11
WILO SE 05/2013
English
1. General
These installation and operating instructions are
an integral part of the product. They must be
kept readily available at the place where the
product is installed. Strict adherence to these
instructions is a precondition for the proper use
and correct operation of the product.
These installation and operating instructions
conform to the relevant version of the product
and the underlying safety standards valid at the
time of going to press.
1.1 Applications
Pumps aimed at clear liquids in building, agricul-
ture and industry areas … (water supply – water
tower - sprinkling, irrigation, high pressure
washing , fire protection, – Lifting of conden-
sates – air conditioning – Industrial circuits and
integration in all modular systems.).
- boiler supply (with mandatory by-pass kit).
1.2 Technical characteristics
• Maximum operating pressure (Depending on
types):
• Temperature range:
(EPDM O’ring and mechanical seal) - 15° to + 90°C
• Ambient temperature (standard): + 40°C maxi
• Maximum suction head: according to NPSH of the
pump
Sound level
: Depends on pump size, rotation
speed, working point, motor type: it can exceed
70 dB(A) in 50 Hz and 75 dB(A) in 60 Hz.
2. Safety
These instructions contain important information
which must be followed when installing and
operating the pump. It is therefore imperative
that they be read by both the installer and the
operator before the pump is installed or operat-
ed. Both the general safety instructions in this
section and the more specific safety points in
the following sections should be observed.
2.1 Instruction symbols used in this operating
manual
Symbols
General danger symbol.
Hazards from electrical causes.
NOTE: ....
Signal words:
DANGER ! Imminently hazardous situation. Will
result in death or serious injury if not avoided.
WARNING ! Risk of (serious) injury. 'Warning'
implies that failure to comply with the safety
instructions is likely to result in (severe) per-
sonal injury.
CAUTION ! Risk of damage to the pump/instal-
lation. ‘Caution’ alerts to user to potential
product damage due to non-compliance with
the safety instructions.
NOTE ! Useful information on the handling of the
product.
It alerts the user to potential difficulties.
2.2 Personnel qualification
The personnel installing the pump must have the
appropriate qualification for this work.
2.3 Risks incurred by failure to comply with the
safety instructions
Failure to comply with the safety precautions
could result in personal injury or damage to the
pump or installation. Failure to comply with the
safety precautions could also invalidate any claim
for damages.
In particular, failure to comply with these safety
instructions could give rise, for example, to the
following risks:
• Failure of important pump or system functions,
• Failure of specified maintenance and repair
methods
• Personal injury due to electrical, mechanical and
bacteriological causes.
• Damage to property.
2.4 Safety instructions for the operator
The relevant accident precaution regulations
must be observed.
Potential dangers caused by electrical energy
must be excluded. Local or general regulations
[e.g. IEC, VDE, etc.] and directives from local
energy supply companies are to be followed.
2.5 Safety instructions for inspection and assem-
bly
The operator must ensure that all inspection and
assembly work is carried out by authorised and
qualified specialists who have carefully studied
these instructions.
Work on a pump or installation should only be
carried out once the latter has been brought to a
standstill.
2.6 Unauthorised modification and manufacture of
spare parts
Changes to the pump/machinery may only be
made in agreement with the manufacturer. The
use of original spare parts and accessories
authorised by the manufacturer will ensure safe-
ty. The use of any other parts may invalidate
claims invoking the liability of the manufacturer
for any consequences.
102 - 105
Mechanical seal 10 bars
302 - 304
Pump casing 16 bars
502 - 504
Maximum suction
802 - 804
pressure: 6 bars
106 - 112
Mechanical seal 16 bars
305 - 312
Pump casing 16 bars
505 - 512
Maximum suction
805 - 807
pressure: 10 bars
Содержание MVIL
Страница 2: ...8 Fig 1 Fig 2 Fig 4 B 4 13 H Fig 3 Fig 5...
Страница 4: ...WILO SE 05 2013...
Страница 57: ...57 WILO SE 05 2013 T 40 C 10 T 60 C 5 10 20 20 5 m 20 7 8 NPSH...
Страница 58: ...58 WILO SE 05 2013 Wilo 9 Wilo 10 50 Hz 6 60 Hz 40 C 40 C 4 2 Ha...
Страница 99: ...99 WILO SE 05 2013 20 7 8...
Страница 100: ...100 WILO SE 05 2013 Wilo 9 Wilo 10 50 6 60 40 C 40 C 4 3 2 Ha...
Страница 141: ...141 WILO SE 05 2013 20 7 NPSH 8...
Страница 142: ...142 WILO SE 05 2013 Wilo 9 Wilo 10 50 Hz 6 60 Hz 40 C 40 C 4 2 Ha...
Страница 144: ......
Страница 146: ......