Power Connection for U.S. Application
Connect the TFP 010 power supply to the 3-pin Molex™ connector located on the
rear of the TX90 (see Figure 8).
For Applications Outside the U.S. Requiring 240 VAC Mains Supply:
Use the transformer power supply, model TFP 027. Make sure
TFP 027 power input switch (located on bottom of power supply)
is set to the “230” position.
Secondary specifications: 24 VAC, 35 VA, 50/60 Hz.
Plug the power supply into the AC outlet.
TFP 027-01: 230VAC, Euro Mains Plug
TFP 027-02: 230VAC, UK Mains Plug
NOTE:
The WIR TX90 transmits when a baseband signal is present, and will shut off immediately
when no baseband signal is present. This auto shut-off feature preserves the life of the
infrared LEDs and reduces power consumption.
This system is designed for class 2, low-voltage wiring.
Always follow local electrical codes when doing low voltage wiring.
u
Connect Power
WARNING: POWERLINE VOLTAGE MUST NOT FALL BELOW 90V, 0R
SYSTEM PERFORMANCE WILL BE GREATLY REDUCED!
Figure 7: WIR TX90 Rear View
Power Connection
Plug in Power Supply 120
VAC (US): TFP 010
230 VAC (CE): TFP 027
Wall/Ceiling
Mounting Bracket (BKT 024)
Set of threaded holes for use with
mounting bracket
Baseband Out
BNC Connector, 50 Ω
50 kHz-8 MHz Baseband
Power In Jack
Figure 8
Содержание SoundPlus WIR SYS 90 ADV
Страница 16: ...16 2011 Williams Sound MAN 119G...