background image

3

WIKA operating instructions, flow switch, model FSM-6100

83790004.00 12/2020 EN

3.  Safety

3.1  Explanation of symbols

WARNING!

... indicates a potentially dangerous situation that can result in serious injury or 

death, if not avoided.

CAUTION!

... indicates a potentially dangerous situation that can result in light injuries or 

damage to property or the environment, if not avoided.

DANGER!

... identifies hazards caused by electrical power. Should the safety instructions 

not be observed, there is a risk of serious or fatal injury.

WARNING!

... indicates a potentially dangerous situation that can result in burns, caused 

by hot surfaces or liquids, if not avoided.

Information

... points out useful tips, recommendations and information for efficient and 

trouble-free operation. 

3.2  Intended use

The model FSM-6100 mechanical flow switch is fitted with an SPDT switch contact 

and is used in control, monitoring and alarm applications. The switch point can be 

specified by the customer on site. The instrument can switch electrical loads of up to 

AC 230 V, 15A).  

The FSM-6100 flow switch offers many application possibilities for 

Water, ethylene glycol, any other liquid non corrosive to brass, Phosphor bronze and 

Nitrile material. 

WARNING!

Use in the wrong application can lead to considerable personal injury and 

damage to equipment.

▶ 

Only use the instrument in applications that lie within its technical perfor-

mance limits (e.g. max. ambient temperature, material compatibility, ...). 

For performance limits see chapter 9 “Specifications”.

▶ 

This instrument is not permitted to be used in hazardous areas!

The instrument has been designed and built solely for the intended use described here, 

and may only be used accordingly.
The manufacturer shall not be liable for claims of any type based on operation contrary 

to the intended use.

3.3  Improper use

WARNING!

Injuries through improper use

Improper use of the instrument can lead to hazardous situations and injuries.

▶ 

Refrain from unauthorised modifications to the instrument.

▶ 

Do not use the instrument within hazardous areas.

▶ 

Do not use the instrument with abrasive or corrosive media.

Any use beyond or different to the intended use is considered as improper use.

3.4  Personnel qualification

WARNING!

Risk of injury should qualification be insufficient!

Improper handling can result in considerable injury and damage to equipment.

▶ 

The activities described in these operating instructions may only be carried 

out by skilled personnel who have the qualifications described below.

Skilled electrical personnel

Skilled electrical personnel are understood to be personnel who, based on their 

technical training, know-how and experience as well as their knowledge of country-

specific regulations, current standards and directives, are capable of carrying out work 

on electrical systems and independently recognising and avoiding potential hazards. 

The skilled electrical personnel have been specifically trained for the work environment 

they are working in and know the relevant standards and regulations. The skilled 

electrical personnel must comply with current legal accident prevention regulations.

3.5  Labelling, safety marks

 

Product label (example)

Before mounting and commissioning the instrument, ensure you read the 

operating instructions!

j

  Model number

k

 Approvals

l

  Article number

m

  Serial number 

n

  Operating pressure

o

  Ambient temperature

p

  Medium temperature 

q

  Electrical rating

r

  Coded date of manufacture

s

  Ingress protection 

FLOW SWITCH

Euromisure Sas di WIKA Italia Srl,

Via G.Borghisani 4, 26035 Pieve S.Giacomo (CR) Italy. www.wika.com

Ambient temperature

Medium temperature

Electrical rating

Coded date of manufacture

Ingress protection

Model number

Approvals

Article number

Serial number

Operating pressure



Содержание FSM-6100

Страница 1: ...mo CR Italy Tel 39 0372 6404 Fax 39 0372 640490 salesflow it wika com www wika com Flow switch For industrial heat exchangers Model FSM 6100 Contents 1 General information 2 Design and function 3 Safe...

Страница 2: ...all apply Subject to technical modifications Further information Internet address www wika com Relevant data sheet FV 30 10 Abbreviations definitions SPDT Single pole double throw NC Normally closed c...

Страница 3: ...contrary to the intended use 3 3 Improper use WARNING Injuries through improper use Improper use of the instrument can lead to hazardous situations and injuries Refrain from unauthorised modification...

Страница 4: ...ting it down hard Soot vapour dust and corrosive gases Hazardous environments flammable atmospheres Store the instrument in its original packaging in a location that fulfils the conditions listed abov...

Страница 5: ...ectrical mounting The connection cable must provide basic insulation for external circuits of protection class I The instrument must be able to be switched off completely by means of a switch or a con...

Страница 6: ...ken out of operation immediately Ensure that there is no pressure in the instrument and that the load circuit is switched off Protect against being put into operation accidentally Contact the manufact...

Страница 7: ...dismounted instrument in order to protect persons and the environment from exposure to residual media 8 Dismounting return and disposal WARNING Physical injuries and damage to property and the enviro...

Страница 8: ...le combinations ON falling flow LPM ON rising flow LPM Maximum operating flow LPM in mm L mm Mini mum Maxi mum Mini mum Maxi mum 1 25 28 15 50 25 60 150 1 25 32 28 45 100 50 110 150 1 5 40 28 50 140 6...

Отзывы: