through the wall where you are going to install the furnace.  
Before  the  furnace  is  installed,  an  opening  must  be  cut  through 
the wall for the vent. 
 

Find the Studs 

Find  the  studs  where  the  furnace  is  to  be  placed.  Use  a  stud 
locator  or  small  finishing  nails.  Drive  a  nail  on  the  inside  of  the 
first stud. Drive a second nail on the outside of this stud. 

The  inside edge  of  the  next  stud  should  be  about  14-1/2  inches 
from  the  one  found.  Drive  a  finishing  nail  on  the  inside  edge  of 
this stud, then another nail on the outside edge. 
Using  a level,  draw  vertical lines  that  will  represent the  two  stud 
center lines. 
 

Cut Vent Opening 

Line up the center of the stud lines with the center lines you have 
drawn  on  the  wall.  Draw  the  2-1/2  inch  diameter  circle  on  the 
wall. Then mark the location of the gas supply line. 

Using  a  window,  door  or  wall  corner  for  reference,  measure  to 
find where the vent will be on the outside wall. Check to be sure 
of the proper clearances (Figures 1 and 2). If necessary, relocate 
the furnace for proper clearances. 
 

 

 
 

Drill a 1/4 inch hole in the wall at the vent opening center mark all 
the way through to the outside. Cut the 2-1/2 inch diameter hole 
through  the  inside  wall.  Using  the  1/4  inch  hole  as  center,  cut  a 
matching  hole  in  the  outside  wall.  It  may  be  better  to  work  from 
the outside when breaking through brick, stone or tile. 
Make  sure  the  wall  openings  are  aligned  so  vent  tubes  will  fit 
properly. 

In  new  construction,  frame  in  2-1/2  inch  x  2-1/2  inch  opening 
centered between the studs spaced 16 inches on centre and the 
center point located as noted in Figure 3. 

 
Gas and Electrical Supply Openings 

Holes must be drilled for the gas line. Drill a 1-1/2 inch hole in the 
wall for the gas line. You will have to determine whether the gas 
line will enter the home through the outside wall or the floor plate. 
These  instructions  can  only  guide  you  to  where  the  gas  line  will 
enter the furnace. 

The gas line can be run at this time or after the furnace is 
mounted. See "'Gas Supply and Piping" section. 

Rear Panel Mounting (Figure 4-6) 

Set  the  furnace  body  against the  wall  and  mark  the  top  location 
of  the  two  top  corners  of  the  rear  panel  using  masking  or 
painter’s tape. 
 
Move the furnace away from the wall and remove the rear panel. 
Place the rear panel against the wall and mark the vent and gas 
openings.  For  exhaust  tube  only  (standard)  mark  only  the  left 
hole. If using the optional air inlet kit, mark both holes.  
 
 

 

 

FIGURE 3 

FIGURE 4 

Содержание 1753012

Страница 1: ...l switch Do not use any phone or cell phone in your building Extinguish any open flame Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot r...

Страница 2: ...improper installation 4 This warranty does not cover claims which do not involve defective workmanship or materials DUTIES OF THE CONSUMER 1 The heating equipment must be installed by a qualified inst...

Страница 3: ...llation 6 17 Locating Your Wall Furnace 6 Thermostat Installation 9 Cabinet Installation 11 Vent Installation 11 Gas Supply and Piping J 14 Operating Your Furnace 18 20 Operating Instructions 18 Start...

Страница 4: ...pecified 9 BE SURE to provide for adequate combustion and ventilation air The flow of this air to the furnace must not be blocked 10 NEVER vent flue gases into another room a fireplace or any space in...

Страница 5: ...d Hand drill or properly grounded electric drill 6 ft folding rule or tape measure Screwdrivers Phillips Head Pliers wire cutting Stud locator or small finishing nails Tin snips 8 and 12 inch adjustab...

Страница 6: ...lectrical outlet can be brought to the furnace 6 Select a location that will provide adequate accessibility clearance for servicing and proper operation Interior Clearances Figure 2 1 The unit is desi...

