10. Defects ­ causes ­ remedies

WARNING! Electrical shock hazard! 
Dangers caused by electrical energy must be excluded. 
All electrical work must be performed after the 
electrical supply has been switched off and 
secured against unauthorized switching.

WARNING! Risk of scalding! 
At high water temperatures and system pressure 
close isolating valves before and after the pump. 
First, allow pump to cool down.

If the fault cannot be solved, please 

contact WILO customer services.

11. Spare parts

All spare parts must be ordered through WILO 
Customer Services.
In order to avoid any mistakes, please specify the 
name plate data for orders.
Spare parts catalogue is available at www.wilo.
com.

12. Safe disposal

Proper disposal and recycling of this product 
prevents damage to the environment and risks to 
personal health.
Disposal in accordance with the regulations 
requires the product to be drained and cleaned.
Lubricants must be collected. The pump compo-
nents are to be separated according to material 
(metal, plastic, electronics).
1. Use public or private disposal organizations 
when disposing of all or part of the product.
2. For more information on proper disposal, please 
contact your local
council or waste disposal office or the supplier 
from whom you obtained the product.

NOTE:  The pump must not be disposed of along with 
household waste. Further information on recycling 
can be found at www.wilo-recycling.com.

Subject to technical alterations!

Defects 

Causes

Remedies

Pump fails to operate

No current

Check the fuses, the wiring, and the 
connectors

The thermistor tripping device has trip-
ped out, cutting off power

Eliminate any cause of overloading of the 
motor

Pump runs but delivers too little

Wrong direction of rotation

Check the direction of rotation of the 
motor and correct it if necessary

Parts of the pump are obstructed by for-
eign bodies

Check and clean the pipe

Air in suction pipe

Make the suction pipe airtight

Suction pipe too narrow

Install a larger suction pipe

The valve is not open far enough

Open the valve properly

Pump delivers unevenly

Air in pump

Evacuate the air in the pump; check that 
the suction pipe is airtight. If required, 
start the pump 20-30s – open the air 
bleed screw in order to move air away 
– close the air bleed screw and repeat it 
several times until no more air is going 
out of the pump

Pump vibrates or is noisy

Foreign bodies in pump

Remove the foreign bodies

Pump not properly attached to ground

Retighten the screws

Bearing damaged

Call WILO Customer Service

Motor overheats. Its protection trips out A phase is open-circuit

Check the fuses, the wiring, and the 
connectors

Ambient temperature too high

Provide cooling

Mechanical seal is leaking

Mechanical seal is damaged

Replace the mechanical seal

Содержание Helix V 22

Страница 1: ...la o e funcionamento tr N vod k mont i a obsluze el sv I no Paigaldus ja kasutusjuhend fi Uzst d anas un ekspluat cijas instrukcija da Montavimo ir naudojimo instrukcija hu Be p t si s zemeltet si uta...

Страница 2: ...Fig 1 FIRST...

Страница 3: ...Fig 2...

Страница 4: ...Fig 3 Fig 6 Fig 7 Fig 5 HIGH VOLTAGE LOW VOLTAGE L1 L2 L3 W1 V2 U2 W2 U1 V1 L1 L2 L3 L1 L2 L3...

Страница 5: ...A B C D E F G H J K Helix FIRST V22 PN16 PN25 PN30 130 260 215 226 300 90 DN50 125 4 x M16 4 x 14 Helix FIRST V36 PN16 170 294 240 226 320 105 DN65 145 4 x M16 PN25PN30 8 x M16 Helix FIRST V52 PN16 P...

Страница 6: ...Fig 8...

Страница 7: ...riate qualification for this work 2 3 Risks incurred by failure to comply with the safety instructions Failure to comply with the safety precautions could result in personal injury or damage to the pu...

Страница 8: ...l oil solid or abrasive substances or materials having long fibres The manufacturer s approval is required for use to pump corrosive chemicals CAUTION Risk of explosion Do not use this pump to handle...

Страница 9: ...p See pump nameplate to know the maximum operating pressure Pmax Temperature range Liquid temperatures 20 C to 120 C 30 C to 120 C if full stainless steel 15 C to 90 C Viton version for O ring and mec...

Страница 10: ...G Electrical shock hazard Dangers caused by electrical energy must be excluded 7 1 Commissioning Unpack the pump and dispose of the packaging in an environmentally responsible manner 7 2 Installation...

Страница 11: ...pump design it is recom mended to connect the hydraulic network and then keep out the plastic fixation links to pre vent any leakage risk 7 4 Motor connection for bare shaft pump without motor Remove...

Страница 12: ...s open completely the drain priming plug and the air bleed screw Service life 10 years depending on the operating conditions and whether all requirements described in the operation manual have been me...

Страница 13: ...uct NOTE The pump must not be disposed of along with household waste Further information on recycling can be found at www wilo recycling com Subject to technical alterations Defects Causes Remedies Pu...

Страница 14: ...2785961 info wilo kz Korea WILO Pumps Ltd 618 220 Gangseo Busan T 82 51 950 8000 wilo wilo co kr Latvia WILO Baltic SIA 1019 Riga T 371 6714 5229 info wilo lv Lebanon WILO LEBANON SARL Jdeideh 1202 2...

Страница 15: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: