P2 Clamped Plastic
Step 4
Step 5
Step 6
Remove the top liquid retainer and
retainer O-rings, discharge valve balls,
seats and valve seat O-rings from the
liquid chamber and inspect for nicks,
gouges, chemical attack or abrasive
wear.
Using a 1/2" socket driver, loosen the
bottom retainers.
NOTE:
Inverting the pump will facilitate
removal of inlet manifold.
Remove the bottom liquid retainer and
retainer O-rings, discharge valve balls,
seats and valve seat O-rings from the
liquid chamber and inspect for nicks,
gouges, chemical attack or abrasive wear.
Step 7
Step 8
Step 9
With a 1/2" box wrench, loosen the large
clamp bands that secure the liquid
chambers to the center section.
Rotate the clamp bands so that they can
be removed.
After clamp bands are removed, pull
liquid chambers apart.