21
The following procedures can and should
only
be performed by a
GAS SAFE registered installer
.
This appliance should be serviced annually by a
GAS SAFE
registered installer.
Removal / Replacement of Gas Carrying Components.
The removal and replacement of all the gas carrying components will require the removal of the burner tray. The
following informaon details the removal of this tray. Once removed, refer to the relevant secon that follows detailing
the removal of the specific component (s).
Remove the marble access cover and the front trim from the appliance.
Turn off the gas supply at the isolaon valve on the appliance. Ensure the appliance is cold.
Remove the glass panel (as described on page 17)
Remove the fuel effect components - put in a suitable locaon where they cannot be damaged.
Disconnect the gas supply from the restrictor elbow.
Remove the seven (7) screws (shown below) securing the burner tray to the firebox as detailed in the diagram.
SERVICING THE APPLIANCE
Now carefully pull the burner tray from the fire box. The burner tray can now be serviced or repaired
accordingly—see the following pages for informaon about removing and replacing serviceable components.
Important Note:
Check the ceramic gasket located around the edge of the firebox where the burner tray was
seated. Ensure this gasket is in good condion prior to reinstallaon. If damaged, this gasket should be replaced.
See page 28 for part no. manufacturer’s details.
Re-assemble the tray in the reverse order.