Installation and electrical connection
en
Installation and operating instructions Wilo-Padus PRO
45
▪ Earth the device properly in accordance with applicable local regulations.
6.5.1
Fuse on mains side
Circuit breaker
The size and switching characteristics of the circuit breakers must conform to the rated
current of the connected product. Observe local regulations.
Motor protection switch
Make provision for an on-site motor protection switch for devices without a plug! The
minimum requirement is a thermal relay/motor protection switch with temperature
compensation, differential triggering and anti-reactivation device in accordance with
the local regulations. In case of sensitive mains, make provision for the installation on-
site of other protective equipment (e.g. overvoltage, undervoltage or phase failure re-
lay, etc.).
Residual-current device (RCD)
Comply with the regulations of the local energy supply company! The use of a residual-
current device is recommended.
If persons come into contact with the device and conductive fluids, secure the connec-
tion
with
a residual-current device (RCD).
6.5.2
Maintenance tasks
Check the insulation resistance of the motor winding before installation. If the meas-
ured values differ from the specifications, moisture may have penetrated into the mo-
tor or the connection cable. Contact customer service in the event of a fault.
6.5.2.1
Checking the insulation resistance
of the motor winding
Use an insulation tester to measure the insulation resistance (measuring
voltage = 1000 V). Observe the following values:
▪ At the time of initial commissioning: Insulation resistance may not be less than 20 MΩ.
▪ For further measurements: Value must be greater than 2 MΩ.
NOTICE! For motors with an integrated capacitor, short-circuit the windings prior to
checking!
6.5.3
Three-phase current motor con-
nection
NOTICE! A clockwise rotating field must be available to allow the correct direction
of rotation.
NOTICE! The individual wires are identified according to the connection diagram. Do
not cut the wires! There is no further relationship between the wiring diagram and
the connection diagram.
Standard version without plug and float switch
bn
bk
M 3~
gn-y
e
W
V
gy
U
PE
Fig. 4:
Connection diagram for three-phase
current motor without plug and float switch
Wire colour
Designation
Terminal
Grey (gy)
U
L1
Black (bk)
V
L2
Brown (bn)
W
L3
Green/yellow (gn-ye)
Earth
PE
The connection cable features bare cable ends. Connection to the mains is established
by connecting the connection cable in the switchgear.
Electrical connection must al-
ways be carried out by a qualified electrician!
Содержание Padus PRO M08L/T039-540/A
Страница 2: ......
Страница 3: ...3 Deutsch 4 English 31 Fran ais 58 Svensk 86 Polski 112 Rom n 141 P 169...
Страница 170: ...ru 170 WILO SE 2019 03 9 190 9 1 191 9 2 191 9 3 191 9 4 191 9 5 192 10 194 11 197 12 197 12 1 197 12 2 197 12 3 197...
Страница 171: ...ru Wilo Padus PRO 171 1 1 1 1 2 1 3 1 4 www wilo com legal 2...
Страница 172: ...ru 172 WILO SE 2019 03 2 1 1...
Страница 173: ...ru Wilo Padus PRO 173 2 2 2 3...
Страница 174: ...ru 174 WILO SE 2019 03 2 4 RCD RCD RCD 2 5 2 6 2 7...
Страница 175: ...ru Wilo Padus PRO 175 2 8 40 C 104 F 85 A 85 A 2 9...
Страница 176: ...ru 176 WILO SE 2019 03 2 10 2 11 16 18 3 3 1 10 pH 4 8 3 2...
Страница 180: ...ru 180 WILO SE 2019 03 Fig 2 5 3...
Страница 181: ...ru Wilo Padus PRO 181 15 C 60 C 5 F 140 F 90 5 C 25 C 41 F 77 F 40 50 3 6 180 6 6 6 1 6 2 6 3...
Страница 182: ...ru 182 WILO SE 2019 03 6 4 IP 6 4 1 6 6 4 1 1...
Страница 183: ...ru Wilo Padus PRO 183 1 2 6 4 2 1 2 3 4 5 6 7 Fig 3 1 2 Storz 3 Storz 4 5 6 7 Storz 1 2 3 4 5...
Страница 184: ...ru 184 WILO SE 2019 03 6 4 3 6 5 6 5 1 RCD RCD RCD...
Страница 186: ...ru 186 WILO SE 2019 03 6 5 4 1 5 6 5 4 2 5 30 6 5 5 7 7 1 7 2 7 3...
Страница 188: ...ru 188 WILO SE 2019 03 10 2 5 1 8 8 1 8 2 8 3 3 C 37 F 1...
Страница 189: ...ru Wilo Padus PRO 189 2 5 8 4 8 4 1 1 2...
Страница 190: ...ru 190 WILO SE 2019 03 3 4 5 6 8 4 2 1 2 30 10 in 3 4 5 6 9...
Страница 192: ...ru 192 WILO SE 2019 03 9 4 1 4000 15000 9 4 2 9 5 9 5 1 9 5 2...
Страница 193: ...ru Wilo Padus PRO 193 9 5 3 9 5 4 9 5 4 1 0 9 5 5...
Страница 194: ...ru 194 WILO SE 2019 03 1 Fig 7 1 1 2 3 4 5 6 7 8 5 9 ft lb 8 9 8 5 9 ft lb 9 5 6 10...
Страница 195: ...ru Wilo Padus PRO 195 1 2 1 2 3 4...
Страница 196: ...ru 196 WILO SE 2019 03 5 6 7 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 11...
Страница 197: ...ru Wilo Padus PRO 197 1 2 3 4 5 6 7 8 11 12 12 1 12 2 12 3...
Страница 198: ...ru 198 WILO SE 2019 03 www wilo recycling com...