6. Faults
CAUTION!
Physical injuries, damage to equipment
If faults cannot be eliminated by means of the measures listed, the
compression force transducer must be taken out of operation immediately.
▶
Contact the manufacturer.
▶
If a return is needed, please follow the instructions given in chapter 8.2
“Return”.
For contact details see chapter 1 “General information” or the back page
of the operating instructions.
Faults
Causes
Measures
No output signal
No or wrong supply voltage,
current pulse
Rectify the supply voltage
Cable break
Check the continuity
No or wrong output signal
Wrong cable assignment
Check cable assignment
Deviating zero point signal
Overload, load offset, wrong
connection
Consult the manufacturer
Constant output signal when
changing force
Wrong cable assignment
Check cable assignment
Mechanical overload
Consult the manufacturer
Signal span varies
EMC interference sources
in the environment, e.g.,
frequency converter
Shield instrument; cable
shielding; remove source of
interference
Signal span drops/too small
Mechanical overloading
Consult the manufacturer
Defective instruments must be returned to the manufacturer.
5. Commissioning, operation / 6. Faults
Electrical connection
Excitation voltage
(Exc+)
Green
Excitation voltage
(Exc-)
Black
Signal (Sig+)
Red
Signal (Sig-)
White
Shield
Shield
Cable pin assignment
Exc+
Sig+
Exc-
Sig-
Exc+ (green)
Shield
Sig+ (red)
Exc- (black)
Sig- (white)