4.  Transport, packaging and storage

4.1  Transport

Check the instrument for any damage that may have been caused by transport.

Obvious damage must be reported immediately.

CAUTION!

Damage through improper transport

With improper transport, a high level of damage to property can occur.

▶ 

When unloading packed goods upon delivery as well as during internal 

transport, proceed carefully and observe the symbols on the packaging.

▶ 

With internal transport, observe the instructions in chapter 4.2 “Packaging 

and storage”.

If the instrument is transported from a cold into a warm environment, the formation of 

condensation may result in instrument malfunction. Before putting it back into operation, 

wait for the instrument temperature and the room temperature to equalise.

4.2  Packaging and storage

Do not remove packaging until just before mounting.

Keep the packaging as it will provide optimum protection during transport (e.g. change 

in installation site, sending for repair).

Permissible conditions at the place of storage:

■ 

Storage temperature: -20 ... +70 °C (-4 ... +176 °F)

■ 

Humidity: 35 ... 85 % relative humidity (no condensation)

Avoid exposure to the following factors:

■ 

Direct sunlight or proximity to hot objects

■ 

Mechanical vibration, mechanical shock (putting it down hard)

■ 

Soot, vapour, dust and corrosive gases

■ 

Hazardous environments, flammable atmospheres

Store the instrument in its original packaging in a location that fulfils the conditions listed 

above.

5.  Commissioning, operation

Before installation, commissioning and operation, ensure that the appropriate instru-

ment has been selected in terms of design and specific measuring conditions.
Tools: Cross-head screwdriver, open-ended spanner 36 mm, 7 mm, 5.5 mm.

5.1  Requirements at the measuring point

■ 

The process pressure and flow must not exceed the specified maximum operating 

pressure and flow.

■ 

Permissible ambient and medium temperatures remain within the performance limits.

■ 

Protected from weather influences.

■ 

Protected from drop

■ 

The instrument must not be subjected to any external loading (e.g. use as a climbing 

aid, support for objects).

■ 

Sealing faces are clean and undamaged.

■ 

Sufficient space for a safe electrical installation.

→ 

For performance limits see chapter 9 “Specifications”

5.2  During commissioning

■ 

After unpacking the instrument, a visual inspection for damage must be carried out.

■ 

Suitable paddle is selected according to the line size and tightened to the paddle 

arm by screws and nylock nut (Approx. 0.6 Nm).

■ 

Paddles should be assembled starting from smaller paddle followed by larger, while 

using multiple paddles.

■ 

Ensure that paddle is free to move inside the pipe and does not rub the sides.

Paddles assembly

1.  Withdrawal of paddle 

adjoining screws

2.   Tightening paddles

Front view

Back view

Содержание FSM-6100

Страница 1: ...mo CR Italy Tel 39 0372 6404 Fax 39 0372 640490 salesflow it wika com www wika com Flow switch For industrial heat exchangers Model FSM 6100 Contents 1 General information 2 Design and function 3 Safe...

Страница 2: ...all apply Subject to technical modifications Further information Internet address www wika com Relevant data sheet FV 30 10 Abbreviations definitions SPDT Single pole double throw NC Normally closed c...

Страница 3: ...contrary to the intended use 3 3 Improper use WARNING Injuries through improper use Improper use of the instrument can lead to hazardous situations and injuries Refrain from unauthorised modification...

Страница 4: ...ting it down hard Soot vapour dust and corrosive gases Hazardous environments flammable atmospheres Store the instrument in its original packaging in a location that fulfils the conditions listed abov...

Страница 5: ...ectrical mounting The connection cable must provide basic insulation for external circuits of protection class I The instrument must be able to be switched off completely by means of a switch or a con...

Страница 6: ...ken out of operation immediately Ensure that there is no pressure in the instrument and that the load circuit is switched off Protect against being put into operation accidentally Contact the manufact...

Страница 7: ...dismounted instrument in order to protect persons and the environment from exposure to residual media 8 Dismounting return and disposal WARNING Physical injuries and damage to property and the enviro...

Страница 8: ...le combinations ON falling flow LPM ON rising flow LPM Maximum operating flow LPM in mm L mm Mini mum Maxi mum Mini mum Maxi mum 1 25 28 15 50 25 60 150 1 25 32 28 45 100 50 110 150 1 5 40 28 50 140 6...

Отзывы: