Installations in the State of Massachusetts

 

 

22 

b.  Be either hardwired or battery powered or both; and  

c. 

Shall comply with NFPA 720 (2005 Edition). 

3.  A product approved vent terminal must be used, and if applicable, a product approved air intake must be used. Installation shall be 

in  strict  compliance  with  the  manufacturer's  instructions.  A  copy  of  the  installation  instructions  shall  remain  with  the  appliance  or 
equipment at the completion of the installation. 

4.  A  metal  or  plastic  identification  plate  shall  be  mounted  at  the  exterior  of  the  building,  four  feet  directly  above  the  location  of  vent 

terminal.  The  plate  shall  be  of  sufficient  size  to  be  easily  read  from  a  distance  of  eight  feet  away,  and  read  "Gas  Vent  Directly 
Below".

Replacement Parts List 

Reference 
Number 

Item 

Number 

Description 

Qty. 

6H24 

Inner Frame 

6H03 

Bottom Support Cover 

6H01 

Heat Exchanger Support 

P323702  17.5K Heat Exchanger Asy 

6H13 

Blower Housing Support, Right 

6H12 

Blower Housing Deflector 

6H04 

Blowet Housing Assembly 

6H49 

Outer Panel 

6H14 

Air Baffle 

10 

6H02 

Front Heat Shield 

11 

P323458  Inducer Fan 

12 

6H26 

Condensate Trap Support 

13 

P323457  Condensate Trap 

14 

P323452  Gas Valve 

15 

P323483  Valve Bracket Screw 

16 

P323455  Main Coils Connector 

17 

P323456  Modular Solenoid Connector 

18 

P323468  Air Pressure Sensor 

19 

P323467  Wire Harness 

20 

6H29 

Switch Bracket 

21 

P323469  On/Off Switch 

22 

P309600  Hi Limit Switch 

23 

P323450  Control Board 

24 

P323451  Display Panel 

25 

P323461  Touch Screen 

26 

6H30 

Air Filter Guide 

27 

P323470  Air Filter 

28 

P323466  Thermistor Assembly 

29 

6H19 

Air Pan 

30 

P323482  Inducer Fan Mounting Washer 

31 

6H16 

Inlet Pipe Stop 

32 

6H18 

Rear Panel 

33 

6H38 

Exhaust Grill Assembly 

Содержание 1753012

Страница 1: ...l switch Do not use any phone or cell phone in your building Extinguish any open flame Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot r...

Страница 2: ...improper installation 4 This warranty does not cover claims which do not involve defective workmanship or materials DUTIES OF THE CONSUMER 1 The heating equipment must be installed by a qualified inst...

Страница 3: ...llation 6 17 Locating Your Wall Furnace 6 Thermostat Installation 9 Cabinet Installation 11 Vent Installation 11 Gas Supply and Piping J 14 Operating Your Furnace 18 20 Operating Instructions 18 Start...

Страница 4: ...pecified 9 BE SURE to provide for adequate combustion and ventilation air The flow of this air to the furnace must not be blocked 10 NEVER vent flue gases into another room a fireplace or any space in...

Страница 5: ...d Hand drill or properly grounded electric drill 6 ft folding rule or tape measure Screwdrivers Phillips Head Pliers wire cutting Stud locator or small finishing nails Tin snips 8 and 12 inch adjustab...

Страница 6: ...lectrical outlet can be brought to the furnace 6 Select a location that will provide adequate accessibility clearance for servicing and proper operation Interior Clearances Figure 2 1 The unit is desi...

Страница 7: ...g center mark all the way through to the outside Cut the 2 1 2 inch diameter hole through the inside wall Using the 1 4 inch hole as center cut a matching hole in the outside wall It may be better to...

Страница 8: ...fter cutting the vent and gas openings place the rear panel back onto the wall and screw into place using the supplied mounting screws The screws should go into the wall studs as there are enough clea...

Страница 9: ...drilling a hole in the wall at the selected location drive a small finishing nail through the ceiling in the comer of the wall and ceiling above the thermostat location Pull the nail out and push a s...

Страница 10: ...3 Push any excess wire back through hole in the wall and plug the hole with insulation to prevent drafts from affecting thermostat operation 4 Being sure to level thermostat for the best appearance F...

Страница 11: ...VC meeting ASTM Standard D1784 For Canada ULC S636 approved duct must be used Use a 45 elbow as the vent termination for the exhaust pipe vent terminations are not counted towards the overall vent len...

Страница 12: ...Installation 12 FIGURE 16 FIGURE 17 FIGURE 18 FIGURE 19...

Страница 13: ...to attach the PVC pipe to the inducer fan and tighten the hose clamps shown in Fig 21 If PVC pipes will be exposed to freezing temperatures the pipes must be insulated using Armaflex or similar insul...

Страница 14: ...burners must not exceed the rated input and pressure shown on the rating plate For natural gas the manifold pressure should be 3 2 inches water column The manifold pressure should be 10 inches water...

Страница 15: ...On L P gas installations use a compound resistant to action of liquefied petroleum gases 3 Use ground joint unions 4 Install a drip leg sediment trap to trap dirt and moisture before it can enter the...

Страница 16: ...cified pressures for testing Higher pressures may damage the gas valve and cause over firing which may result in combustion chamber failure Liquefied petroleum gas L P G is heavier than air and it wil...

Страница 17: ...you have a question regarding the amount of fuel consumed call your local gas utility or gas supplier WARNING DO NOT TAMPER WITH THE REGULATOR OR BURNER ORIFICES AS PROBLEMS RESULTING FROM THERE MAY C...

Страница 18: ...safety information above 2 Make sure there is power to the unit the furnace is supplied with a 3 prong 120VAC power cord The internal switches must be on see fig 31 and 32 3 The furnace has 3 modes of...

Страница 19: ...level The display panel will show the word SET on the top right corner After this sequence the display panel will show heat level 6 Local Mode After setting a desired room temperature on the display...

Страница 20: ...re To measure the input using the gas meter proceed as follows 1 Turn off the gas supply to all other appliances except the furnace 2 With the furnace operating time the smallest dial on the meter for...

Страница 21: ...t panel Using a low profile tray to collect water place underneath the trap and unscrew the bottom of the trap After condensate is collected replace the bottom of the trap replace front panel and rest...

Страница 22: ...er Description Qty 1 6H24 Inner Frame 1 2 6H03 Bottom Support Cover 1 3 6H01 Heat Exchanger Support 1 4 P323702 17 5K Heat Exchanger Asy 1 5 6H13 Blower Housing Support Right 1 6 6H12 Blower Housing D...

Страница 23: ...Replacement Parts List 34 6H31 Front Panel 1 35 P323465 Nylon PCB Standoff 4 36 P323481 Inducer Fan Mounting Screw 4 37 P323459 Fan Motor 1 38 P323460 Blower Wheel 1...

Страница 24: ...24 Page left blank intentionally...

Страница 25: ...Page left blank intentionally...

Страница 26: ...Wiring Diagram 26...

Страница 27: ...eing fastened to an uneven wall Vent tube and air inlet tube may be in a bind with a vent cap assembly Be sure the hole through the wall is correct and parts fit without binding 5 Noisy Blower A Housi...

Страница 28: ...liance Do not touch any electrical switch Do not use any phone or cell phone in your building Extinguish any open flame Immediately call your gas supplier from a neighbor s phone If you cannot reach y...

Отзывы: