 2 5 1 8 8 1 8 2 8 3 3 C 37 F 1...
Страница 189: ...ru Wilo Padus PRO 189 2 5 8 4 8 4 1 1 2...
Страница 190: ...ru 190 WILO SE 2019 03 3 4 5 6 8 4 2 1 2 30 10 in 3 4 5 6 9...
Страница 192: ...ru 192 WILO SE 2019 03 9 4 1 4000 15000 9 4 2 9 5 9 5 1 9 5 2...
Страница 193: ...ru Wilo Padus PRO 193 9 5 3 9 5 4 9 5 4 1 0 9 5 5...
Страница 194: ...ru 194 WILO SE 2019 03 1 Fig 7 1 1 2 3 4 5 6 7 8 5 9 ft lb 8 9 8 5 9 ft lb 9 5 6 10...
Страница 195: ...ru Wilo Padus PRO 195 1 2 1 2 3 4...
Страница 196: ...ru 196 WILO SE 2019 03 5 6 7 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 11...
Страница 197: ...ru Wilo Padus PRO 197 1 2 3 4 5 6 7 8 11 12 12 1 12 2 12 3...
Страница 198: ...ru 198 WILO SE 2019 03 www wilo recycling com...