Wilo Helix V 22 Скачать руководство пользователя страница 11

19

English

-  Place the pump where it will be easy to reach, to 

facilitate inspection and removal work. The pump 
must always be installed perfectly upright on a 
sufficiently heavy concrete base.

CAUTION!  Risk of parts inside the pump!  
Take care to remove closure members of the 
pump housing before installation.

NOTE: Each pumps could be tested regarding 
hydraulic features in factory, some water may 
remain in them. It is recommended for hygienic 
purposes, to carry out a rinsing of the pump 
before any using with potable water supply.

-  The installation and connection dimensions are 

given § 5.2.

-  Lift the pump carefully by using the integrated 

hooks rings, if necessary with a hoist and suitable 
slings according to the current hoist guidelines.

WARNING!  Risk of fall! 
Take care to pump fixations especially for the 
highest pumps whose centre of gravity may lead 
to risk during pump handling.

WARNING!  Risk of fall! 
Use integrated rings only if they are not damaged 
(no corrosion ...). Replace them if needed.

WARNING!  Risk of fall! 
The pump must be never carried by using motor 
hooks: these are only designed to lift the motor 
alone.

   7.3  Pipe connection

-  Connect the pump to the pipes by using approp-

riate counterflanges, bolts, nuts and gaskets.

CAUTION!  
Tightening of bolts must not exceed 80 Nm 
Use of impact wrench is prohibited.

-  The circulation sense of the fluid is indicated on 

the identification label of the pump.

-  Pump must be installed in such a way that it is 

not stressed by the pipework. The pipes must be 
attached so that the pump does not bear their 
weight.

-  It is recommended that isolation valves be ins-

talled on the suction and discharge side of the 
pump.

-  Use of expansion joints may mitigate noise and 

vibration of the pump.

-  As regards the nominal cross-section of the suc-

tion pipe, we recommend a cross-section at least 
as large as that of the pump connection.

-  A check valve could be placed on the discharge 

pipe in order to protect the pump against ham-
mer shock.

-  For direct connection to a public drinking water 

system, the suction pipe must also have a check 
valve and a guard valve. 

-  For indirect connection via a tank, the suction 

pipe must have a strainer to keep any impurities 
out of the pump and a check valve.

-  In case of half flanges pump design, it is recom-

mended to connect the hydraulic network and 

then keep out the plastic fixation links to pre-
vent any leakage risk.

   7.4  Motor connection for bare­shaft pump  

(without motor)

-  Remove coupling guards.

NOTE: Helix pumps are equipped with captive 
screws as required in the Machinery Directive.

-  Install the motor on the pump by using screws 

(FT lantern size – see product designation) or 
bolts, nuts and handling devices (FF lantern 
size – see product designation) provided with 
the pump : check motor power and dimension in 
WILO catalogue.

NOTE: Depending on fluid characteristics, 
motor power could be modified. Contact WILO 
Customer Services if needed.

-  Close the coupling guards by screwing all screws 

provided with the pump.

  7.5  Electrical connection

WARNING!  Electrical shock hazard! 
Dangers caused by electrical energy must be 
excluded. 

• 

Electrical work by a qualified electrician only!

• 

All electrical connections must be performed 

after the electrical supply has been switched off 
and secured against unauthorized switching.

• 

For safe installation and operation a proper 

grounding of the pump to the power supply’s 
grounding terminals is required.

-  Check that operating current, voltage and fre-

quency used comply with motor plating data.

-  The pump must be connected to the power sup-

ply by a solid cable equipped with a grounded 
plug-connection or a main power switch. 

-  Three-Phase motors must be connected to an 

approved motor starter. The set nominal current 
must correspond to the electrical data on the 
pump motor name plate  

-  The supply cable must be laid so that it never touches 

the pipework and/or the pump and motor casing.

-  The pump/installation should be grounded in 

compliance with local regulations. A ground fault 
interrupter can be used as extra protection.

-  The connection to the network must be in 

accordance with the connection plan (Fig. 5).

  7.6  Operation with frequency converter

-  Motors used can be connected to a frequency 

converter in order to adapt pump performance to 
duty point.

-  The converter must not generate voltage peaks 

at motor terminals higher than 850V and dU/dt  
slope higher than 2500 V/µs. 

-  In case of higher value, an appropriate filter must 

be used : contact converter manufacturer for this 
filter definition and selection.

-  Strictly follow instructions provided by the 

converter manufacturer data sheet for installation.

-  Minimum variable speed should not be set below 

40% of pump nominal speed.

WILO SE 03/2016

Содержание Helix V 22

Страница 1: ...la o e funcionamento tr N vod k mont i a obsluze el sv I no Paigaldus ja kasutusjuhend fi Uzst d anas un ekspluat cijas instrukcija da Montavimo ir naudojimo instrukcija hu Be p t si s zemeltet si uta...

Страница 2: ...Fig 1 FIRST...

Страница 3: ...Fig 2...

Страница 4: ...Fig 3 Fig 6 Fig 7 Fig 5 HIGH VOLTAGE LOW VOLTAGE L1 L2 L3 W1 V2 U2 W2 U1 V1 L1 L2 L3 L1 L2 L3...

Страница 5: ...A B C D E F G H J K Helix FIRST V22 PN16 PN25 PN30 130 260 215 226 300 90 DN50 125 4 x M16 4 x 14 Helix FIRST V36 PN16 170 294 240 226 320 105 DN65 145 4 x M16 PN25PN30 8 x M16 Helix FIRST V52 PN16 P...

Страница 6: ...Fig 8...

Страница 7: ...riate qualification for this work 2 3 Risks incurred by failure to comply with the safety instructions Failure to comply with the safety precautions could result in personal injury or damage to the pu...

Страница 8: ...l oil solid or abrasive substances or materials having long fibres The manufacturer s approval is required for use to pump corrosive chemicals CAUTION Risk of explosion Do not use this pump to handle...

Страница 9: ...p See pump nameplate to know the maximum operating pressure Pmax Temperature range Liquid temperatures 20 C to 120 C 30 C to 120 C if full stainless steel 15 C to 90 C Viton version for O ring and mec...

Страница 10: ...G Electrical shock hazard Dangers caused by electrical energy must be excluded 7 1 Commissioning Unpack the pump and dispose of the packaging in an environmentally responsible manner 7 2 Installation...

Страница 11: ...pump design it is recom mended to connect the hydraulic network and then keep out the plastic fixation links to pre vent any leakage risk 7 4 Motor connection for bare shaft pump without motor Remove...

Страница 12: ...s open completely the drain priming plug and the air bleed screw Service life 10 years depending on the operating conditions and whether all requirements described in the operation manual have been me...

Страница 13: ...uct NOTE The pump must not be disposed of along with household waste Further information on recycling can be found at www wilo recycling com Subject to technical alterations Defects Causes Remedies Pu...

Страница 14: ...2785961 info wilo kz Korea WILO Pumps Ltd 618 220 Gangseo Busan T 82 51 950 8000 wilo wilo co kr Latvia WILO Baltic SIA 1019 Riga T 371 6714 5229 info wilo lv Lebanon WILO LEBANON SARL Jdeideh 1202 2...

Страница 15: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: