background image

© Wikora GmbH 

Page 3  

As of November 2013 

 

 

Errors excepted. 

3  Dimensions and connections 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
                                                                                                                                                                                        

Illustration1 

1    Hot water connection R 3/4 
2    Cold water connection R 3/4 
3    Gas connection Rp 1/2 
4    Flow operated safety device 
5    Anode 
6    Baffle plate 
7    Water tank 
8    Circulation immersion pipe R ¾ (Accessory) 
9

  

  Insulation 

10  Casing 
11  Control fittings 
12  Main burner 
13  Pilot burner 
15  Cover plate 
17  Drain 
20  Temperature control button 
22  Piezo spark ignition 

a     Diaphragm - safety valve min. DN 15 
b     Drain pipe 
c     Water stop valve

 

d     Manometer- connection nozzle

 

e     Backflow preventer

 

f      Pressure reducing valve if more than 8 bar connection pressure 
g     Water stop valve

 

 

h     Test valve 
i      Gas stop valve 
k     Circulation pump 

 

Dimensions: 

 

Type 

H1 

Height 

gas connection 

Diameter tube 

flue gas 

 

[mm] 

[mm] 

[mm] 

[mm] 

[mm]  [mm]  [mm] 

[mm] 

[mm] 

[mm] 

GS 117 E 

480 

480 

224 

1140 

1140  1140  1208 

1100 

303 

80 

GS 152 E 

480 

480 

224 

1396 

1396  1396  1464 

1356 

303 

80 

GS 192 E 

480 

480 

224 

1713 

1713  1713  1781 

1673 

303 

80 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    Chart 1

 

Connections: 

 

Type 

GS 117 E 

GS 152 E 

 GS 192 E 

Cold water / hot water 

1/2 

¾ 

¾ 

¾ 

Circulation 

¾ 

¾ 

¾ 

Drain 

17 

Rp 

½ 

½ 

½ 

Gas connection 

18 

Rp 

½ 

½ 

½ 

Anode 

19 

Rp 

¾ 

¾ 

¾ 

 

Chart 2 

      

R     =    male thread                     

   

 

 

 

 

 

 

 

 

 

 

 

 

 

Rp  =   female thread 

 

 

 

Содержание GS 117 E

Страница 1: ...ber who observes the local norms and regulations The installation and maintenance record must be entirely completed and the user has to be instructed accordingly Efficient operation can only be guaran...

Страница 2: ...uit The tank is protected against corrosion by double coated enamel and magnesium anode An insulation layer between the internal tank and the steel plate housing minimizes loss of heat The steel plate...

Страница 3: ...DN 15 b Drain pipe c Water stop valve d Manometer connection nozzle e Backflow preventer f Pressure reducing valve if more than 8 bar connection pressure g Water stop valve h Test valve i Gas stop va...

Страница 4: ...min 160 205 266 Gas consumption Natural gas group E HuB 9 4 kWh m3 m3 h 0 85 0 97 1 09 Natural gas group LL HuB 8 5 kWh m3 m3 h 0 94 1 07 1 20 Liquid gas propane HuB 12 8 kWh kg kg h 0 63 0 71 0 8 No...

Страница 5: ...circulation pipe must be fitted at the tank only with an original connection attachment available as spare parts at the connection point Connect the circulation pump and reverse flow stopcock between...

Страница 6: ...d cuts off the gas supply automatically After a period of 5 minutes switch the gas boiler can be put again into operation see commissioning No 6ff Should the appliance cut off several times via the fl...

Страница 7: ...in the tank The appliance is working automatically The gas control fittings will switch off or on the main burner depending on the water temperature At the moment the appliance is switched on again th...

Страница 8: ...he measure nozzle 30 gas tight 6 Remove screw of the measure nozzle 21 and connect U tube manometer 7 Open gas stop cock and put appliance into operation according to Commissioning page 7 8 Check that...

Страница 9: ...ypes Any conversion is only to be undertaken by a registered specialist 8 1 From natural gas to liquid gas 8 1 1 Close gas stop cock and remove cover plate 15 8 1 2 Remove burner unit Loosen screws fo...

Страница 10: ...l min at nominal load Gas volume l min at nominal load kWh m Natural gas group LL 8 5 15 5 17 6 19 8 Natural gas group E 9 4 14 1 16 1 18 0 Liquid gas propane 27 7 4 8 5 4 6 1 Net heating value HUB at...

Страница 11: ...ormed of the importance of regular maintenance and that this is a decisive factor as to how long the appliance will last Openings necessary to allow air circulation around the site of installation mus...

Страница 12: ...ked I Check gas supply adjust dimensions of gas pipes clean connecting pipes clean dirt filter Ignition nozzle blocked I Clean ignition nozzle The installed ignition nozzle is too small I Install corr...

Страница 13: ...e has been modified through the installation of externally supplied parts or through irregular professional maintenance Subject to our general terms and conditions Legal warranty 2 years Guarantee yea...

Страница 14: ...aller Signature Signature Place of installation Name ZIP Code Place Street Phone Tank model Serial number Date of invoice Anode maintenance record Date Visual examination of anode Exchange of anode Si...

Отзывы: