background image

D

EG - Konformitätserklärung

GB 

EC – Declaration of conformity 

F

Déclaration de conformité CEE 

Hiermit erklären wir, dass die Bauarten der Baureihe : 

MVIE 1ph

Herewith, we declare that this product:

MHIE 1ph 

Par le présent, nous déclarons que cet agrégat : 

in der gelieferten Ausführung folgenden einschlägigen Bestimmungen entspricht: 

in its delivered state comply with the following relevant provisions: 
est conforme aux dispositions suivants dont il relève: 

EG-Maschinenrichtlinie 98/37/EG 
EC-Machinery directive 
Directives CEE relatives aux machines 

Elektromagnetische Verträglichkeit - Richtlinie 

2004/1008/EG 

Electromagnetic compatibility - directive 
Compatibilité électromagnétique- directive 

Niederspannungsrichtlinie 2006/95/EG 
Low voltage directive 
Direction basse-tension 

Angewendete harmonisierte Normen, insbesondere:

EN 809

Applied harmonized standards, in particular: 

EN 60204-1

Normes harmonisées, notamment: 

EN 61800-3

Bei einer mit uns nicht abgestimmten technischen Änderung der oben genannten Bauarten, verliert diese Erklärung ihre Gültigkeit. 
If the above mentioned series are technically modified without our approval, this declaration shall no longer be applicable. 
Si les gammes mentionnées ci-dessus sont modifiées sans notre approbation, cette déclaration perdra sa validité. 

Dortmund, 05.09.2008 

Erwin Prieß 

Quality Manager 

WILO SE 
Nortkirchenstraße 100 

44263 Dortmund 

Document: 2089935.2 

Содержание MHIE 1ph

Страница 1: ...operating instructions F Notice de montage et de mise en service NL Inbouw en bedieningsvoorschriften E Instrucciones de instalaci n y funcionamiento I Istruzioni di montaggio uso e manutenzione P Man...

Страница 2: ...Fig 1 Fig 3 Fig 2 Fig 4 Fig 5 or ou or ou...

Страница 3: ...Fig 6 Fig 8 Fig 7 or ou or ou...

Страница 4: ...Fig 9 Fig 10...

Страница 5: ...operating instructions 15 F Notice de montage et de mise en service 26 NL Inbouw en bedieningsvoorschriften 38 E Instrucciones de instalaci n y funcionamiento 50 I Istruzioni di montaggio uso e manut...

Страница 6: ...ticular the failure to observe these instruc tions could lead to the following hazards Failure of important functions of the pump instal lation Hazards to personnel resulting from electrical mechanica...

Страница 7: ...ssel Pos 9 or potable water network Pos 10 5 1 Installation Install the pump at a readily accessible location which is protected against external influences excessive rain or sunlight frost and which...

Страница 8: ...fications The electrical properties frequency voltage nominal current of the motor frequency convert er are indicated on the name plate of the motor of the pump A check is to be made as to whether the...

Страница 9: ...remove upper cover of the frequency converter Mains connection Connect three lines of the cable to the 3 connection terminals of the board Phase Neutral Earth Connecting the inputs outputs 3 operating...

Страница 10: ...3 cores 0 V 0 10 V 24 V 1 1 10 V 0 V 24 V 24 V 2 3 4 5 6 7 8 9 10 11 12 13 14 0 V 4 20 mA 24 V 0 V 0 10 V 24 V 2 Connection of the potentiometer Connection terminals Inputs outputs of the frequency co...

Страница 11: ...12 13 14 4 Possible connections It is possible to start or stop the pump with the external control potential free contact this function takes precedence over the other functions This external control...

Страница 12: ...Diagrams 2 4 3 6 3 2 1 4 2 1 5 3 1 6 3 1 4 3 1 7 3 1 5 4 ATTENTION Operating modes Mode 1 Mode 3 0 20 mA Mode 3 0 10 V Mode 2 PI control sensor 4 20 mA Mode 2 PI control sensor 0 10 V Mode 2 PI contro...

Страница 13: ...0 10 Sensor 0 10 V Input voltage V Pressure in of the sensor measurement range 100 0 2 20 Setpoint 0 20 mA Range in which the frequency converter stops Input current level mA Pressure in of the senso...

Страница 14: ...ons concerning commissioning see instruction manual for the pressure boosting sys tem During normal operation the status of the LEDs is as follows see Fig 9 Pos 17 18 6 2 Preparatory flushing Because...

Страница 15: ...he specification on the pump shield 7 Maintenance The pump s must be de energised and all non authorised restarts must be pre vented before any maintenance work is done Never undertake maintenance wor...

Страница 16: ...cannot be rectified then please contact your local professional tradesmen or the Wilo after sales service in your vicinity ATTENTION Display Frequency converter behaviour Fault possible causes Elimina...

Страница 17: ...as not been maintained b The suction line has a smaller circ umference than that of the pump c Suction strainer and suction line are partially blocked a Check correct setting of the nominal values set...

Страница 18: ...1008 EG Electromagnetic compatibility directive Compatibilit lectromagn tique directive Niederspannungsrichtlinie 2006 95 EG Low voltage directive Direction basse tension Angewendete harmonisierte No...

Страница 19: ...EMV Elektromagnetisk kompatibilitet 2004 1008 EG EG Lavspenningsdirektiv 2006 95 EG Anvendte harmoniserte standarder s rlig 1 FIN CE standardinmukaisuusseloste Ilmoitamme t ten ett t m laite vastaa s...

Страница 20: ...lint Budapest T 36 23 889500 wilo wilo hu Ireland WILO Engineering Ltd Limerick T 353 61 227566 sales wilo ie Italy WILO Italia s r l 20068 Peschiera Borromeo Milano T 39 25538351 wilo italia wilo it...

Страница 21: ...63 Dortmund T 0231 4102 7900 T 01805 W I L O K D 9 4 5 6 5 3 F 0231 4102 7126 Erreichbar Mo Fr von 7 17 Uhr Wochenende und feiertags 9 14 Uhr elektronische Bereitschaft mit R ckruf Garantie Kundendien...

Отзывы: