10
2.2.2 Commissioning the K60 stationary box rotator
1.
To move the machine, first attach the transport hooks to the rotating frame. Set the lift truck forks so that
the points engage under the transport hooks. Drive carefully and take account of the width and height of the
machine.
2.
Slide the height adjuster to the correct box height, which must be 2 cm higher than the total box height.
Fasten the box support using the bolts
.
3.
Depending on the desired outflow opening, the left and right valves, the arm and the tipping frame can be
adjusted using the handles and bolts
.
4.
Subsequently check that the hydraulic hoses and electric cables can move freely and check that the system is
not leaking oil.
5.
Check the correct operation of the stationary rotator by operating the hydraulic functions.
The WIFO stationary box rotator is now ready for use.
Attach the hydraulic hose to a suitable hydraulic installation with a maximum pressure of 15 Mpa
(150 bar). The maximal pressure of 15 Mpa (150 bar) must not be exceeded.
ATTENTION:
Account must be taken of the correct direction of rotation of the generator when connecting it to
the power supply. Where this is incorrect, the two phases should be switched around.
Where the K60 is set up as a fixed installation it is recommended that it be secured using four
anchors in the floor.