8
© Wilks-USA
TX750 / TX750i
Pull the trigger to eliminate
trapped air and wait for a steady
flow of water to emerge from the
spray nozzle.
NOTE: In order to assist further
setup it is recommended to press
the trigger during the pulling of
recoil start handle.
Fig.15
To prevent accidental operation
the trigger is fitted with a locking
facility.
Fig.16
Starting the Engine (fig.17-20):
Push the fuel lever A to the right
(ON position)
Fig.17
Fig.18
Fig.19
Push the Choke lever B to the left;
closing the Choke for initial start-
up.
NOTE:
Do not use the Choke
if the engine or air temperature is
warm.
Turn the engine switch clockwise
to the ON Position.
•
Connect a water supply hose (not supplied) to the water inlet connection of the pressure washer
•
Turn on the water supply and pull the trigger until water is continually flowing out of the nozzle.
WATER SUPPLY FROM A CONTAINER / STANDING WATER
•
Unscrew the coupling part for the water inlet.
•
Screw the suction hose with filter (not Included) onto the water connection of the unit.
•
Hang the filter in the container.
•
Vent the unit before operation.
•
Unscrew the high pressure line at the high pressure outlet of unit.
•
Switch on the unit and let it run until water is free of bubbles at the high pressure outlet.
•
Switch off the unit and screw on high pressure hose again.
Water Supply from the Water Mains