English

8

WILO SE 10/2010

Please submit all the details on the unit's rating plate when ordering spare parts.

5.3 Scope of delivery

Sewage lifting unit, delivered on pallets in the assemblies:
2  pumps, complete, in horizontal installation
1  tank, complete (2 x for units with 2 tanks)
1 switchgear 

(3~400 

V)

1  Zener barrier in the housing with 1 m cable, pre-installed
1  level sensor 0-1 mwc, 10 m cable
1  set of fixation material for tank and pumps on the floor
1  DN 150 hose section with clamps for DN 150 inlet connection
1  DN 150 hose section with clamps for tank connection

(only for units with 2 tanks)

1  DN 75 hose section with clamps for connection of the ventilation line

(2 x for units with 2 tanks)

1  DN 50 hose section with clamps for connection of the suction line to the diaphragm 

hand pump (2 x for units with 2 tanks)

2  vent flanges with flat gaskets, DN 19 hose sections and hose clamps
1  Installation and operating instructions

5.4 Accessories

Accessories must be ordered separately. For a detailed list and description, see catalogue/
price list.
The following accessories are available:

• DN 80 cast gate valve for pressure pipe
• DN 100 cast gate valve, pressure pipe and pump suction pipe
• DN 80 cast non-return valve for pressure pipe
• DN 100 cast non-return valve for pressure pipe
• Flange pieces DN 80, DN 80/100, DN 100, for connection of the slide valve on the pressure 

side to the pressure pipe

• Y-pipe DN 80, DN 100 for units with 1 tank
• Plastic gate valve DN 100, DN for inlet pipe
• Diaphragm hand pump R 1½ (without hose)
• 3-way cock for switch-over to manual extraction from the pump sump/tank
• Alarm switchgear
• Horn 230 V/50 Hz 
• Flash light 230 V/50 Hz 
• Signal lamp 230 V/50 Hz

CE

WILO SE Dortmund

Nortkirchenstr. 100, 44263 Dortmund, Germany

10

EN 12050-1 

Faeces lifting unit for building DN 80, DN 100

Lifting power

- See pump curve

Noise level

- TRS

Explosion protection

- TRS

Corrosion protection

– coated, or corrosion-resistant 

materials, inox/composite

Содержание DrainLift XXL 1040-2/3.9

Страница 1: ...GB Installation and operating instructions Wilo DrainLift XXL 2 532 170 Ed 02 2010 10 Wilo...

Страница 2: ......

Страница 3: ...ng It is not only the general safety instructions listed under the main point safety that must be adhered to but also the special safety instructions with danger symbols included under the following m...

Страница 4: ...sheet 3 Transport and interim storage The unit and individual components are delivered on a pallet Immediately after receiving the product Check the product for damage in transit In the event of damag...

Страница 5: ...auses damage to the product The maximum possible inflow quantity must always be lower than the volume flow of a pump at the respective duty point Application limits The unit is not designed for perman...

Страница 6: ...ambient temperature C 40 Max solid grain size mm 80 95 Sound pressurelevel depending on the duty point 2 dB A 70 Gross volume l 400 Recommended level Pump 1 ON switching point 3 mm 560 Minimum value o...

Страница 7: ...ure C 3 Max ambient temperature C 40 Max solid grain size mm 80 95 Sound pressurelevel depending on the duty point 2 dB A 70 Gross volume l 800 Recommended level Switching point pump 1 ON 3 mm 560 Min...

Страница 8: ...ns and hose clamps 1 Installation and operating instructions 5 4 Accessories Accessories must be ordered separately For a detailed list and description see catalogue price list The following accessori...

Страница 9: ...in the tank with a 90 elbow facing the base of the tank This prevents deposits on the base to a great extent Likewise a lower residual water volume and a higher switching volume is achieved in this wa...

Страница 10: ...onal and regional regulations Observe the installation and operating instructions for the accessories Never pull the cable when installing the unit In particular the valid regional regulations e g in...

Страница 11: ...the tank to the floor so that it is anti buoyant after the curing of the mortar cartridges 140 110 14 100 Fig 4 Installation of the pumps Fix the pumps to the floor with the supplied fixation material...

