10. Problems, causes and remedies
If no solution can be found, please
contact your plumbing and hea-
ting specialist or your nearest Wilo
Customer Service or representative.
11. Spare parts
Spare parts are ordered via a local specialist dealer
and/or Wilo customer service.
In order to avoid queries and incorrect orders,
make sure to mention all data indicated on the
rating plate when placing your order.
12. Disposal
Information on the collection of used electrical
and electronic products
Proper disposal and appropriate recycling of this
product prevents damage to the environment
and dangers to your personal health.
NOTICE: Disposal in domestic waste is forbid-
den !
In the European Union, this symbol can appear
on the product, the packaging or the accompa-
nying documentation. It means that the electrical
and electronic products in question must not be
dis- posed of along with domestic waste.
To ensure proper handling, recycling and disposal
of the used products in question, please note the
following points:
• Only hand over these products at designated,
certified collecting points.
• Observe the locally applicable regulations!
Please consult your local municipality, the near-
est waste disposal site, or the dealer who sold
the product to you for information on proper
disposal. For further information on recycling, go
to www.wilo-recycling.com.
Subjet to technical modifications!
Problems
Causes
remedy
Pump does not run
Interruption of the current, short circuit.
Insulation fault in the motor winding
Check power supply,
Call on expert to check cable and motor
Safety fuse, capacitor defect
Replace fuses, capacitor
Cable break
Check cable resistance. If necessary,
replace cable. Only use original Wilo spe-
cial cable!
Protective motor switch
engaged
Protective motor switch not set cor-
rectly
Switch to nominal current
Cutting device or impeller already
blocked by foreign bodies
• Switch off the pump voltage and secure
against re-operation
• Close the shut-off valve at the back of
the pump
• Remove pump from the sump
• Remove foreign bodies from the pump
Pump does not pump
Air in spiral housing
Ventilate backflow preventer
Level switch not set correctly
Ensure that the suction impeller is floo-
ded
WILO SE 03/2017
English
25
Содержание Drain TS 40
Страница 49: ...10 WILO Service WILO 11 Wilo WILO WSK WILO SE 03 2017 12 www wilo recycling com 49...
Страница 76: ...76 7 1 2 7 2 EVU VDE 16 A 30 3 3 400V DM 4 4 x 1 02 U V W PE 8 8 1 2 8 2 2 2a S3 2b S1 9 WILO SE 03 2017...
Страница 77: ...1 1 21 5 2 10 Wilo 11 Wilo 12 www wilo recycling com WILO WILO SE 03 2017 77...
Страница 82: ......