Wilo Helix V 22 Скачать руководство пользователя страница 5

A

A

A

D

E

C

AK

AK

AK

AG

AG

AJ

AJ

AJ

AG

AH

AH

AH

B

C
B

C
B

D E

D

E

F

F

F

Fig. 4

Type

(mm) 

A B C D E

F

G

H

J

K

Helix V 22

PN16/PN25/

PN30

130 296 215 250 300 90 DN50 125 4 x M16

16 x 

Ø14

Helix V 36

PN16

170

or

220

296

240

or

220

250 320 105 DN65 145

4 x M16

PN25/PN30

8 x M16

Helix V 52

PN16/PN25/

PN30

190

or

220

296

266

or

220

250 365 140 DN80 160 8 x M16

Type

(mm) 

A B C D E

F

G

H

J

K

Helix FIRST 

V22

PN16/PN25/

PN30

130 260 215 226 300 90 DN50 125 4 x M16

4 x Ø14

Helix FIRST 

V36

PN16

170 294 240 226 320 105 DN65 145

4 x M16

PN25PN30

8 x M16

Helix FIRST 

V52

PN16/PN25/

PN30

190

or

170

295

266

or

240

226 365 140 DN80 160 8 x M16

Type

(mm) 

A B C D E

F

G

H

J

K

Helix V 22

PN16/PN25 130 255 215 226 300 90 DN50 125 4 x M16

4 x Ø14

Helix V 36

PN16

170 284 240 230 320 105 DN65 145

4 x M16

PN25

8 x M16

Helix V 52

PN16/PN25

190

or

170

310

266

or

240

234 365 140 DN80 160 8 x M16

Material code -2 -3

Material code -4 -5

Material code -1

Содержание Helix V 22

Страница 1: ...la o e funcionamento tr N vod k mont i a obsluze el sv I no Paigaldus ja kasutusjuhend fi Uzst d anas un ekspluat cijas instrukcija da Montavimo ir naudojimo instrukcija hu Be p t si s zemeltet si uta...

Страница 2: ...Fig 1 FIRST...

Страница 3: ...Fig 2...

Страница 4: ...Fig 3 Fig 6 Fig 7 Fig 5 HIGH VOLTAGE LOW VOLTAGE L1 L2 L3 W1 V2 U2 W2 U1 V1 L1 L2 L3 L1 L2 L3...

Страница 5: ...A B C D E F G H J K Helix FIRST V22 PN16 PN25 PN30 130 260 215 226 300 90 DN50 125 4 x M16 4 x 14 Helix FIRST V36 PN16 170 294 240 226 320 105 DN65 145 4 x M16 PN25PN30 8 x M16 Helix FIRST V52 PN16 P...

Страница 6: ...Fig 8...

Страница 7: ...riate qualification for this work 2 3 Risks incurred by failure to comply with the safety instructions Failure to comply with the safety precautions could result in personal injury or damage to the pu...

Страница 8: ...l oil solid or abrasive substances or materials having long fibres The manufacturer s approval is required for use to pump corrosive chemicals CAUTION Risk of explosion Do not use this pump to handle...

Страница 9: ...p See pump nameplate to know the maximum operating pressure Pmax Temperature range Liquid temperatures 20 C to 120 C 30 C to 120 C if full stainless steel 15 C to 90 C Viton version for O ring and mec...

Страница 10: ...G Electrical shock hazard Dangers caused by electrical energy must be excluded 7 1 Commissioning Unpack the pump and dispose of the packaging in an environmentally responsible manner 7 2 Installation...

Страница 11: ...pump design it is recom mended to connect the hydraulic network and then keep out the plastic fixation links to pre vent any leakage risk 7 4 Motor connection for bare shaft pump without motor Remove...

Страница 12: ...s open completely the drain priming plug and the air bleed screw Service life 10 years depending on the operating conditions and whether all requirements described in the operation manual have been me...

Страница 13: ...uct NOTE The pump must not be disposed of along with household waste Further information on recycling can be found at www wilo recycling com Subject to technical alterations Defects Causes Remedies Pu...

Страница 14: ...2785961 info wilo kz Korea WILO Pumps Ltd 618 220 Gangseo Busan T 82 51 950 8000 wilo wilo co kr Latvia WILO Baltic SIA 1019 Riga T 371 6714 5229 info wilo lv Lebanon WILO LEBANON SARL Jdeideh 1202 2...

Страница 15: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...