Страница 12: ...al pipe sections since they contribute to fluid hammers of the non return valves and thus dangerous pressure surges that may exceed the permissible value and thus pose a risk to the unit and the press...

Страница 13: ...t the DN 70 connecting piece on the top of the tank Fig 6 Fig 7 Install the piping so that it can run empty of its own accord Connection of two tanks At units with two tanks the tanks have to be conne...

Страница 14: ...installation room for faeces lifting units Fig 9 Select the pump Pos 10 according to the delivery head of the unit The dimensions of the pit in the floor of the installation room should be at least 50...

Страница 15: ...power leads with K characteristic to be used Earth the unit according to regulations Lay the connecting cable in accordance with the applicable standards regulations and the wire assignments Provide a...

Страница 16: ...e level sensor must be wired directly with the Zener barrier Undo the housing screws and remove the cover Feed the cable ends from the level sensor through the cable bushing Connect the cable ends in...

Страница 17: ...AUTION Risk of property damage If the venting screw of the non return valve is screwed too deep into the housing this may cause damage to the valve and unit or considerable noise Make sure the positio...

Страница 18: ...tion level is set higher than the inlet height there will be a risk of backflow in the connected objects 8 2 3 Adjustment of the follow up time The pump follow up time is to be set in the Follow up me...

Страница 19: ...pair work Have work on the electrical part of the unit carried out only by a qualified electrician as a basic principle DANGER Toxic or harmful substances in sewage can cause infections or suffocation...

Страница 20: ...ion of rotation Swap two phases of the current feed 3 Wear to inner parts impeller bearing Replace worn parts 4 Operating voltage too low 5 Running on two phases only with 3 version Replace defective...

Страница 21: ...ted for each order 12 Disposal Damage to the environment and risks to personal health are avoided by the proper disposal and appropriate recycling of this product 1 Draw on public or private waste man...

Страница 22: ...x 22 WILO SE 10 2010 Anhang Appendix Annexe Za cznik Fig 2 DrainLift XXL 840 75 880 200 180 815 700 238 500 260 180 1470 1550 DN 80 DN 100 850 200 190 31 788 463 1345 1965 780 170 170 500 930 110 160...

Страница 23: ...ppendix Wilo DrainLift XXL 23 Fig 2 DrainLift XXL 880 75 880 200 815 700 DN 80 DN 100 850 200 190 31 788 463 1345 1965 180 238 500 260 180 1470 1550 560 170 170 1620 60 560 840 1695 110 160 110 160 11...

Страница 24: ...Appendix 24 WILO SE 10 2010 Fig 2 DrainLift XXL 1040 75 880 200 180 815 700 260 547 300 190 1650 DN 100 850 200 190 31 788 463 1355 1990 780 170 170 500 960 110 160 110 160...

Страница 25: ...Appendix Wilo DrainLift XXL 25 Fig 2 DrainLift XXL 1080 75 880 200 815 700 DN 100 850 200 190 31 788 463 1355 1990 180 260 547 300 190 1650 560 170 170 1620 60 560 840 1710 110 160 110 160 110...

Страница 26: ...protection de la directive basse tension 2006 95 CE sont respect es conform ment appendice I n o 1 5 1 de la directive CE relatives aux machines 2006 42 CE Elektromagnetische Vertr glichkeit Richtlin...

Страница 27: ...S pro strojn za zen 2006 42 ES dyrektyw maszynow WE 2006 42 WE EC 2006 42 EG C le t kaj c se bezpe nosti stanoven ve sm rnici o elektrick ch za zen ch n zk ho nap t jsou dodr eny podle p lohy I 1 5 1...

Страница 28: ...dapest T 36 23 889500 wilo wilo hu India WILO India Mather and Platt Pumps Ltd Pune 411019 T 91 20 27442100 service pun matherplatt co in Indonesia WILO Pumps Indonesia Jakarta Selatan 12140 T 62 21 7...

Страница 29: ...henstra e 100 44263 Dortmund T 0231 4102 7900 T 01805 W I L O K D 9 4 5 6 5 3 F 0231 4102 7126 kundendienst wilo com T glich 7 18 Uhr erreichbar 24 Stunden Technische Notfallunterst tzung Kundendienst...

Отзывы: