EN
WIKA operating instructions digital indicator, model DI32-1
53
14122699.03 03/2020 EN/DE
13. Switching outputs
This chapter leads you through the parameters, step by step. Therefore, the
sub-chapters should be worked through in sequence. Dashed lines in the
diagrams indicate parameters that are skipped.
The menu navigation is arranged in such a sequence that first switching output 1
must be set and subsequently switching output 2. In the following sub-chapters the
parameters will all be described together since they behave in the same way and
are carried out in the same logical sequence.
→ Complete menu tree from page 57
13.1 Selecting the switching function
Parameter
Description
oFF
Switching output without function
There are no parameters that can be set
on
The switching output is switched permanently in measuring mode
Only the parameters “Ax.Er” and “Ax.tY” can be set
HI.LI
Switches when the switching threshold is exceeded
Lo.LI
Switches when measured value drops below the switching threshold
rAnG
Switches within the switching window (window function)
Out.r
Switches outside of the switching window (window function)
TYPE
A1.Fu
A2.Fu
[
▲
] [
▼
]
off
on
[
☼
]
[
▲
]
[
▼
]
[
☼
]
HI.LI
Lo.LI
rAnG
Out.r
13. Switching outputs