![WIKA 232.30 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/wika/232-30/232-30_additional-operating-instructions_980144017.webp)
EN
9. Specifications
17
14525888.01 04/2022 EN/DE/FR/ES
WIKA additional operating instructions for EMICOgauge
9. Specifications
Basic information for pressure gauges
Scale range
Between 0 ... 0.6 bar and 0 ... 420 bar
[0 ... 10 psi and 0 ... 6,000 psi]
As well as corresponding measuring spans for other units and
+/- scale ranges
Connection location
Lower mount (radial)
Assembly
Mounting type
EMICOgauge connection: 360° swivel connection (swivel
adapter) with special pressure sealing
Spare part: 5 x sealing set consisting of O-ring and support
ring; article no. 14525042
Instrumentation valve
■
For instrument version of IVM → See data sheet AC 09.17
■
Model IV10, IV11 or IV20 → See data sheets AC 09.22 and
AC 09.19
Operating conditions
Medium temperature
With unfilled pressure gauge
-20 ... +150 °C [-4 ... +302 °F]
With filled pressure gauge
-20 ... +100 °C [-4 ... +212 °F]
Ambient temperature
-20 ... +60 °C [-4 ... +140 °F]
Leak tightness of the overall
system
Fulfills the fugitive emission requirements
per TA Luft (VDI 2440), helium tested,
specific leakage rate: < 1∙10
-4
mbar l/m s
Содержание 232.30
Страница 18: ...WIKA additional operating instructions for EMICOgauge 18 14525888 01 04 2022 EN DE FR ES...
Страница 34: ...WIKA additional operating instructions for EMICOgauge 34 14525888 01 04 2022 EN DE FR ES...
Страница 50: ...FR 50 11532319 05 04 2019 EN DE FR ES Mode d emploi compl mentaires pour EMICOgauge...
Страница 66: ...WIKA additional operating instructions for EMICOgauge 66 14525888 01 04 2022 EN DE FR ES...
Страница 67: ...WIKA additional operating instructions for EMICOgauge 67 14525888 01 04 2022 EN DE FR ES...