NOTICE
• Depending on the system impedance and the maximum connections/
hour of the connected consumers, voltage fluctuations and/or drops
may occur.
• When using shielded cables, attach the shielding to the earth rail on
one side of the switchgear!
• Always have connection carried out by a qualified electrician!
• Observe the installation and operating instructions for the connected
pumps and signal transmitters.
1~230 V, 2-pole, direct starting
Power in kW
System impedance in ohm
Connections/h
1.5
0.4180
6
1.5
0.3020
24
1.5
0.2720
30
2.2
0.2790
6
2.2
0.1650
24
2.2
0.1480
30
3~400 V, 2-pole, direct starting
Power in kW
System impedance in ohm
Connections/h
2.2
0.2788
6
2.2
0.2126
24
2.2
0.1915
30
3.0
0.2000
6
3.0
0.1292
24
3.0
0.1164
30
4.0
0.1559
6
4.0
0.0889
24
4.0
0.0801
30
3~400 V, 4-pole, direct starting
Power in kW
System impedance in ohm
Connections/h
2.2
0.2330
24
2.2
0.2100
30
3.0
0.2090
6
3.0
0.1380
24
3.0
0.1240
30
4.0
0.1480
6
4.0
0.0830
24
4.0
0.0740
30