Страница 7: ...g center mark all the way through to the outside Cut the 2 1 2 inch diameter hole through the inside wall Using the 1 4 inch hole as center cut a matching hole in the outside wall It may be better to...

Страница 8: ...fter cutting the vent and gas openings place the rear panel back onto the wall and screw into place using the supplied mounting screws The screws should go into the wall studs as there are enough clea...

Страница 9: ...drilling a hole in the wall at the selected location drive a small finishing nail through the ceiling in the comer of the wall and ceiling above the thermostat location Pull the nail out and push a s...

Страница 10: ...3 Push any excess wire back through hole in the wall and plug the hole with insulation to prevent drafts from affecting thermostat operation 4 Being sure to level thermostat for the best appearance F...

Страница 11: ...VC meeting ASTM Standard D1784 For Canada ULC S636 approved duct must be used Use a 45 elbow as the vent termination for the exhaust pipe vent terminations are not counted towards the overall vent len...

Страница 12: ...Installation 12 FIGURE 16 FIGURE 17 FIGURE 18 FIGURE 19...

Страница 13: ...to attach the PVC pipe to the inducer fan and tighten the hose clamps shown in Fig 21 If PVC pipes will be exposed to freezing temperatures the pipes must be insulated using Armaflex or similar insul...

Страница 14: ...burners must not exceed the rated input and pressure shown on the rating plate For natural gas the manifold pressure should be 3 2 inches water column The manifold pressure should be 10 inches water...

Страница 15: ...On L P gas installations use a compound resistant to action of liquefied petroleum gases 3 Use ground joint unions 4 Install a drip leg sediment trap to trap dirt and moisture before it can enter the...

Страница 16: ...cified pressures for testing Higher pressures may damage the gas valve and cause over firing which may result in combustion chamber failure Liquefied petroleum gas L P G is heavier than air and it wil...

Страница 17: ...you have a question regarding the amount of fuel consumed call your local gas utility or gas supplier WARNING DO NOT TAMPER WITH THE REGULATOR OR BURNER ORIFICES AS PROBLEMS RESULTING FROM THERE MAY C...

Страница 18: ...safety information above 2 Make sure there is power to the unit the furnace is supplied with a 3 prong 120VAC power cord The internal switches must be on see fig 31 and 32 3 The furnace has 3 modes of...

Страница 19: ...level The display panel will show the word SET on the top right corner After this sequence the display panel will show heat level 6 Local Mode After setting a desired room temperature on the display...

Страница 20: ...re To measure the input using the gas meter proceed as follows 1 Turn off the gas supply to all other appliances except the furnace 2 With the furnace operating time the smallest dial on the meter for...

Страница 21: ...t panel Using a low profile tray to collect water place underneath the trap and unscrew the bottom of the trap After condensate is collected replace the bottom of the trap replace front panel and rest...

Страница 22: ...er Description Qty 1 6H24 Inner Frame 1 2 6H03 Bottom Support Cover 1 3 6H01 Heat Exchanger Support 1 4 P323702 17 5K Heat Exchanger Asy 1 5 6H13 Blower Housing Support Right 1 6 6H12 Blower Housing D...

Страница 23: ...Replacement Parts List 34 6H31 Front Panel 1 35 P323465 Nylon PCB Standoff 4 36 P323481 Inducer Fan Mounting Screw 4 37 P323459 Fan Motor 1 38 P323460 Blower Wheel 1...

Страница 24: ...24 Page left blank intentionally...

Страница 25: ...Page left blank intentionally...

Страница 26: ...Wiring Diagram 26...

Страница 27: ...eing fastened to an uneven wall Vent tube and air inlet tube may be in a bind with a vent cap assembly Be sure the hole through the wall is correct and parts fit without binding 5 Noisy Blower A Housi...

Страница 28: ...liance Do not touch any electrical switch Do not use any phone or cell phone in your building Extinguish any open flame Immediately call your gas supplier from a neighbor s phone If you cannot reach y...

Отзывы: