INSTALLATION TYPE B
These diagrams detail the installaon of the appliance into a Pre Cast Flue block and
a
950L STANDARD MANTEL
is being fiPed.
For details on 950L STANDARD MANTEL crical dimensions see page 8
Ensure the hearth is set level before con2nuing with the
installa2on. Failure to install a level hearth could affect the
installa2on of the mantel and appliance.
The
900 PRECAST SPACER KIT
is used to create an
interface between the precast flue and the
900
FIXING PLATE
.
Temporarily fit the hearth
and
firmly aPach the FIXING PLATE to the wall. See
further details on page 12.
Using mortar or fondue around the inside edge of
the SPACER/FLUE should be sealed and fixed into
place as if it were a marble back panel. It is
important that no leakage should occur.
Now remove the hearth carefully to avoid
damage whilst the stud work proceeds.
Timber studding is acceptable providing a 25mm
gap is le around the
900 PRECAST SPACER
.
Plasterboard the area thus creang a thin false
chimney breast.
The
front face
of
the
plasterboard should be around 2-3mm rearward
of the front face of the
900 PRECAST SPACER
.
Once the area is skimmed with plaster the surface
should be level. For clarity the total thickness of
the false chimney breast should be the same as
the spacer thickness, i.e 55mm.
For minimum hearth requirements see page 8.
The
950L FIXING PLATE
is then screwed to the
950L PRECAST SPACER
using the screws provided, then using fire
cement or similar around the inside edge of the joint between the
950L FIXING PLATE
and the
950L PRECAST
SPACER
. Furthermore a suitable high temperature masc should be used to further seal around the outside edge of
the
950L FIXING PLATE
and the
SPACER. See further details on page 13.
It is extremely important that both the
950L
PRECAST SPACER
and the
950L FIXING PLATE
are
sealed to the flue as essenally a complete
fireplace opening. Check the integrity of the
spacer and fixing plate installaon before
proceeding.
The TYPE B INSTALLATION is completed by
installing the
950L STANDARD
MANTEL
to the
wall securely. The mantel should be centred
around the
950L FIXING PLATE
.
The crical dimensions of the
950L STANDARD
MANTEL
are detailed on page 8. These crical
dimensions ensure that the front trim plate of the
fire and the front face of the mantel are aligned.
The front trim plate of the appliance is fully
adjustable with four independent magnets. These
magnets can be screwed in or out to posion the
front trim plate correctly. This adjustment is
provided as there may be some variaon in the
wall flatness and level.
See page 17 for full details regarding front trim installaon and adjustment.