EN
WIKA operating instructions digital indicator, model DI32-1
28
14122699.03 03/2020 EN/DE
7. Voltage or current measurement
TYPE
VOLT
[
☼
]
0
…
10
[
☼
]
0
…
2
0
…
1
0
…
50
AMPE
[
▲
] [
▼
]
0
…
20
[
☼
]
4
…
20
End
[
▲
] [
▼
]
-1999
…
9999
[
☼
]
OFFS
[
▲
] [
▼
]
-1999
…
9999
[
☼
]
dot.A
[
▲
] [
▼
]
0000
…
0.000
[
☼
]
EndA
[
▲
] [
▼
]
-19.99
…
99.99
[
☼
]
OFFA
[
▲
] [
▼
]
-19.99
…
99.99
[
☼
]
tArA
[
▲
] [
▼
]
-1999
…
9999
[
☼
]
ZErO
[
▲
] [
▼
]
00
…
99
[
☼
]
OUEr
[
▲
] [
▼
]
no
[
☼
]
AdC
rAnG
5Pr
10Pr
SPC.A
[
▲
] [
▼
]
0
…
5
[
☼
]
dIS.1
[
▲
] [
▼
]
-1999
…
9999
[
☼
]
InP.1
[
▲
] [
▼
]
-1999
…
9999
[
☼
]
dIS.5
[
▲
] [
▼
]
-1999
…
999
[
☼
]
InP.5
[
▲
] [
▼
]
-1999
…
9999
[
☼
]
General settings
[
☼
]
[
▲
]
[
▼
]
[
▲
]
[
▼
]
[
▲
]
[
▼
]
[
☼
]
Input signal *
End of measuring range
Indication range *
Start of measuring range
Indication range *
Decimal places
End of measuring range
Input signal
Start of measuring range
Input signal
Offset adjustment
Zero point suppression
Overrun and underrun
behaviour
Number of
programmable points
Indications value
Programmable point 1
Analogue value
Programmable point 1
Indications value
Programmable point 5
Analogue value
Programmable point 5
* Required parameter