4.7 ARC Control
If there is no arc detected for more than 3 seconds during active welding the inverter will be
automatically switched off.
This feature may prevent user from some desired actions. In case of feeding the wire in the
torch, please use Manual feed mode described before.
4.8 Factory setup
With the following procedure the machine can be reset to factory setup.
This procedure will delete all stored job an will reset all parameters to the state at delivery!
Make sure that the machine is conected to the power
supply and switched off.
Hold this button depressed and switch the machine on
until the initial display test sequence is over and the code
menu is displayed.
Once in the code menu you will have to enter the
unique code U 01, A 01, B 01, C 01. Individual
numbers can be accessed by pressing voltage
encoder.
When you have entered all 4 numbers and you are sure
that they are correct then confirm the complete code by
depression of this button. The panel will be restarted in
order to apply new factory default settings.