background image

14

Spares 2 EC-EM

29992800 CA

T5 

1MHI202/E

C-EM-2

29992801 CA

T5 

1MHI203/E

C-EM-2

29992802 CA

T5 

1MHI204/E

C-EM-2

29992803 CA

T5 

1MHI205/E

C-EM-2

29992804 CA

T5 

1MHI206/E

C-EM-2

29992805 CA

T5 

1MHI402/E

C-EM-2

29992806 CA

T5 

1MHI403/E

C-EM-2

29992807 CA

T5 

1MHI404/E

C-EM-2

29992808 CA

T5 

1MHI405/E

C-EM-2

29992809 CA

T5 

1MHI406/E

C-EM-2

Pumps

4024283

MHi202-1/E/3

4024285

MHi203-1/E/3

4024287

MHi204-1/E/3

4210718

MHi205-1/E/3

4210722

MHi206-1/E/3

4024293

MHi402-1/E/3

4024295

MHi403-1/E/3

4210725

MHi404-1/E/3

4210732

MHi405-1/E/3

4210735

MHi406-1/E/3

Vessel

2815472

8L Expansion Vessel

Controls

2818575

Low Water Switch

4160334

Water Cooled Inverter

2818472

Isolator

Valves

2818409

1/2" Inlet Valve (float inc.)

2819156

1" Isolation Valve

2520853

3/4" Vessel Valve

2818056

1” Non Return Valve

For all spares enquiries please contact [email protected]

Содержание 2819142

Страница 1: ...819146 CAT5 1MHI206 PS EM 29992804 CAT5 1MHI206 EC EM 2 2819147 CAT5 1MHI402 PS EM 29992805 CAT5 1MHI402 EC EM 2 2819148 CAT5 1MHI403 PS EM 29992806 CAT5 1MHI403 EC EM 2 2819149 CAT5 1MHI404 PS EM 299...

Страница 2: ...s 4 4 4 2 Operating Features 4 5 Installation 5 1 Hydraulic Connections 4 5 2 Electrical Connections 4 6 Commissioning 6 1 Commissioning 5 6 2 Maintenance 5 7 Warranty 5 8 Figures Fig 1 MHI PS EM Elec...

Страница 3: ...ifficulty is mentioned 2 2 Modification and Spare Parts Modifications to the booster are prohibited and will invalidate the warranty Wilo Approved spares must be used at all times For information on s...

Страница 4: ...set level to stop air from entering the pump Programmable electronic menu with alarm log and run timer Table 2 4 4 MHIE EM Single Phase Variable Speed 4 4 1 Operating Mode MHIE EM is a variable speed...

Страница 5: ...recommend that the expansion vessel is checked at least annually This may require more frequent checks if the unit is subject to higher frequencies of use Checks should be made on condition of stored...

Страница 6: ...6 Fig 1 MHI PS EM Electrical Connections Fig 2 MHIE DM Electrical Connections 8 Figures...

Страница 7: ...7 Fig 3 MHI EC EM Fig 4 MHIE EM Electrical Connections...

Страница 8: ...8 Fig 5 General Arrangement Hydraulic Fig 6 PS EM Layout...

Страница 9: ...9 Fig 7 MHIE EM DM Layout Fig 8 MHIE EM Controls...

Страница 10: ...10 Manual Mode Inverter On Green LED Automatic Mode Alarm Red LED Menu Pump Running Yellow LED Enter Pump in Automatic Mode Green LED Table 1 Driver User Interface EC EM Fig 9 MHI EC EM Layout...

Страница 11: ...ressure before the pumps start 0 3 Bar Time Before Stop Time the pumps will run once the pressure has been reached at no flow 15 Sec MENU HISTORIC Running Time Total pump running hours Hrs Pump Cycles...

Страница 12: ...technical service depart ment E031 OVER T If the temperature is too high the controller will stop the motor from running Check that the water temperature does not exceed 40 C Check that the ambient te...

Страница 13: ...1 230 4024288 MHi205 1 E 1 230 4024290 MHi206 1 E 1 230 4024292 MHi402 1 E 1 230 4024294 MHi403 1 E 1 230 4024296 MHi404 1 E 1 230 4024298 MHi405 1 E 1 230 4024300 MHi406 1 E 1 230 4148406 MHIE205N 1...

Страница 14: ...2 Pumps 4024283 MHi202 1 E 3 4024285 MHi203 1 E 3 4024287 MHi204 1 E 3 4210718 MHi205 1 E 3 4210722 MHi206 1 E 3 4024293 MHi402 1 E 3 4024295 MHi403 1 E 3 4210725 MHi404 1 E 3 4210732 MHi405 1 E 3 421...

Страница 15: ...Electromagnetic Compatibility Directive WEEE Directive ROHS Directive As well as following harmonized standards If the above mentioned series are technically modified without our approval this declar...

Страница 16: ......

Отзывы: