Maintenance
en
Installation and operating instructions Wilo-RAIN1
29
ƒ
Open the city main water inlet and wait for the break tank filling.
ƒ
Plug in the power supply socket and switch on the system.
ƒ
Use the interface of the controller (see chapter 6.3) to switch to the manual/main
water mode. The pump and the suction pipes are filling up with water.
ƒ
Select automatic running mode.
ƒ
Open successively all taps or water outlets of the installation in order to remove all
the residual air. The pump should turn on during this step. Otherwise, the controller
switches to the failure mode. Acknowledge the failure until the pump is completely
primed.
ƒ
Close all taps of the installation and check the water tightness of the system.
The product is ready to run.
9
Maintenance
Only qualified personnel is authorized to performed maintenance work and repairs.
DANGER
Death hazard!
Death hazard by electrocution during work on the electrical devices.
In order to do maintenance work and repairs, the device/installation must be turned
off and secured against being inadvertently switched on.
In a general matter, only a qualified electrician or installer is authorized to repair the
damaged connecting cables.
A yearly control of the installation by an after-sales service is recommended. The pump
does not require any maintenance. At least once a year, it is recommended to control
the water tightness of the installation.
If the system is not used for a long period, it is recommended to close the city main wa-
ter inlet, unplug the socket to cut the power and drain the complete installation. Use
the lower hole of the pump to drain it. Check the step 2 of chapter 7.3 for the break
tank drainage process.
10
Faults, causes and remedies
DANGER
Health hazard!
Repair work may only be carried out by qualified personnel! Respect the safety in-
structions in chapter 9.
Faults
Causes
Remedies
The pump does not start
No electrical power supply
Control the fuses/circuit breakers on the electric
board, the connections and the power supply
cable and then restart the system.
The pump does not deliver
the suction head is too high
Check the water level in the rainwater storage
tank.
Pressure too low
Suction head too high
Clean the filter or the strainer of the foot valve in
the rainwater storage.
Suction filter/strainer/foot valve clogged
Check the water level.
The pump stops
Circuit breaker of the engine triggered
Restart after cooling.
The pump starts and stops per-
manently
Light leakage or defective shut-off device
Close the draining pipe to look for the default.
The pump is not tight
Faulty mechanical seal
Change the pump
The three-way valve is not work-
ing anymore
Blocked due to sediments on the valve seat
visual check and, if necessary, dismantle and
clean the valve.
Default indication on the control
panel
The float switch signal sent to the controller is
wrong because the cable is damaged or the float
switch is blocked inside the rainwater storage
tank
Check the contacts or perform a visual control.
Содержание 2551468
Страница 2: ...Fig 1 Fig 3 Fig 2 122 75 Rp 3 4 Rp 1 Rp 1 a b...
Страница 3: ...Fig 4 Fig 5 Fig 6...
Страница 4: ...Fig 11 Fig 7 Fig 9 Fig 10 Fig 8 Max 5 N m Max 5 N m...
Страница 5: ...5 Deutsch 6 English 19 Fran ais 31 Nederlands 44 57 esky 72...
Страница 58: ...el 58 WILO SE 2020 02 1 1 1 2 2 1 2 2...
Страница 59: ...el Wilo RAIN1 59 2 3 2 4 IEC VDE 2 5 IEC VDE 2 6 2 7 2 8 4...
Страница 60: ...el 60 WILO SE 2020 02 3 30 C 60 C 4 Wilo RAIN1 EN1717 5 5 1 Wilo RAIN 1 25 EM Wilo RAIN 1 1 3 premium 2 Q m h...
Страница 65: ...el Wilo RAIN1 65 7 1 7 2 1 7 3 Fig 3 4 Fig 5 Fig 3 12 Fig 6 Fig 7 Fig 8 11 Fig 9 3 8 mm 16 mm...
Страница 66: ...el 66 WILO SE 2020 02 Fig 10 5N m 7 4 60 mm Fig 3 4 8 25 mm Fig 4 16 G3 4 Fig 3 4 4 Fig 3 4 9 Fig 4 5 Fig 4 5 4...
Страница 67: ...el Wilo RAIN1 67 4 G3 4 7 G1 8 G1 7 5 RCD 30 mA RAIN1 0 3 ohm 4...
Страница 68: ...el 68 WILO SE 2020 02 X6 X5 X4 X1 X2 X3 X1 N L1 X2 U V X3 U V X4 NO NC X5 C NO X6 C1 C2 8 Fig 11 6 3 9...
Страница 69: ...el Wilo RAIN1 69 2 7 3 10 9...
Страница 70: ...el 70 WILO SE 2020 02 6 2 6 2 LED Fig 5 24 A01 A11 A21 Wilo A02 A05 Wilo LED 5 ART Wilo 11 Wilo 12...
Страница 71: ...el Wilo RAIN1 71 www wilo recycling com...
Страница 88: ......
Страница 89: ......
Страница 90: ......