Fuse defective
Check fuses and replace if necessary
Motor protection has triggered
Check the default values against the pump
or motor data, measure the current values
and correct the setting if necessary. Check
the motor for defects and replace it if nec-
essary.
Contactor defective
Check it and replace it if necessary.
Turn-to-turn fault in the motor
Check, if necessary replace motor or have
repaired.
Pump does not shut down.
Strongly fluctuating inlet pressure
Check the inlet pressure and take measures
to stabilise the inlet pressure if necessary
(e.g. pressure reducers).
Intake pipe blocked or shut off
Check the inlet pipe and remove the block-
age or open the shut-off device if neces-
sary.
Nominal diameter of the inlet pipe too
small
Check the inlet pipe and increase the cross-
section of the inlet pipe if necessary.
Inlet pipe installed incorrectly
Check the inlet pipe and change the pipe
routing if necessary.
Air in the inlet
Check and shut off the piping and vent the
pumps if necessary.
Impellers blocked
Check the pump and replace it or have it
repaired if necessary.
Non-return valve leaking
Check and replace the seal or non-return
valve if necessary.
Non-return valve blocked
Check and remove the blockage or replace
the non-return valve if necessary.
Gate valve in the system closed or not
sufficiently open
Check and open the shut-off device com-
pletely if necessary.
Flow rate too high
Check the pump data and default values
and correct them if necessary.
Shut-off device closed at pressure sensor Check and open the shut-off device if nec-
essary.
Switch-off pressure set too high
Check the setting and correct it if neces-
sary.
Incorrect direction of rotation of the
motor
Check the direction of rotation and repair or
replace the frequency converter module if
necessary.
Switching frequency too high or flut-
tering
Major fluctuations of the inlet pressure
Check the inlet pressure and take measures
to stabilise the inlet pressure if necessary
(e.g. pressure reducers).
Intake pipe blocked or shut off
Check the inlet pipe and remove the block-
age or open the shut-off device if neces-
sary.
Nominal diameter of the inlet pipe too
small
Check the inlet pipe and increase the cross-
section of the inlet pipe if necessary.
Inlet pipe installed incorrectly
Check the inlet pipe and change the pipe
routing if necessary.
Shut-off device closed at pressure sensor Check and open the shut-off device if nec-
essary.
Incorrect supply pressure at diaphragm
pressure vessel
Check the supply pressure and correct it if
necessary.
Valve at diaphragm pressure vessel
closed
Check the valve and open it if necessary.
Switching difference set too low
Check the setting and correct it if neces-
sary.
Pump not stable and/or making
unusual noises
Major fluctuations of the inlet pressure
Check the inlet pressure and take measures
to stabilise the inlet pressure if necessary
(e.g. pressure reducers).
Intake pipe blocked or shut off
Check the inlet pipe and remove the block-
age or open the shut-off device if neces-
sary.
Fault
Cause
Remedy
Содержание Comfort-Vario COR-1***-/VR Series
Страница 2: ...Fig 1a Fig 1b 3 1 4 5 7 8 9 12 11 14 15 17 10 16 3 1 4 5 7 8 9 12 11 14 15 17 10 16 6...
Страница 3: ...Fig 1c 3 1 4 5 7 8 9 12 11 14 15 17 10 16 Fig 1d 3 1 5 7 8 9 12 11 14 15 17 10 16 4 6...
Страница 4: ...Fig 1e 3 1 4 5 7 8 9 12 11 14 15 17 10 16 Fig 1f 3 1 4 5 7 8 9 12 11 14 15 17 10 13 2...
Страница 5: ...Fig 2 11 18 12a 19 9 10 12b 12b...
Страница 6: ...Fig 3 OPEN CLOSED 9 10 A B C...
Страница 7: ...Fig 4...
Страница 8: ...Fig 5a 14a 14b 14 1 14 4 14 2 14 3 14 5 14 6 14 8 14 9 14 7 14 10...
Страница 9: ...Fig 5b 14 2 23a 23b 14 1...
Страница 10: ...Fig 6a 20 21 24 22 23 25 26 29 29 Fig 6b 20 23 27 28 25 26 29 21 24...
Страница 11: ...Fig 7 RB 30 31 32 30 32 34 33 31 33 16 16...
Страница 12: ...Fig 8a x2 36 37 38 39 42 41 40 35...
Страница 13: ...Fig 8b x4 x4 x4 oder x6 36 37 42 2 38 35 39 34 35 41 40...
Страница 14: ...Fig 9a 44 45 49 50 43 50 47 48 46...
Страница 15: ...Fig 9b 52...
Страница 16: ......
Страница 21: ...English Installation and operating instructions Wilo SiBoost Smart 1 Wilo Comfort Vario COR 1 GE VR 29...
Страница 39: ...English Installation and operating instructions Wilo SiBoost Smart 1 Wilo Comfort Vario COR 1 GE VR 47...
Страница 40: ......