![Wilden Turbo-Flo T8 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/wilden/turbo-flo-t8/turbo-flo-t8_engineering-operation-and-maintenance_980906011.webp)
WIL-10272-E-01
Wilden
®
11
PERFORMANCE
T8 METAL
STALLION TPE -FITTED
Height ............................ 668 mm (26.3")
Width ............................. 610 mm (24.0")
Depth ............................. 345 mm (13.6")
Est. Ship Weight ..... Aluminum 33 kg (72 lbs)
Cast Iron 52 kg (114 lbs)
316 Stainless Steel 48 kg (106 lbs.)
Air Inlet.................................. 19 mm (3/4")
Inlet ....................................... 51 mm (2")
Outlet ...................................... 51 mm (2")
Suction Lift ........................ 2.1 m Dry (7')
9.5 m Wet (28')
Disp. Per Stroke
1
................. 1.89 l (0.50 gal.)
Max. Flow Rate .......... 606 lpm (160 gpm)
Max. Size Solids ................. 19.0 mm (1/4")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2 bar (30 psig) head pressure.
Example:
To pump 322 lpm (85 gpm)
against a discharge pressure head of
2.1 bar (30 psig) requires 4.1 bar (60 psig)
and 94 Nm
3
/h (55 scfm) air consumption.
(See dot on chart.)
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump performance curve.
Содержание Turbo-Flo T8
Страница 1: ...EOM ENGINEERING OPERATION MAINTENANCE T8 Clamped Metal Pump WIL 10272 E 01 Where InnovationFlows...
Страница 23: ...WIL 10272 E 01 Wilden 23 EXPLODED VIEW AND PARTS LISTING T8 METAL Rubber TPE Fitted EXPLODED VIEW Section 9...
Страница 25: ...WIL 10272 E 01 Wilden 25 T8 METAL Rubber TPE Fitted EXPLODED VIEW...
Страница 27: ...WIL 10272 E 01 Wilden 27 T8 METAL PTFE Fitted EXPLODED VIEW...
Страница 30: ...WIL 10272 E 01 Wilden Notes...
Страница 31: ...WIL 10272 E 01 Wilden Notes...