8 Solar fluid

  

 
8.1 Product information Solarliquid ready for use (WIK-PE20) 
 

Environmentally  friendly,  ready-to-use  long-term  antifreeze  with  corrosion  inhibitors  especially  for  flat  plate  and 
vacuum tube collectors with a high thermal load (up to 260 °C). 
 
Product data: 

Appearance:    

 

 

 

clear, amber liquid 

Base:  

 

 

 

 

 

superior glycol 

Flashpoint (°C):  

 

 

 

> 100 (ASTM D 51758) 

Boiling point (°C):    

 

 

> 102 (ASTM D 1120) 

Density (20 °C):  

 

 

 

1.02 – 1.04 g/cm³ (DIN 51757) 

Antifreeze (crystallization point):   approx. -23 °C 
Antifreeze (solidification point):  

approx. -29 °C 

pH value (20 °C):    

 

 

7.5 – 8.5 (ASTM D 1287) 

Viscosity (20 °C):    

 

 

approx. 15.0 mm²/s 

 
 

Product properties: 
 
SOLARLIQUID  HT  ready  for  use 

is  an  odorless  liquid  that  is  used  as  antifreeze  or  heat  transfer  fluid  for  thermal  solar 

installations (flat plate and vacuum tube collectors) with a high thermal load. The special corrosion inhibitors protect the metal 
and  plastic  materials  commonly  used  in  construction,  including  aluminium,  against  corrosion  and  deposits.  The  sealing 
materials commonly used in heating installations are not affeced by Solarliquid HT ready for use. 
 

SOLARLIQUID HT ready for use 

 

cannot be mixed with any other type of antifreeze  

 

is inhibited nitrite-, amine- and phosphate-free  

 

is biodegradable 

According to the German Ordinance on Hazardous Substances, no specific labeling is required for Solarliquid L concentrate 
ready for use and HT ready for use (see safety data sheet).  

 
General information: 

 
The  systems  must  conform  to  DIN  standard  4757,  part  1,  and  be  implemented  as  a  closed  system,  since  there  must  be  no 
atmospheric oxygen in the system. It must be ensured that the circulating pump is suitable for operation with antifreeze agents. 
Before  being  filled,  the  system  should  be  flushed  with  water  and  the  tightness  of  all  connections  checked  through  pressure 
testing. The system must be free of impurities and free of other liquids. There must be no deposits on the metal surfaces. After 
pressure  testing,  the  system  must  immediately  be  filled  with  Solarliquid  HT  ready  for  use.  Do  not  allow  any  air  to  enter! 
Galvanized system components should be avoided since zinc is not resistant to glycols. In the case of leakage, only top up with 
the same product, never utilize different solar liquids in the same system. In our experience, Solarliquid HT ready for use can 
be stored or used for several years. Nonetheless, the concentration (frost resistance) should be checked annually. In the case 
of a loss of liquid, never top up with water.  

Use only Solarliquid HT ready for use for topping up! 

 

 
Recommendation for use: 

The  optimum  temperature  for  use  is  between  -23  °C  and  230  °C.  For  prolonged  temperatures  of  more  than  230  °C  we 
recommend installing adequately large expansion tanks so that the heat transfer fluid can flow out of the collectors. 
 

Method of testing corrosion properties: 

We recommend that the solar fluid with which the system is filled be checked regularly (roughly annually). With the pH value 
you can test the corrosion properties of our solar fluid. The pH value should be > 7.5. This is measured using pH test strips. If 
the value is lower than this, the solar fluid should be replaced. 
 
 

Method of testing frost protection: 

 

Krüss device 

Refractometer 

Frost 
protection 

Brix 

RI 

MEG scale 

MPG scale 

-8 °C

 

22.3

 

1.3676

 

-17 °C

 

-13 °C

 

-15 °C

 

29.6

 

1.3807

 

-29 °C

 

-22 °C

 

-23 °C

 

35.7

 

1.3915

 

-46 °C

 

-35 °C

 

Содержание Wikosun 2010

Страница 1: ...e covered if the installation instructions are followed Warranty does not cover any damages caused by non observance of this manual The correct functioning is only guaranteed if the installation instr...

Страница 2: ...Wikosun 2010 2510 Profile rails aluminum Z clamp Collector support bracket Parallel compression fitting 18mm Compression X fitting 18x18x12 x3 4 FD incl air screw and sensor pocket Insulation on site...

Страница 3: ...6 washers ST BFS BL 2 clamps for rolled steel joist 2 screws M8 2 nuts M8 ST BFS ST 2 stair bolts M10 2 ears 6 nuts 2 seals ST BFS T 2 roof hooks profiled sheeting ST BFS W 2 roof hooks corrugated sh...

Страница 4: ...s 5 mm 1 Flat section aluminum 40x5 mm l 1710 mm s 5 mm 7 Hex head screws stainless steel M8 x 20 mm 7 Hex nuts stainless steel M8 7 Lock washers M8 Chart 4 Fastening sets flat roof mounting horizont...

Страница 5: ...with reference to DIN 1055 100 DIN 1055 4 and DIN 1055 5 Determine the values of local snow loads according to country specific data Determine the values of local wind loads according to country speci...

Страница 6: ...mensionally mediated according to the number of collectors The distances between the upper and lower profile rail are as follows see fig 4 On roof mounting vertical 1500 1600 mm WIKOSUN 2010 1800 1900...

Страница 7: ...ms Smaller rafters should be doubled or trebled in width at the point where brackets are to be fixed to them see fig 6 If a foil under the roof tiles exist and is harmed during installation the openin...

Страница 8: ...al installation 0 5m 200 kg 300 kg 5 10 m 250 kg 350 kg 10 20 m 300 kg 400 kg 20 m Calculation necessary Chart 8 Loading per collector 3 3 1 1 Installation of the mounting frame on mass elements e g c...

Страница 9: ...ulated and measured For roof angles smaller than 60 the vertical angle section must be cut 25mm above the hole Install the base of the frame the cross bars and the back bars and connect the angle sect...

Страница 10: ...Position the collectors and fix them carefully The collectors are connected with each other by using the corresponding parallel compression fittings Hand tighten the bolts and protect the connecting...

Страница 11: ...shions 3 9 Hydraulic pressure test After a successful installation rinse the entire collector circulation with water Before commissioning the collector circulation must be checked with a water pressur...

Страница 12: ...450 25 18 9 540 40 22 10 5 630 40 22 12 720 50 22 13 5 810 50 28 15 900 80 Valid for parallel collector connection In the case of series connection of the same collector arrays the flow rate is halve...

Страница 13: ...ool Absorber Material Aluminium plate on copper Aluminium plate on copper Absorber coating TINOX ENERGY Alanod Mirotherm TINOX ENERGY Alanod Mirotherm Pressure loss 50 l h 49 Pa collector 54 Pa collec...

Страница 14: ...minated Switch on again your solar heating system Please never vent at sunshine or running pump Please do not undertake an additional venting process If the system s working pressure drops later on or...

Страница 15: ...no atmospheric oxygen in the system It must be ensured that the circulating pump is suitable for operation with antifreeze agents Before being filled the system should be flushed with water and the ti...

Страница 16: ...he local authority in charge Cleaning clean with liquid binding material sand kieselguhr acid binder or universal binder Recycle contaminated material separately Keep the concentrate in a cool and dry...

Страница 17: ...hidden defects immediately after emerging In case of hidden defects it is only valid for the warranty exceeding the legal warranty period if the collectors are changed or maintained by non spezialise...

Страница 18: ...ick vent valve at collectors Primary pressure exp vessel C Type Cooling function from colour unchanged brown black cloudy Flow rate m System settings Controller setting Consumer 1 e g DHW Consumer 2 e...

Страница 19: ...ollector fastening is stable User has been instructed Maintenance contract Operation of pumps checked Temperature sensores indicate realistic values Collector interior is not fogged Collector is clean...

Отзывы: