WIKA operating instructions attachable indicator model A-IAI-1
24
EN
14016825.04 07/2021 EN/DE
9. Specifications
Specifications
Temperature effect on the
indication
0.1 % / 10 K
Safety-related maximum values
Supply voltage
U
i = DC 9 ... 28 V
Short-circuit current
I
i = 100 mA
Power limitation
P
i = 1,200 mW
Maximum effective internal
capacitance
C
i
< 13 nF
Maximum effective internal
inductance
negligibly small
For further specifications see WIKA data sheet AC 80.07 and the order documentation.
Dimensions in mm