4 Technical data
Type
GS 117 E GS 152 E GS 192 E
Capacity
[liter]
ca. 115
ca. 150
ca. 190
Max. working pressure
[bar]
10
10
10
Output
[kW]
7,12
8,12
9,18
Input (gross)
[kW]
8,0
9,1
10,2
Flue gas temperature
[°C]
155
171
171
Flue gas volume
[kg/h]
18,3
19,7
21,5
Flue draft requirement
[mbar]
0,04
0,04
0,04
CO
2
by volume
[%]
6,4
6,8
7,0
Time to recover from 10°C to 60°C
[ca. min]
52
61
67
Energy loss
[kWh/24h]
4,08
4,85
5,04
Continuous output DHW of 45°C
[l/h]
175
200
226
Hot water starting efficiency
[ca. l/10 min]
160
205
266
Gas consumption
Natural gas group E H
uB
9,4 kWh/m
3
[m
3
/h]
0,85
0,97
1,09
Natural gas group LL H
uB
8,5 kWh/m
3
[m
3
/h]
0,94
1,07
1,20
Liquid gas (propane) H
uB
12,8 kWh/kg
[kg/h]
0,63
0,71
0,8
Nominal Load N
L
(70°)
ca. 1,7
ca. 2,7
ca. 3,4
Weight (empty)
[kg]
ca. 65
ca. 80
ca. 90
Chart 3
Necessary flow pressure for gas connection
Natural gas
18 mbar – 25 mbar
Liquid gas
50 mbar +/- 5 mbar
If the flow pressure for gas connection is outside those values, an installation is prohibited (see 6.1, 3 ff)
Gas (at 15°C, 1013 mbar)
according to CE-Norm
according to DVGW
E (G20)
Wobbeindex: 11,3 – 15,2 kWh/m³
N (H)
Wobbeindex: 12,0 – 15,7 kWh/m³
LL (G25)
Wobbeindex: 9,5 – 12,4 kWh/m³
N (L)
Wobbeindex: 10,5 – 13,0 kWh/m³
P (G31)
Wobbeindex: 20,3 – 21,3 kWh/m³
F