WARNING! 
When the pumped liquid is hot and the pressure 
high, the stream escaping at the air bleed screw 
may cause burns or other injuries.

-  Open the guard valve on the discharge side com-

pletely (3).

-  Close the drain-priming plug (5a).

   8.2  Starting up

CAUTION!   
The pump must not operate at zero flow (closed 
discharge valve).

WARNING! Risk of injury! 
When the pump runs, coupling guards must be in 
place, tightened with all appropriate screws.

WARNING! Important noise! 
Noise emitted by most powerful pumps could be 
very high : protection must be used in case of long 
stay close to the pump.

WARNING!  
Installation must be designed in order that no one 
could be hurt in case of fluid leakage (mechanical 
seal failure …).

9. Maintenance ­ Service

All servicing should be performed by an autho­

rized service representative!
WARNING!  Electrical shock hazard! 
Dangers caused by electrical energy must be 
excluded. 
All electrical work must be performed after the 
electrical supply has been switched off and 
secured against unauthorized switching.

WARNING!  Risk of scalding! 
At high water temperatures and system pressure 
close isolating valves before and after the pump. 
First, allow pump to cool down.

-  These pumps are maintenance free. Nevertheless 

a regular check is recommended every 15 000 
hours.

-  Optionally, the mechanical seal for certain 

models can be replaced easily thanks to its car-
tridge design.

-  In case of pump with half flanges design and ins-

tallation again after maintenance operation, it is 
suggested to add plastic link to maintain in easy 
way the half flanges together.

-  For pumps equipped with one grease feeder (Fig. 

7, pos. 1), respect lubrication frequences menti-
oned on sticker glued on lantern part (2).

-  Insert its adjusting wedge in its housing (Fig. 6) 

once mechanical seal position is set.

-  Always keep the pump perfectly clean. 
-  Pumps which are not being used during periods 

of frost should be drained to avoid damage: 
Close the guard valves, open completely the 
drain-priming plug and the air bleed screw.

-  Service life : 10 years depending on the operating 

conditions and whether all requirements described 
in the operation manual have been met.

20

English

8. Start up

   8.1  System filling ­ Venting

CAUTION! Possible damage of the pump!  
Never operate the pump dry.
The system must be filled before starting the 
pump.

  8.1.1  Air evacuation process – Pump with sufficient 

supply pressure (Fig. 3)

-  Close the two guard valves (2, 3).
-  Unscrew the air bleed screw from filling plug 

(6a).

-  Slowly open the guard valve on the suction side 

(2).

-  Retighten the air-bleed screw when air escapes 

at the air bleed screw and the pumped liquid 
flows (6a). 

WARNING!  
When the pumped liquid is hot and the pressure 
high, the stream escaping at the air bleed screw 
may cause burns or other injuries. 

-  Open the guard valve on the suction side com-

pletely (2).

-  Start the pump and check if direction of rotation 

matches the one printed on pump plating. If this 
is not the case, interchange 2 phases in the ter-
minal box.

CAUTION!   
A wrong direction of rotation will cause bad 
pump performances and possibly coupling 
damage.

-  Open the guard valve on the discharge side (3).

  8.1.2  Air evacuation process – Pump in suction  

(Fig. 2) 

-  Close the guard valve on the discharge side (3). 

Open the guard valve on the suction side (2).

-  Remove the filling plug with air bleed screw (6b). 
-  Open the drain-priming plug not completely 

(5b).

-  Fill the pump and the suction pipe with water. 
-  Make sure that there is no air in the pump and in 

the suction pipe : refilling until complete removal 
of air is required.

-  Close the filling plug with air bleed screw (6b).
-  Start the pump and check if direction of rotation 

matches the one printed on pump plating. 

If this 

is not the case, interchange two phases in the 
terminal box.

CAUTION!   
A wrong direction of rotation will cause bad 
pump performances and possibly coupling 
damage.

-  Open the guard valve on the discharge side a 

little (3).

-  Unscrew the air bleed screw from filling plug for 

air venting (6a).

-  Retighten the air-bleed screw when air escapes 

at the air bleed screw and the pumped liquid 
flows.

WILO SE 03/2016

Содержание Helix V 22

Страница 1: ...la o e funcionamento tr N vod k mont i a obsluze el sv I no Paigaldus ja kasutusjuhend fi Uzst d anas un ekspluat cijas instrukcija da Montavimo ir naudojimo instrukcija hu Be p t si s zemeltet si uta...

Страница 2: ...Fig 1 FIRST...

Страница 3: ...Fig 2...

Страница 4: ...Fig 3 Fig 6 Fig 7 Fig 5 HIGH VOLTAGE LOW VOLTAGE L1 L2 L3 W1 V2 U2 W2 U1 V1 L1 L2 L3 L1 L2 L3...

Страница 5: ...A B C D E F G H J K Helix FIRST V22 PN16 PN25 PN30 130 260 215 226 300 90 DN50 125 4 x M16 4 x 14 Helix FIRST V36 PN16 170 294 240 226 320 105 DN65 145 4 x M16 PN25PN30 8 x M16 Helix FIRST V52 PN16 P...

Страница 6: ...Fig 8...

Страница 7: ...riate qualification for this work 2 3 Risks incurred by failure to comply with the safety instructions Failure to comply with the safety precautions could result in personal injury or damage to the pu...

Страница 8: ...l oil solid or abrasive substances or materials having long fibres The manufacturer s approval is required for use to pump corrosive chemicals CAUTION Risk of explosion Do not use this pump to handle...

Страница 9: ...p See pump nameplate to know the maximum operating pressure Pmax Temperature range Liquid temperatures 20 C to 120 C 30 C to 120 C if full stainless steel 15 C to 90 C Viton version for O ring and mec...

Страница 10: ...G Electrical shock hazard Dangers caused by electrical energy must be excluded 7 1 Commissioning Unpack the pump and dispose of the packaging in an environmentally responsible manner 7 2 Installation...

Страница 11: ...pump design it is recom mended to connect the hydraulic network and then keep out the plastic fixation links to pre vent any leakage risk 7 4 Motor connection for bare shaft pump without motor Remove...

Страница 12: ...s open completely the drain priming plug and the air bleed screw Service life 10 years depending on the operating conditions and whether all requirements described in the operation manual have been me...

Страница 13: ...uct NOTE The pump must not be disposed of along with household waste Further information on recycling can be found at www wilo recycling com Subject to technical alterations Defects Causes Remedies Pu...

Страница 14: ...2785961 info wilo kz Korea WILO Pumps Ltd 618 220 Gangseo Busan T 82 51 950 8000 wilo wilo co kr Latvia WILO Baltic SIA 1019 Riga T 371 6714 5229 info wilo lv Lebanon WILO LEBANON SARL Jdeideh 1202 2...

Страница 15: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: